TY - JOUR
T1 - Primary results of long-term outcomes in the MOMENTUM 3 pivotal trial and continued access protocol study phase
T2 - a study of 2200 HeartMate 3 left ventricular assist device implants
AU - On behalf of the MOMENTUM 3 Investigators
AU - Mehra, Mandeep R.
AU - Cleveland, Joseph C.
AU - Uriel, Nir
AU - Cowger, Jennifer A.
AU - Hall, Shelley
AU - Horstmanshof, Douglas
AU - Naka, Yoshifumi
AU - Salerno, Christopher T.
AU - Chuang, Joyce
AU - Williams, Christopher
AU - Goldstein, Daniel J.
N1 - Funding Information:
Both MOMENTUM 3 Pivotal and CAP studies were sponsored by Abbott. The HeartMate 3 left ventricular assist system is manufactured by Abbott. Conflict of interest: M.R.M.: payment made to institution from Abbott for consulting. Consulting fees from Mesoblast, Janssen, Portola, Bayer, Triple Gene, and Baim Institute for Clinical Research. Advisory board member for NuPulseCV, Leviticus and FineHeart. J.C.C.: grant support from Abbott. N.U.: grant support and consultant fees from Abbott and Medtronic. J.A.C.: consultant and speaker for Abbott and Medtronic. On steering committee/study panel for Medtronic, Abbott and Procyrion. Henry Ford receives institutional funds from Abbott, Medtronic and Procyrion. S.H.: speaker's bureau fees from CareDx. Consultant fees from Abbott, Abiomed, Medtronic, CareDx and Natera. D.H.: consultant and speaker's bureau fees from Abbott. Y.N.: consultant fees from Abbott. C.T.S.: consultant fees from Abbott and Medtronic. J.C. and C.W.: employees of Abbott. D.J.G.: educator and surgical proctor for Abbott; consultant for Abiomed. The authors would like to thank all the patients, our investigators, clinical nurse coordinators, and allied health personnel for their dedication to the conduct of the MOMENTUM 3 studies. Both MOMENTUM 3 Pivotal and CAP studies were sponsored by Abbott. The HeartMate 3 left ventricular assist system is manufactured by Abbott. Conflict of interest: M.R.M.: payment made to institution from Abbott for consulting. Consulting fees from Mesoblast, Janssen, Portola, Bayer, Triple Gene, and Baim Institute for Clinical Research. Advisory board member for NuPulseCV, Leviticus and FineHeart. J.C.C.: grant support from Abbott. N.U.: grant support and consultant fees from Abbott and Medtronic. J.A.C.: consultant and speaker for Abbott and Medtronic. On steering committee/study panel for Medtronic, Abbott and Procyrion. Henry Ford receives institutional funds from Abbott, Medtronic and Procyrion. S.H.: speaker's bureau fees from CareDx. Consultant fees from Abbott, Abiomed, Medtronic, CareDx and Natera. D.H.: consultant and speaker's bureau fees from Abbott. Y.N.: consultant fees from Abbott. C.T.S.: consultant fees from Abbott and Medtronic. J.C. and C.W.: employees of Abbott. D.J.G.: educator and surgical proctor for Abbott; consultant for Abiomed.
Funding Information:
: M.R.M.: payment made to institution from Abbott for consulting. Consulting fees from Mesoblast, Janssen, Portola, Bayer, Triple Gene, and Baim Institute for Clinical Research. Advisory board member for NuPulseCV, Leviticus and FineHeart. J.C.C.: grant support from Abbott. N.U.: grant support and consultant fees from Abbott and Medtronic. J.A.C.: consultant and speaker for Abbott and Medtronic. On steering committee/study panel for Medtronic, Abbott and Procyrion. Henry Ford receives institutional funds from Abbott, Medtronic and Procyrion. S.H.: speaker's bureau fees from CareDx. Consultant fees from Abbott, Abiomed, Medtronic, CareDx and Natera. D.H.: consultant and speaker's bureau fees from Abbott. Y.N.: consultant fees from Abbott. C.T.S.: consultant fees from Abbott and Medtronic. J.C. and C.W.: employees of Abbott. D.J.G.: educator and surgical proctor for Abbott; consultant for Abiomed. Conflict of interest
Publisher Copyright:
© 2021 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.
PY - 2021/8
Y1 - 2021/8
N2 - Aim: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal-flow pump, over the HeartMate II axial-flow pump. We now evaluate HM3 LVAD outcomes in a single-arm prospective continuous access protocol (CAP) post-pivotal trial study. Methods and results: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2-year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71–1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra-aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68–1.16, P = 0.38). In a pooled analysis, the 2-year primary endpoint was similar between INTERMACS profiles 1–2 (‘unstable’ advanced heart failure), profile 3 (‘stable’ on inotropic therapy), and profiles 4–7 (‘stable’ ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88–0.98, P = 0.006), with consequent decrease in hospitalization. Conclusions: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial.
AB - Aim: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal-flow pump, over the HeartMate II axial-flow pump. We now evaluate HM3 LVAD outcomes in a single-arm prospective continuous access protocol (CAP) post-pivotal trial study. Methods and results: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2-year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71–1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra-aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68–1.16, P = 0.38). In a pooled analysis, the 2-year primary endpoint was similar between INTERMACS profiles 1–2 (‘unstable’ advanced heart failure), profile 3 (‘stable’ on inotropic therapy), and profiles 4–7 (‘stable’ ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88–0.98, P = 0.006), with consequent decrease in hospitalization. Conclusions: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial.
KW - Advanced heart failure
KW - Clinical trial
KW - Learning curve
KW - Left ventricular assist device
KW - MOMENTUM 3
KW - Outcome
UR - http://www.scopus.com/inward/record.url?scp=85106322799&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85106322799&partnerID=8YFLogxK
U2 - 10.1002/ejhf.2211
DO - 10.1002/ejhf.2211
M3 - Article
C2 - 33932272
AN - SCOPUS:85106322799
SN - 1388-9842
VL - 23
SP - 1392
EP - 1400
JO - European Journal of Heart Failure
JF - European Journal of Heart Failure
IS - 8
ER -