Intrinsic conduction maximizes cardiopulmonary performance in patients with dual chamber pacemakers

G. R. Harper, Ileana L. Pina, S. P. Kutalek

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

Dual chamber pacemaker programmability allows the possibility of atrially- tracked ventricular pacing in patients who would otherwise have intrinsic atrioventricular (AV) conduction. Thirteen patients with permanent AV sequential pacemakers (ages 50-79) were evaluated with paired exercise tests to determine the cardiopulmonary effects of pacemaker induced right ventricular activation compared with normal AV and intraventricular conduction. Peak oxygen uptake (VO2), oxygen pulse (O2P), respiratory rate (RR), and respiratory exchange ratio (RER) were determined using breath-by- breath analysis of expired gases. Patients exercised to fatigue and exercise tests were performed in random sequence. For patients with intrinsic AV conduction (group I, n = 8) the AV delay was programmed to preserve intrinsic conduction during one study; the alternate test used AV delay programming to produce ventricular pacing. Five patients with chronic AV block (group II) acted as a control for the effects of a rate adaptive AV delay compared to a fixed AV delay. Paired t-testing showed a significantly lower peak VO2 (P < 0.015) and O2P (P < 0.01) in patients with atrially-tracked ventricular pacing compared to intrinsic conduction. In contrast, group II showed a significant improvement in peak VO2 with rate adaptive AV delay compared to fixed AV delay programming (P < 0.05). In conclusion, intrinsic conduction should be preserved in patients with dual chamber pacemakers whenever possible.

Original languageEnglish (US)
Pages (from-to)1787-1791
Number of pages5
JournalPACE - Pacing and Clinical Electrophysiology
Volume14
Issue number11 II
StatePublished - 1991
Externally publishedYes

Fingerprint

Exercise Test
Oxygen
Atrioventricular Block
Respiratory Rate
Fatigue
Gases

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Intrinsic conduction maximizes cardiopulmonary performance in patients with dual chamber pacemakers. / Harper, G. R.; Pina, Ileana L.; Kutalek, S. P.

In: PACE - Pacing and Clinical Electrophysiology, Vol. 14, No. 11 II, 1991, p. 1787-1791.

Research output: Contribution to journalArticle

Harper, G. R. ; Pina, Ileana L. ; Kutalek, S. P. / Intrinsic conduction maximizes cardiopulmonary performance in patients with dual chamber pacemakers. In: PACE - Pacing and Clinical Electrophysiology. 1991 ; Vol. 14, No. 11 II. pp. 1787-1791.
@article{9dd5ed27b7d54df09dbae159961e78e1,
title = "Intrinsic conduction maximizes cardiopulmonary performance in patients with dual chamber pacemakers",
abstract = "Dual chamber pacemaker programmability allows the possibility of atrially- tracked ventricular pacing in patients who would otherwise have intrinsic atrioventricular (AV) conduction. Thirteen patients with permanent AV sequential pacemakers (ages 50-79) were evaluated with paired exercise tests to determine the cardiopulmonary effects of pacemaker induced right ventricular activation compared with normal AV and intraventricular conduction. Peak oxygen uptake (VO2), oxygen pulse (O2P), respiratory rate (RR), and respiratory exchange ratio (RER) were determined using breath-by- breath analysis of expired gases. Patients exercised to fatigue and exercise tests were performed in random sequence. For patients with intrinsic AV conduction (group I, n = 8) the AV delay was programmed to preserve intrinsic conduction during one study; the alternate test used AV delay programming to produce ventricular pacing. Five patients with chronic AV block (group II) acted as a control for the effects of a rate adaptive AV delay compared to a fixed AV delay. Paired t-testing showed a significantly lower peak VO2 (P < 0.015) and O2P (P < 0.01) in patients with atrially-tracked ventricular pacing compared to intrinsic conduction. In contrast, group II showed a significant improvement in peak VO2 with rate adaptive AV delay compared to fixed AV delay programming (P < 0.05). In conclusion, intrinsic conduction should be preserved in patients with dual chamber pacemakers whenever possible.",
author = "Harper, {G. R.} and Pina, {Ileana L.} and Kutalek, {S. P.}",
year = "1991",
language = "English (US)",
volume = "14",
pages = "1787--1791",
journal = "PACE - Pacing and Clinical Electrophysiology",
issn = "0147-8389",
publisher = "Wiley-Blackwell",
number = "11 II",

