Evaluating an Image Gently and Image Wisely Campaign in a Multihospital Health Care System

Kevin Fernandes, Terry L. Levin, Todd S. Miller, Alan H. Schoenfeld, E. Stephen Amis

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

Purpose The efficacy of an Image Gently®/Image Wisely® radiology departmental campaign consisting of the optimization of CT protocols to reduce dose while maintaining quality, and an educational effort to alter the ordering patterns of referring physicians at a multihospital academic center, was evaluated. Methods The numbers of CT, MR, and ultrasound studies performed at inpatient, outpatient, and emergency facilities in the hospital system before and after the initiation of the departmental campaign (2010) were obtained for a 10-year period (2004-2014) using a radiology information system. For the same time period, dose per scan (volumetric CT dose index) was obtained through the Dose Index Registry®/National Radiology Data Registry for frequently performed studies. Descriptive statistics were used to analyze temporal trends in radiation dose and utilization across differing age groups: <20, 20 to 39, and 40 to 59 years. Results The radiology information system yielded 865,879 imaging examinations and 4,508,030 patients. Although patient and imaging volume grew annually over the study period (by 6.8% and 4.9%, respectively), CT utilization as a percentage of total imaging decreased, compensated for by an increase in ultrasound use. This was most marked in the youngest age group. MR use as a percentage of total imaging was unchanged. The median volumetric CT dose index for each study protocol was reduced or stabilized. Conclusions The campaign resulted in a reduction in CT utilization, a reduction in radiation dose per study, and a compensatory rise in ultrasound use. An interactive aggressive educational campaign directed toward referring providers combined with protocol dose reduction efforts can be successful in reducing patient exposure from medical radiation.

Original languageEnglish (US)
Pages (from-to)1010-1017
Number of pages8
JournalJournal of the American College of Radiology
Volume13
Issue number8
DOIs
StatePublished - Aug 1 2016

Fingerprint

Radiology Information Systems
Cone-Beam Computed Tomography
Delivery of Health Care
Radiology
Registries
Age Groups
Radiation
Inpatients
Emergencies
Outpatients
Physicians
CT protocol
Radiation Exposure

Keywords

  • computed tomography
  • dose
  • Image Gently
  • Image Wisely
  • Medical radiation

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Evaluating an Image Gently and Image Wisely Campaign in a Multihospital Health Care System. / Fernandes, Kevin; Levin, Terry L.; Miller, Todd S.; Schoenfeld, Alan H.; Amis, E. Stephen.

In: Journal of the American College of Radiology, Vol. 13, No. 8, 01.08.2016, p. 1010-1017.

Research output: Contribution to journalArticle

Fernandes, Kevin ; Levin, Terry L. ; Miller, Todd S. ; Schoenfeld, Alan H. ; Amis, E. Stephen. / Evaluating an Image Gently and Image Wisely Campaign in a Multihospital Health Care System. In: Journal of the American College of Radiology. 2016 ; Vol. 13, No. 8. pp. 1010-1017.
@article{82f80da302a64974b7865faa38905783,
title = "Evaluating an Image Gently and Image Wisely Campaign in a Multihospital Health Care System",
abstract = "Purpose The efficacy of an Image Gently{\circledR}/Image Wisely{\circledR} radiology departmental campaign consisting of the optimization of CT protocols to reduce dose while maintaining quality, and an educational effort to alter the ordering patterns of referring physicians at a multihospital academic center, was evaluated. Methods The numbers of CT, MR, and ultrasound studies performed at inpatient, outpatient, and emergency facilities in the hospital system before and after the initiation of the departmental campaign (2010) were obtained for a 10-year period (2004-2014) using a radiology information system. For the same time period, dose per scan (volumetric CT dose index) was obtained through the Dose Index Registry{\circledR}/National Radiology Data Registry for frequently performed studies. Descriptive statistics were used to analyze temporal trends in radiation dose and utilization across differing age groups: <20, 20 to 39, and 40 to 59 years. Results The radiology information system yielded 865,879 imaging examinations and 4,508,030 patients. Although patient and imaging volume grew annually over the study period (by 6.8{\%} and 4.9{\%}, respectively), CT utilization as a percentage of total imaging decreased, compensated for by an increase in ultrasound use. This was most marked in the youngest age group. MR use as a percentage of total imaging was unchanged. The median volumetric CT dose index for each study protocol was reduced or stabilized. Conclusions The campaign resulted in a reduction in CT utilization, a reduction in radiation dose per study, and a compensatory rise in ultrasound use. An interactive aggressive educational campaign directed toward referring providers combined with protocol dose reduction efforts can be successful in reducing patient exposure from medical radiation.",
keywords = "computed tomography, dose, Image Gently, Image Wisely, Medical radiation",
author = "Kevin Fernandes and Levin, {Terry L.} and Miller, {Todd S.} and Schoenfeld, {Alan H.} and Amis, {E. Stephen}",
year = "2016",
month = "8",
day = "1",
doi = "10.1016/j.jacr.2016.04.025",
language = "English (US)",
volume = "13",
pages = "1010--1017",
journal = "Journal of the American College of Radiology",
issn = "1558-349X",
publisher = "Elsevier BV",
number = "8",

