The hypothermic action of epidural and subarachnoid morphine in parturients

Sivam Ramanathan, Ellen H. Kavee, Jeffrey Bernstein, Mark I. Zakowski

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

Sublingual body temperatures were measured before and at 0.5,1,2,3,4,8,12, and 24 hours after administration of epidural or subarachnoid morphine in four groups of patients (n = 15 in each group) undergoing cesarean delivery with regional anesthesia. All patients were acutely hydrated with 1200 ml warmed lactated Ringer’s solution. Group 1 received 5 mg epidural morphine; Group 2,5 ml epidural saline; Group 3, 0.5 mg subarachnoid morphine, and Group 4,0.5 ml subarachnoid saline. The results were expressed as means ± SEM and analyzed using analysis of variance at p < 0.05. Body temperature decreased significantly in all the four groups after anes-thesia. The maximum decreases in Groups 1, 2, 3, and 4, respectively, were 0.95 ± 0.1, 0.9 ± 0.1, 1.4 ± 0.2, and 0.8 ± 0.13°C and occurred at 0.5, 1, 2, and 1 hour, respectively. The decrease was greater in the subarachnoid morphine group than in the other groups (p < 0.03). At any of the measurement periods, the temperatures in the two epidural groups did not differ from each other. However, the temperature in the subarachnoid morphine group remained significantly lower than the corresponding temperature in the control group for up to 24 hours. It is concluded that subarachnoid morphine intensifies the hypothermic action of spinal anesthesia in parturients.

Original languageEnglish (US)
Pages (from-to)325-328
Number of pages4
JournalRegional Anesthesia
Volume16
Issue number6
StatePublished - 1991
Externally publishedYes

Fingerprint

Morphine
Parturition
Body Temperature
Temperature
Conduction Anesthesia
Spinal Anesthesia
Analysis of Variance
Control Groups

Keywords

  • Body temperature
  • Epidural anesthesia
  • Epidural morphine
  • Spinal anesthesia
  • Subarachnoid morphine

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Ramanathan, S., Kavee, E. H., Bernstein, J., & Zakowski, M. I. (1991). The hypothermic action of epidural and subarachnoid morphine in parturients. Regional Anesthesia, 16(6), 325-328.

The hypothermic action of epidural and subarachnoid morphine in parturients. / Ramanathan, Sivam; Kavee, Ellen H.; Bernstein, Jeffrey; Zakowski, Mark I.

In: Regional Anesthesia, Vol. 16, No. 6, 1991, p. 325-328.

Research output: Contribution to journalArticle

Ramanathan, S, Kavee, EH, Bernstein, J & Zakowski, MI 1991, 'The hypothermic action of epidural and subarachnoid morphine in parturients', Regional Anesthesia, vol. 16, no. 6, pp. 325-328.
Ramanathan, Sivam ; Kavee, Ellen H. ; Bernstein, Jeffrey ; Zakowski, Mark I. / The hypothermic action of epidural and subarachnoid morphine in parturients. In: Regional Anesthesia. 1991 ; Vol. 16, No. 6. pp. 325-328.
@article{9ad667a0a59346d5aa0b7e820ea942f0,
title = "The hypothermic action of epidural and subarachnoid morphine in parturients",
abstract = "Sublingual body temperatures were measured before and at 0.5,1,2,3,4,8,12, and 24 hours after administration of epidural or subarachnoid morphine in four groups of patients (n = 15 in each group) undergoing cesarean delivery with regional anesthesia. All patients were acutely hydrated with 1200 ml warmed lactated Ringer’s solution. Group 1 received 5 mg epidural morphine; Group 2,5 ml epidural saline; Group 3, 0.5 mg subarachnoid morphine, and Group 4,0.5 ml subarachnoid saline. The results were expressed as means ± SEM and analyzed using analysis of variance at p < 0.05. Body temperature decreased significantly in all the four groups after anes-thesia. The maximum decreases in Groups 1, 2, 3, and 4, respectively, were 0.95 ± 0.1, 0.9 ± 0.1, 1.4 ± 0.2, and 0.8 ± 0.13°C and occurred at 0.5, 1, 2, and 1 hour, respectively. The decrease was greater in the subarachnoid morphine group than in the other groups (p < 0.03). At any of the measurement periods, the temperatures in the two epidural groups did not differ from each other. However, the temperature in the subarachnoid morphine group remained significantly lower than the corresponding temperature in the control group for up to 24 hours. It is concluded that subarachnoid morphine intensifies the hypothermic action of spinal anesthesia in parturients.",
keywords = "Body temperature, Epidural anesthesia, Epidural morphine, Spinal anesthesia, Subarachnoid morphine",
author = "Sivam Ramanathan and Kavee, {Ellen H.} and Jeffrey Bernstein and Zakowski, {Mark I.}",
year = "1991",
language = "English (US)",
volume = "16",
pages = "325--328",
journal = "Regional Anesthesia and Pain Medicine",
issn = "1098-7339",
publisher = "Lippincott Williams and Wilkins",
number = "6",

