Abstract

A clinical comparison, of two methods of afterload assessment, has been made. The first method, systemic vascular resistance index (SVRi), is based upon the traditional formula for afterload which utilizes central venous pressure (CVP), as well as cardiac index (Ci), and mean arterial blood pressure (MAP). The second method, total systemic vascular resistance index (TSVRi), also uses MAP and Ci. However, TSVRi ignores the contribution of CVP. This preliminary examination, of 10 randomlyselected ICU patients, has shown a high degree of correlation (ranging from 90 to 100%) between SVRi and TSVRi (P<0.0001). Furthermore, there was also a high degree of correlation (ranging from 94 to 100%) noted between the hour-to-hour change in SVRi with the hour-tohour change in TSVRi (P<0.0001). The results, of this pilot study, support the premise that the use of CVP may not always be necessary for afterload evaluation in the clinical setting. Minimally-invasive means of measuring both Ci and MAP, without CVP, may be adequate for use in assessing afterload.

Original languageEnglish (US)
Pages (from-to)246-252
Number of pages7
JournalCardiovascular Engineering
Volume10
Issue number4
DOIs
StatePublished - Dec 2010
Externally publishedYes

Keywords

  • Central venous pressure
  • Pulmonary artery occlusion catheter
  • Systemic vascular resistance index
  • Total systemic vascular resistance index

ASJC Scopus subject areas

  • Surgery
  • Cardiology and Cardiovascular Medicine
  • Transplantation

Fingerprint

Dive into the research topics of 'Afterload assessment with or without central venous pressure: A preliminary clinical comparison'. Together they form a unique fingerprint.

Cite this