Image-guided endoscopic surgery

Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system

Marvin P. Fried, Jonathan Kleefield, Harsha Gopal, Edward Reardon, Bryan T. Ho, Frederick A. Kuhn

Research output: Contribution to journalArticle

Abstract

Image-guided surgery has recently been described in the literature as a useflil technology for improved functional endoscopic sinus surgery localization. Image-guided surgery yields accurate knowledge of the surgical field boundaries, allowing safer and more thorough sinus surgery. We have previously reviewed our initial experience with The InstaTrak System. This article presents a multicenter clinical study (n=55) that assesses the system's capability for localizing structures in critical surgical sites. The purpose of this paper is to present quantitative data on accuracy and performance. We describe several new advances including an automated registration technique that eliminates the redundant computed tomography scan, compensation for head movement, and the ability to use interchangeabic instruments.

Original languageEnglish (US)
Pages (from-to)774-781
Number of pages8
JournalLaryngoscope
Volume125
Issue number4
DOIs
StatePublished - Apr 1 2015
Externally publishedYes

Fingerprint

Computer-Assisted Surgery
Electromagnetic Phenomena
Multicenter Studies
Head Movements
Tomography
Technology
Clinical Studies

ASJC Scopus subject areas

  • Otorhinolaryngology
  • Medicine(all)

Cite this

Image-guided endoscopic surgery : Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system. / Fried, Marvin P.; Kleefield, Jonathan; Gopal, Harsha; Reardon, Edward; Ho, Bryan T.; Kuhn, Frederick A.

In: Laryngoscope, Vol. 125, No. 4, 01.04.2015, p. 774-781.

Research output: Contribution to journalArticle

Fried, Marvin P. ; Kleefield, Jonathan ; Gopal, Harsha ; Reardon, Edward ; Ho, Bryan T. ; Kuhn, Frederick A. / Image-guided endoscopic surgery : Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system. In: Laryngoscope. 2015 ; Vol. 125, No. 4. pp. 774-781.
@article{12d64d9c2d8d4eb3992d6d3174c5330f,
title = "Image-guided endoscopic surgery: Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system",
abstract = "Image-guided surgery has recently been described in the literature as a useflil technology for improved functional endoscopic sinus surgery localization. Image-guided surgery yields accurate knowledge of the surgical field boundaries, allowing safer and more thorough sinus surgery. We have previously reviewed our initial experience with The InstaTrak System. This article presents a multicenter clinical study (n=55) that assesses the system's capability for localizing structures in critical surgical sites. The purpose of this paper is to present quantitative data on accuracy and performance. We describe several new advances including an automated registration technique that eliminates the redundant computed tomography scan, compensation for head movement, and the ability to use interchangeabic instruments.",
author = "Fried, {Marvin P.} and Jonathan Kleefield and Harsha Gopal and Edward Reardon and Ho, {Bryan T.} and Kuhn, {Frederick A.}",
year = "2015",
month = "4",
day = "1",
doi = "10.1002/lary.25217",
language = "English (US)",
volume = "125",
pages = "774--781",
journal = "Laryngoscope",
issn = "0023-852X",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

TY - JOUR

T1 - Image-guided endoscopic surgery

T2 - Results of accuracy and performance in a multicenter clinical study using an electromagnetic tracking system

AU - Fried, Marvin P.

AU - Kleefield, Jonathan

AU - Gopal, Harsha

AU - Reardon, Edward

AU - Ho, Bryan T.

AU - Kuhn, Frederick A.

PY - 2015/4/1

Y1 - 2015/4/1

N2 - Image-guided surgery has recently been described in the literature as a useflil technology for improved functional endoscopic sinus surgery localization. Image-guided surgery yields accurate knowledge of the surgical field boundaries, allowing safer and more thorough sinus surgery. We have previously reviewed our initial experience with The InstaTrak System. This article presents a multicenter clinical study (n=55) that assesses the system's capability for localizing structures in critical surgical sites. The purpose of this paper is to present quantitative data on accuracy and performance. We describe several new advances including an automated registration technique that eliminates the redundant computed tomography scan, compensation for head movement, and the ability to use interchangeabic instruments.

AB - Image-guided surgery has recently been described in the literature as a useflil technology for improved functional endoscopic sinus surgery localization. Image-guided surgery yields accurate knowledge of the surgical field boundaries, allowing safer and more thorough sinus surgery. We have previously reviewed our initial experience with The InstaTrak System. This article presents a multicenter clinical study (n=55) that assesses the system's capability for localizing structures in critical surgical sites. The purpose of this paper is to present quantitative data on accuracy and performance. We describe several new advances including an automated registration technique that eliminates the redundant computed tomography scan, compensation for head movement, and the ability to use interchangeabic instruments.

UR - http://www.scopus.com/inward/record.url?scp=84925400679&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84925400679&partnerID=8YFLogxK

U2 - 10.1002/lary.25217

DO - 10.1002/lary.25217

M3 - Article

VL - 125

SP - 774

EP - 781

JO - Laryngoscope

JF - Laryngoscope

SN - 0023-852X

IS - 4

ER -