Packaging architecture for an implanted system that monitors brain activity and applies therapeutic stimulation

Caroline K. Bjune, Thomas F. Marinis, Tirunelveli S. Sriram, Jeanne M. Brady, James Moran, Philip D. Parks, Alik S. Widge, Darin D. Dougherty, Emad N. Eskandar

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Deep brain stimulation therapies for Parkinson's disease utilize hardware that, from a packaging perspective, resembles those that are used in cardiac pacemakers. A hermetic package that contains stimulation electronics and a primary battery supply is implanted under the scalp into a recess formed in the skull. Stimulation probes, each with up to four electrodes, are inserted into the brain and connected to the electronics package via a plug and cable system. Unlike single-target devices such as cochlear implants and pacemakers, achieving this type of neuropsychiatric therapy requires the ability to record and stimulate in multiple and distributive areas of the brain, both cortical and subcortical. By contrast, the closed-loop neural stimulator being developed under the DARPA SUBNETS program utilizes probes, each of which carries up to 64 electrodes that can be switched between recording and stimulation functions. This capability necessitates locating low-noise amplifiers, switching and communication electronics in close proximity to each probe site. Each of these satellite electronics packages requires 10 electrical connections to the hub package, which significantly increases the complexity of the interconnect system relative to the current practice. The power requirements of this system preclude the use of a primary battery supply, so a large lithium ion battery is used, with a recharging coil and electronics. The hub system is composed of a connector header, electronics package, and battery pack that are fabricated separately and are interconnected by a flex circuit board, to allow it to conform to the skull for implanting. The standardized feedthrough substrate on the satellite, which can interface with multiple types of electrodes, along the system being reconfigurable, enables our architecture to support this new clinical research. It also allows the clinician to select satellite-electrode system based on a patient's needs, thus providing a customized, patient-specific therapeutic system. In this article, we have described the various packaging components of this system and the design considerations that drove our technology choices.

Original languageEnglish (US)
Pages (from-to)64-70
Number of pages7
JournalJournal of Microelectronics and Electronic Packaging
Volume13
Issue number2
DOIs
StatePublished - Apr 1 2016
Externally publishedYes

Fingerprint

Brain
Packaging
Electronic equipment
Primary batteries
Pacemakers
Electrodes
Satellites
Cochlear implants
Low noise amplifiers
Cables
Hardware
Networks (circuits)
Communication
Substrates

Keywords

  • Closed-loop system
  • Distributive architecture
  • Implantable systems
  • Neural stimulator

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Computer Networks and Communications
  • Electrical and Electronic Engineering

Cite this

Packaging architecture for an implanted system that monitors brain activity and applies therapeutic stimulation. / Bjune, Caroline K.; Marinis, Thomas F.; Sriram, Tirunelveli S.; Brady, Jeanne M.; Moran, James; Parks, Philip D.; Widge, Alik S.; Dougherty, Darin D.; Eskandar, Emad N.

In: Journal of Microelectronics and Electronic Packaging, Vol. 13, No. 2, 01.04.2016, p. 64-70.

Research output: Contribution to journalArticle

Bjune, Caroline K. ; Marinis, Thomas F. ; Sriram, Tirunelveli S. ; Brady, Jeanne M. ; Moran, James ; Parks, Philip D. ; Widge, Alik S. ; Dougherty, Darin D. ; Eskandar, Emad N. / Packaging architecture for an implanted system that monitors brain activity and applies therapeutic stimulation. In: Journal of Microelectronics and Electronic Packaging. 2016 ; Vol. 13, No. 2. pp. 64-70.
@article{2e552005659144beb1b00347af19bb98,
title = "Packaging architecture for an implanted system that monitors brain activity and applies therapeutic stimulation",
abstract = "Deep brain stimulation therapies for Parkinson's disease utilize hardware that, from a packaging perspective, resembles those that are used in cardiac pacemakers. A hermetic package that contains stimulation electronics and a primary battery supply is implanted under the scalp into a recess formed in the skull. Stimulation probes, each with up to four electrodes, are inserted into the brain and connected to the electronics package via a plug and cable system. Unlike single-target devices such as cochlear implants and pacemakers, achieving this type of neuropsychiatric therapy requires the ability to record and stimulate in multiple and distributive areas of the brain, both cortical and subcortical. By contrast, the closed-loop neural stimulator being developed under the DARPA SUBNETS program utilizes probes, each of which carries up to 64 electrodes that can be switched between recording and stimulation functions. This capability necessitates locating low-noise amplifiers, switching and communication electronics in close proximity to each probe site. Each of these satellite electronics packages requires 10 electrical connections to the hub package, which significantly increases the complexity of the interconnect system relative to the current practice. The power requirements of this system preclude the use of a primary battery supply, so a large lithium ion battery is used, with a recharging coil and electronics. The hub system is composed of a connector header, electronics package, and battery pack that are fabricated separately and are interconnected by a flex circuit board, to allow it to conform to the skull for implanting. The standardized feedthrough substrate on the satellite, which can interface with multiple types of electrodes, along the system being reconfigurable, enables our architecture to support this new clinical research. It also allows the clinician to select satellite-electrode system based on a patient's needs, thus providing a customized, patient-specific therapeutic system. In this article, we have described the various packaging components of this system and the design considerations that drove our technology choices.",
keywords = "Closed-loop system, Distributive architecture, Implantable systems, Neural stimulator",
author = "Bjune, {Caroline K.} and Marinis, {Thomas F.} and Sriram, {Tirunelveli S.} and Brady, {Jeanne M.} and James Moran and Parks, {Philip D.} and Widge, {Alik S.} and Dougherty, {Darin D.} and Eskandar, {Emad N.}",
year = "2016",
month = "4",
day = "1",
doi = "10.4071/imaps.499",
language = "English (US)",
volume = "13",
pages = "64--70",
journal = "The International journal for hybrid microelectronics",
issn = "1551-4897",
publisher = "IMAPS-International Microelectronics and Packaging Society",
number = "2",

}

TY - JOUR

T1 - Packaging architecture for an implanted system that monitors brain activity and applies therapeutic stimulation

AU - Bjune, Caroline K.

AU - Marinis, Thomas F.

AU - Sriram, Tirunelveli S.

AU - Brady, Jeanne M.

AU - Moran, James

AU - Parks, Philip D.

AU - Widge, Alik S.

AU - Dougherty, Darin D.

AU - Eskandar, Emad N.

PY - 2016/4/1

Y1 - 2016/4/1

N2 - Deep brain stimulation therapies for Parkinson's disease utilize hardware that, from a packaging perspective, resembles those that are used in cardiac pacemakers. A hermetic package that contains stimulation electronics and a primary battery supply is implanted under the scalp into a recess formed in the skull. Stimulation probes, each with up to four electrodes, are inserted into the brain and connected to the electronics package via a plug and cable system. Unlike single-target devices such as cochlear implants and pacemakers, achieving this type of neuropsychiatric therapy requires the ability to record and stimulate in multiple and distributive areas of the brain, both cortical and subcortical. By contrast, the closed-loop neural stimulator being developed under the DARPA SUBNETS program utilizes probes, each of which carries up to 64 electrodes that can be switched between recording and stimulation functions. This capability necessitates locating low-noise amplifiers, switching and communication electronics in close proximity to each probe site. Each of these satellite electronics packages requires 10 electrical connections to the hub package, which significantly increases the complexity of the interconnect system relative to the current practice. The power requirements of this system preclude the use of a primary battery supply, so a large lithium ion battery is used, with a recharging coil and electronics. The hub system is composed of a connector header, electronics package, and battery pack that are fabricated separately and are interconnected by a flex circuit board, to allow it to conform to the skull for implanting. The standardized feedthrough substrate on the satellite, which can interface with multiple types of electrodes, along the system being reconfigurable, enables our architecture to support this new clinical research. It also allows the clinician to select satellite-electrode system based on a patient's needs, thus providing a customized, patient-specific therapeutic system. In this article, we have described the various packaging components of this system and the design considerations that drove our technology choices.

AB - Deep brain stimulation therapies for Parkinson's disease utilize hardware that, from a packaging perspective, resembles those that are used in cardiac pacemakers. A hermetic package that contains stimulation electronics and a primary battery supply is implanted under the scalp into a recess formed in the skull. Stimulation probes, each with up to four electrodes, are inserted into the brain and connected to the electronics package via a plug and cable system. Unlike single-target devices such as cochlear implants and pacemakers, achieving this type of neuropsychiatric therapy requires the ability to record and stimulate in multiple and distributive areas of the brain, both cortical and subcortical. By contrast, the closed-loop neural stimulator being developed under the DARPA SUBNETS program utilizes probes, each of which carries up to 64 electrodes that can be switched between recording and stimulation functions. This capability necessitates locating low-noise amplifiers, switching and communication electronics in close proximity to each probe site. Each of these satellite electronics packages requires 10 electrical connections to the hub package, which significantly increases the complexity of the interconnect system relative to the current practice. The power requirements of this system preclude the use of a primary battery supply, so a large lithium ion battery is used, with a recharging coil and electronics. The hub system is composed of a connector header, electronics package, and battery pack that are fabricated separately and are interconnected by a flex circuit board, to allow it to conform to the skull for implanting. The standardized feedthrough substrate on the satellite, which can interface with multiple types of electrodes, along the system being reconfigurable, enables our architecture to support this new clinical research. It also allows the clinician to select satellite-electrode system based on a patient's needs, thus providing a customized, patient-specific therapeutic system. In this article, we have described the various packaging components of this system and the design considerations that drove our technology choices.

KW - Closed-loop system

KW - Distributive architecture

KW - Implantable systems

KW - Neural stimulator

UR - http://www.scopus.com/inward/record.url?scp=85021125009&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021125009&partnerID=8YFLogxK

U2 - 10.4071/imaps.499

DO - 10.4071/imaps.499

M3 - Article

AN - SCOPUS:85021125009

VL - 13

SP - 64

EP - 70

JO - The International journal for hybrid microelectronics

JF - The International journal for hybrid microelectronics

SN - 1551-4897

IS - 2

ER -