}

TY - JOUR

T1 - Intrinsic conduction maximizes cardiopulmonary performance in patients with dual chamber pacemakers

AU - Harper, G. R.

AU - Pina, Ileana L.

AU - Kutalek, S. P.

PY - 1991

Y1 - 1991

N2 - Dual chamber pacemaker programmability allows the possibility of atrially- tracked ventricular pacing in patients who would otherwise have intrinsic atrioventricular (AV) conduction. Thirteen patients with permanent AV sequential pacemakers (ages 50-79) were evaluated with paired exercise tests to determine the cardiopulmonary effects of pacemaker induced right ventricular activation compared with normal AV and intraventricular conduction. Peak oxygen uptake (VO2), oxygen pulse (O2P), respiratory rate (RR), and respiratory exchange ratio (RER) were determined using breath-by- breath analysis of expired gases. Patients exercised to fatigue and exercise tests were performed in random sequence. For patients with intrinsic AV conduction (group I, n = 8) the AV delay was programmed to preserve intrinsic conduction during one study; the alternate test used AV delay programming to produce ventricular pacing. Five patients with chronic AV block (group II) acted as a control for the effects of a rate adaptive AV delay compared to a fixed AV delay. Paired t-testing showed a significantly lower peak VO2 (P < 0.015) and O2P (P < 0.01) in patients with atrially-tracked ventricular pacing compared to intrinsic conduction. In contrast, group II showed a significant improvement in peak VO2 with rate adaptive AV delay compared to fixed AV delay programming (P < 0.05). In conclusion, intrinsic conduction should be preserved in patients with dual chamber pacemakers whenever possible.

AB - Dual chamber pacemaker programmability allows the possibility of atrially- tracked ventricular pacing in patients who would otherwise have intrinsic atrioventricular (AV) conduction. Thirteen patients with permanent AV sequential pacemakers (ages 50-79) were evaluated with paired exercise tests to determine the cardiopulmonary effects of pacemaker induced right ventricular activation compared with normal AV and intraventricular conduction. Peak oxygen uptake (VO2), oxygen pulse (O2P), respiratory rate (RR), and respiratory exchange ratio (RER) were determined using breath-by- breath analysis of expired gases. Patients exercised to fatigue and exercise tests were performed in random sequence. For patients with intrinsic AV conduction (group I, n = 8) the AV delay was programmed to preserve intrinsic conduction during one study; the alternate test used AV delay programming to produce ventricular pacing. Five patients with chronic AV block (group II) acted as a control for the effects of a rate adaptive AV delay compared to a fixed AV delay. Paired t-testing showed a significantly lower peak VO2 (P < 0.015) and O2P (P < 0.01) in patients with atrially-tracked ventricular pacing compared to intrinsic conduction. In contrast, group II showed a significant improvement in peak VO2 with rate adaptive AV delay compared to fixed AV delay programming (P < 0.05). In conclusion, intrinsic conduction should be preserved in patients with dual chamber pacemakers whenever possible.

UR - http://www.scopus.com/inward/record.url?scp=0025789691&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025789691&partnerID=8YFLogxK

M3 - Article

C2 - 1721176

AN - SCOPUS:0025789691

VL - 14

SP - 1787

EP - 1791

JO - PACE - Pacing and Clinical Electrophysiology

JF - PACE - Pacing and Clinical Electrophysiology

SN - 0147-8389

IS - 11 II

ER -