TurboFLASH FAIR Imaging with Optimized Inversion and Imaging Profiles

Gaby S. Pell, David P. Lewis, Roger J. Ordidge, Craig A. Branch

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow-sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion: imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low-angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice-selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice-selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles.

Original languageEnglish (US)
Pages (from-to)46-54
Number of pages9
JournalMagnetic Resonance in Medicine
Volume51
Issue number1
DOIs
StatePublished - Jan 2004

Fingerprint

Animal Models

Keywords

  • Arterial spin labeling
  • FLASH
  • Perfusion
  • Quantification
  • RF pulses

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

TurboFLASH FAIR Imaging with Optimized Inversion and Imaging Profiles. / Pell, Gaby S.; Lewis, David P.; Ordidge, Roger J.; Branch, Craig A.

In: Magnetic Resonance in Medicine, Vol. 51, No. 1, 01.2004, p. 46-54.

Research output: Contribution to journalArticle

Pell, Gaby S. ; Lewis, David P. ; Ordidge, Roger J. ; Branch, Craig A. / TurboFLASH FAIR Imaging with Optimized Inversion and Imaging Profiles. In: Magnetic Resonance in Medicine. 2004 ; Vol. 51, No. 1. pp. 46-54.
@article{37fb0fb2b18e46bea82085c41cb08c9e,
title = "TurboFLASH FAIR Imaging with Optimized Inversion and Imaging Profiles",
abstract = "Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow-sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion: imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low-angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice-selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice-selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles.",
keywords = "Arterial spin labeling, FLASH, Perfusion, Quantification, RF pulses",
author = "Pell, {Gaby S.} and Lewis, {David P.} and Ordidge, {Roger J.} and Branch, {Craig A.}",
year = "2004",
month = "1",
doi = "10.1002/mrm.10674",
language = "English (US)",
volume = "51",
pages = "46--54",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - TurboFLASH FAIR Imaging with Optimized Inversion and Imaging Profiles

AU - Pell, Gaby S.

AU - Lewis, David P.

AU - Ordidge, Roger J.

AU - Branch, Craig A.

PY - 2004/1

Y1 - 2004/1

N2 - Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow-sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion: imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low-angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice-selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice-selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles.

AB - Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow-sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion: imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low-angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice-selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice-selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles.

KW - Arterial spin labeling

KW - FLASH

KW - Perfusion

KW - Quantification

KW - RF pulses

UR - http://www.scopus.com/inward/record.url?scp=0347634472&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0347634472&partnerID=8YFLogxK

U2 - 10.1002/mrm.10674

DO - 10.1002/mrm.10674

M3 - Article

VL - 51

SP - 46

EP - 54

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -