Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records

David L. Reich, Richard K. Wood, Raafat Mattar, Marina Krol, David C. Adams, Sabera Hossain, Carol A. Bodian

Research output: Contribution to journalArticle

105 Citations (Scopus)

Abstract

Previous publications suggest that handwritten anesthesia records are less accurate when compared with computer-generated records, but these studies were limited by small sample size, unblinded study design, and unpaired statistical comparisons. Eighty-one pairs of handwritten and computer-generated neurosurgical anesthesia records were retrospectively compared by using a matched sample design. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and heart rate (HR) data for each 5-min interval were transcribed from handwritten records. In computerized records, the median of up to 20 values was calculated for SAP, DAP, and HR for each consecutive 5-min epoch. The peak, trough, standard deviation, median, and absolute value of the fractional rate of change between adjacent 5-min epochs were calculated for each case. Pairwise comparisons were performed by using Wilcoxon tests. For SAP, DAP, and HR, the handwritten record peak, standard deviation, and fractional rate of change were less than, and the trough and median were larger than, those in corresponding computer records (all with P < 0.05, except DAP median and HR peak). Considering together all the recorded measurements from all cases, extreme values were recorded more frequently in computerized records than in the handwritten records.

Original languageEnglish (US)
Pages (from-to)612-616
Number of pages5
JournalAnesthesia and Analgesia
Volume91
Issue number3
DOIs
StatePublished - Jan 1 2000
Externally publishedYes

Fingerprint

Arterial Pressure
Anesthesia
Heart Rate
Blood Pressure
Sample Size

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records. / Reich, David L.; Wood, Richard K.; Mattar, Raafat; Krol, Marina; Adams, David C.; Hossain, Sabera; Bodian, Carol A.

In: Anesthesia and Analgesia, Vol. 91, No. 3, 01.01.2000, p. 612-616.

Research output: Contribution to journalArticle

Reich, David L. ; Wood, Richard K. ; Mattar, Raafat ; Krol, Marina ; Adams, David C. ; Hossain, Sabera ; Bodian, Carol A. / Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records. In: Anesthesia and Analgesia. 2000 ; Vol. 91, No. 3. pp. 612-616.
@article{85efe5efdd77412e9aafaf6d164e68a7,
title = "Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records",
abstract = "Previous publications suggest that handwritten anesthesia records are less accurate when compared with computer-generated records, but these studies were limited by small sample size, unblinded study design, and unpaired statistical comparisons. Eighty-one pairs of handwritten and computer-generated neurosurgical anesthesia records were retrospectively compared by using a matched sample design. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and heart rate (HR) data for each 5-min interval were transcribed from handwritten records. In computerized records, the median of up to 20 values was calculated for SAP, DAP, and HR for each consecutive 5-min epoch. The peak, trough, standard deviation, median, and absolute value of the fractional rate of change between adjacent 5-min epochs were calculated for each case. Pairwise comparisons were performed by using Wilcoxon tests. For SAP, DAP, and HR, the handwritten record peak, standard deviation, and fractional rate of change were less than, and the trough and median were larger than, those in corresponding computer records (all with P < 0.05, except DAP median and HR peak). Considering together all the recorded measurements from all cases, extreme values were recorded more frequently in computerized records than in the handwritten records.",
author = "Reich, {David L.} and Wood, {Richard K.} and Raafat Mattar and Marina Krol and Adams, {David C.} and Sabera Hossain and Bodian, {Carol A.}",
year = "2000",
month = "1",
day = "1",
doi = "10.1213/00000539-200009000-00022",
language = "English (US)",
volume = "91",
pages = "612--616",
journal = "Anesthesia and Analgesia",
issn = "0003-2999",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - Arterial blood pressure and heart rate discrepancies between handwritten and computerized anesthesia records

AU - Reich, David L.

AU - Wood, Richard K.

AU - Mattar, Raafat

AU - Krol, Marina

AU - Adams, David C.

AU - Hossain, Sabera

AU - Bodian, Carol A.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - Previous publications suggest that handwritten anesthesia records are less accurate when compared with computer-generated records, but these studies were limited by small sample size, unblinded study design, and unpaired statistical comparisons. Eighty-one pairs of handwritten and computer-generated neurosurgical anesthesia records were retrospectively compared by using a matched sample design. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and heart rate (HR) data for each 5-min interval were transcribed from handwritten records. In computerized records, the median of up to 20 values was calculated for SAP, DAP, and HR for each consecutive 5-min epoch. The peak, trough, standard deviation, median, and absolute value of the fractional rate of change between adjacent 5-min epochs were calculated for each case. Pairwise comparisons were performed by using Wilcoxon tests. For SAP, DAP, and HR, the handwritten record peak, standard deviation, and fractional rate of change were less than, and the trough and median were larger than, those in corresponding computer records (all with P < 0.05, except DAP median and HR peak). Considering together all the recorded measurements from all cases, extreme values were recorded more frequently in computerized records than in the handwritten records.

AB - Previous publications suggest that handwritten anesthesia records are less accurate when compared with computer-generated records, but these studies were limited by small sample size, unblinded study design, and unpaired statistical comparisons. Eighty-one pairs of handwritten and computer-generated neurosurgical anesthesia records were retrospectively compared by using a matched sample design. Systolic arterial pressure (SAP), diastolic arterial pressure (DAP), and heart rate (HR) data for each 5-min interval were transcribed from handwritten records. In computerized records, the median of up to 20 values was calculated for SAP, DAP, and HR for each consecutive 5-min epoch. The peak, trough, standard deviation, median, and absolute value of the fractional rate of change between adjacent 5-min epochs were calculated for each case. Pairwise comparisons were performed by using Wilcoxon tests. For SAP, DAP, and HR, the handwritten record peak, standard deviation, and fractional rate of change were less than, and the trough and median were larger than, those in corresponding computer records (all with P < 0.05, except DAP median and HR peak). Considering together all the recorded measurements from all cases, extreme values were recorded more frequently in computerized records than in the handwritten records.

UR - http://www.scopus.com/inward/record.url?scp=0033850045&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033850045&partnerID=8YFLogxK

U2 - 10.1213/00000539-200009000-00022

DO - 10.1213/00000539-200009000-00022

M3 - Article

C2 - 10960387

AN - SCOPUS:0033850045

VL - 91

SP - 612

EP - 616

JO - Anesthesia and Analgesia

JF - Anesthesia and Analgesia

SN - 0003-2999

IS - 3

ER -