Transcatheter Closure of a Very Large Patent Ductus Arteriosus in a Pregnant Woman at 22 Weeks of Gestation

Joshua P. Kanter, William E. Hellenbrand, Robert H. Pass

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Successful transcatheter closure of a large PDA in a pregnant patient is reported using the Amplatzer ductal occluder device. This procedure was safe and uncomplicated, obviating the need for surgery in this high risk patient.

Original languageEnglish (US)
Pages (from-to)140-143
Number of pages4
JournalCatheterization and Cardiovascular Interventions
Volume61
Issue number1
DOIs
StatePublished - Jan 2004
Externally publishedYes

Fingerprint

Patent Ductus Arteriosus
Pregnant Women
Septal Occluder Device
Pregnancy

Keywords

  • Gestation
  • PDA
  • Transcatheter closure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Radiology Nuclear Medicine and imaging

Cite this

Transcatheter Closure of a Very Large Patent Ductus Arteriosus in a Pregnant Woman at 22 Weeks of Gestation. / Kanter, Joshua P.; Hellenbrand, William E.; Pass, Robert H.

In: Catheterization and Cardiovascular Interventions, Vol. 61, No. 1, 01.2004, p. 140-143.

Research output: Contribution to journalArticle

@article{a76d92f3339c42218b7b96321fcd6460,
title = "Transcatheter Closure of a Very Large Patent Ductus Arteriosus in a Pregnant Woman at 22 Weeks of Gestation",
abstract = "Successful transcatheter closure of a large PDA in a pregnant patient is reported using the Amplatzer ductal occluder device. This procedure was safe and uncomplicated, obviating the need for surgery in this high risk patient.",
keywords = "Gestation, PDA, Transcatheter closure",
author = "Kanter, {Joshua P.} and Hellenbrand, {William E.} and Pass, {Robert H.}",
year = "2004",
month = "1",
doi = "10.1002/ccd.10738",
language = "English (US)",
volume = "61",
pages = "140--143",
journal = "Catheterization and Cardiovascular Interventions",
issn = "1522-1946",
publisher = "Wiley-Liss Inc.",
number = "1",

}

TY - JOUR

T1 - Transcatheter Closure of a Very Large Patent Ductus Arteriosus in a Pregnant Woman at 22 Weeks of Gestation

AU - Kanter, Joshua P.

AU - Hellenbrand, William E.

AU - Pass, Robert H.

PY - 2004/1

Y1 - 2004/1

N2 - Successful transcatheter closure of a large PDA in a pregnant patient is reported using the Amplatzer ductal occluder device. This procedure was safe and uncomplicated, obviating the need for surgery in this high risk patient.

AB - Successful transcatheter closure of a large PDA in a pregnant patient is reported using the Amplatzer ductal occluder device. This procedure was safe and uncomplicated, obviating the need for surgery in this high risk patient.

KW - Gestation

KW - PDA

KW - Transcatheter closure

UR - http://www.scopus.com/inward/record.url?scp=0346101539&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0346101539&partnerID=8YFLogxK

U2 - 10.1002/ccd.10738

DO - 10.1002/ccd.10738

M3 - Article

VL - 61

SP - 140

EP - 143

JO - Catheterization and Cardiovascular Interventions

JF - Catheterization and Cardiovascular Interventions

SN - 1522-1946

IS - 1

ER -