}

TY - JOUR

T1 - The hypothermic action of epidural and subarachnoid morphine in parturients

AU - Ramanathan, Sivam

AU - Kavee, Ellen H.

AU - Bernstein, Jeffrey

AU - Zakowski, Mark I.

PY - 1991

Y1 - 1991

N2 - Sublingual body temperatures were measured before and at 0.5,1,2,3,4,8,12, and 24 hours after administration of epidural or subarachnoid morphine in four groups of patients (n = 15 in each group) undergoing cesarean delivery with regional anesthesia. All patients were acutely hydrated with 1200 ml warmed lactated Ringer’s solution. Group 1 received 5 mg epidural morphine; Group 2,5 ml epidural saline; Group 3, 0.5 mg subarachnoid morphine, and Group 4,0.5 ml subarachnoid saline. The results were expressed as means ± SEM and analyzed using analysis of variance at p < 0.05. Body temperature decreased significantly in all the four groups after anes-thesia. The maximum decreases in Groups 1, 2, 3, and 4, respectively, were 0.95 ± 0.1, 0.9 ± 0.1, 1.4 ± 0.2, and 0.8 ± 0.13°C and occurred at 0.5, 1, 2, and 1 hour, respectively. The decrease was greater in the subarachnoid morphine group than in the other groups (p < 0.03). At any of the measurement periods, the temperatures in the two epidural groups did not differ from each other. However, the temperature in the subarachnoid morphine group remained significantly lower than the corresponding temperature in the control group for up to 24 hours. It is concluded that subarachnoid morphine intensifies the hypothermic action of spinal anesthesia in parturients.

AB - Sublingual body temperatures were measured before and at 0.5,1,2,3,4,8,12, and 24 hours after administration of epidural or subarachnoid morphine in four groups of patients (n = 15 in each group) undergoing cesarean delivery with regional anesthesia. All patients were acutely hydrated with 1200 ml warmed lactated Ringer’s solution. Group 1 received 5 mg epidural morphine; Group 2,5 ml epidural saline; Group 3, 0.5 mg subarachnoid morphine, and Group 4,0.5 ml subarachnoid saline. The results were expressed as means ± SEM and analyzed using analysis of variance at p < 0.05. Body temperature decreased significantly in all the four groups after anes-thesia. The maximum decreases in Groups 1, 2, 3, and 4, respectively, were 0.95 ± 0.1, 0.9 ± 0.1, 1.4 ± 0.2, and 0.8 ± 0.13°C and occurred at 0.5, 1, 2, and 1 hour, respectively. The decrease was greater in the subarachnoid morphine group than in the other groups (p < 0.03). At any of the measurement periods, the temperatures in the two epidural groups did not differ from each other. However, the temperature in the subarachnoid morphine group remained significantly lower than the corresponding temperature in the control group for up to 24 hours. It is concluded that subarachnoid morphine intensifies the hypothermic action of spinal anesthesia in parturients.

KW - Body temperature

KW - Epidural anesthesia

KW - Epidural morphine

KW - Spinal anesthesia

KW - Subarachnoid morphine

UR - http://www.scopus.com/inward/record.url?scp=0026249845&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026249845&partnerID=8YFLogxK

M3 - Article

VL - 16

SP - 325

EP - 328

JO - Regional Anesthesia and Pain Medicine

JF - Regional Anesthesia and Pain Medicine

SN - 1098-7339

IS - 6

ER -