}

TY - JOUR

T1 - Evaluating an Image Gently and Image Wisely Campaign in a Multihospital Health Care System

AU - Fernandes, Kevin

AU - Levin, Terry L.

AU - Miller, Todd S.

AU - Schoenfeld, Alan H.

AU - Amis, E. Stephen

PY - 2016/8/1

Y1 - 2016/8/1

N2 - Purpose The efficacy of an Image Gently®/Image Wisely® radiology departmental campaign consisting of the optimization of CT protocols to reduce dose while maintaining quality, and an educational effort to alter the ordering patterns of referring physicians at a multihospital academic center, was evaluated. Methods The numbers of CT, MR, and ultrasound studies performed at inpatient, outpatient, and emergency facilities in the hospital system before and after the initiation of the departmental campaign (2010) were obtained for a 10-year period (2004-2014) using a radiology information system. For the same time period, dose per scan (volumetric CT dose index) was obtained through the Dose Index Registry®/National Radiology Data Registry for frequently performed studies. Descriptive statistics were used to analyze temporal trends in radiation dose and utilization across differing age groups: <20, 20 to 39, and 40 to 59 years. Results The radiology information system yielded 865,879 imaging examinations and 4,508,030 patients. Although patient and imaging volume grew annually over the study period (by 6.8% and 4.9%, respectively), CT utilization as a percentage of total imaging decreased, compensated for by an increase in ultrasound use. This was most marked in the youngest age group. MR use as a percentage of total imaging was unchanged. The median volumetric CT dose index for each study protocol was reduced or stabilized. Conclusions The campaign resulted in a reduction in CT utilization, a reduction in radiation dose per study, and a compensatory rise in ultrasound use. An interactive aggressive educational campaign directed toward referring providers combined with protocol dose reduction efforts can be successful in reducing patient exposure from medical radiation.

AB - Purpose The efficacy of an Image Gently®/Image Wisely® radiology departmental campaign consisting of the optimization of CT protocols to reduce dose while maintaining quality, and an educational effort to alter the ordering patterns of referring physicians at a multihospital academic center, was evaluated. Methods The numbers of CT, MR, and ultrasound studies performed at inpatient, outpatient, and emergency facilities in the hospital system before and after the initiation of the departmental campaign (2010) were obtained for a 10-year period (2004-2014) using a radiology information system. For the same time period, dose per scan (volumetric CT dose index) was obtained through the Dose Index Registry®/National Radiology Data Registry for frequently performed studies. Descriptive statistics were used to analyze temporal trends in radiation dose and utilization across differing age groups: <20, 20 to 39, and 40 to 59 years. Results The radiology information system yielded 865,879 imaging examinations and 4,508,030 patients. Although patient and imaging volume grew annually over the study period (by 6.8% and 4.9%, respectively), CT utilization as a percentage of total imaging decreased, compensated for by an increase in ultrasound use. This was most marked in the youngest age group. MR use as a percentage of total imaging was unchanged. The median volumetric CT dose index for each study protocol was reduced or stabilized. Conclusions The campaign resulted in a reduction in CT utilization, a reduction in radiation dose per study, and a compensatory rise in ultrasound use. An interactive aggressive educational campaign directed toward referring providers combined with protocol dose reduction efforts can be successful in reducing patient exposure from medical radiation.

KW - computed tomography

KW - dose

KW - Image Gently

KW - Image Wisely

KW - Medical radiation

UR - http://www.scopus.com/inward/record.url?scp=84991649556&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84991649556&partnerID=8YFLogxK

U2 - 10.1016/j.jacr.2016.04.025

DO - 10.1016/j.jacr.2016.04.025

M3 - Article

C2 - 27318579

AN - SCOPUS:84991649556

VL - 13

SP - 1010

EP - 1017

JO - Journal of the American College of Radiology

JF - Journal of the American College of Radiology

SN - 1558-349X

IS - 8

ER -