The fetal Doppler mechanical PR interval: A validation study

Julie Glickstein, Jill Buyon, Mimi Kim, Deborah Friedman, Alfred Abuhamad, D. Ware Branch, Amy Sullivan, Mitchell Cohen, Joshua Copel, Mary Donofrio, Maurice Druzin, Thomas Wigton, Clifford Chin, Anne Dubin, David Rosenthal, George Van Hare, John Fernandes, Michelle Frommelt, Randall Kuhlmann, Colin PoonMonika Rutkowski, Eric Spooner

Research output: Contribution to journalArticlepeer-review

52 Scopus citations

Abstract

Objective: To evaluate the accuracy of pulsed Doppler-derived fetal PR interval measurements obtained by physicians participating in a multicenter prospective fetal echocardiographic study. Methods: Echocardiograms on healthy fetuses were performed and evaluated by 15 pediatric cardiologists/ perinatologists across the United States who are participating in a larger clinical trial involving fetuses at risk for autoantibody-associated congenital heart block. Prior to enrolling women in the main trial, each physician was provided with a teaching tape to demonstrate how the pulsed Doppler-derived PR interval is measured. The procedure involves placing a gated pulsed Doppler sample volume in the left ventricle at the junction of the anterior leaflet of the mitral valve and the left ventricular outflow tract in an apical 5-chamber view, and simultaneously obtaining left ventricular filling and emptying. Time intervals are measured from the onset of the mitral A wave (atrial systole) to the onset of the aortic pulsed Doppler tracing (ventricular systole). This represents the mechanical PR interval. Each physician measured the pulsed Doppler-derived fetal PR interval on 5 different subjects recruited from the physician's specific site. To validate each physician's technique, the tapes were sent to a central facility and the same intervals were remeasured by an experienced central reader (D.M.F.). A physician was determined to have adequate ability to measure the fetal PR interval if all 5 measurements were within ± 30 ms of the central reader's measurements, where 30 ms corresponds to 25% of the mean observed in normative PR interval data. This difference was deemed to be the minimum clinically important difference in Doppler PR interval. Results: Fourteen of the 15 physicians were considered to have adequate ability to measure the fetal PR interval according to our established criterion. The overall mean difference between the physicians and the central reader's measurements was -0.26 ± 11.04 ms (p = 0.84). In addition, 95% of the observed differences were included in the interval (-22.23 to 21.81), which is well within our clinically acceptable range of ± 30 ms. Conclusions: The pulsed Doppler assessment of the mechanical PR interval in the fetus can be accurately performed after minimal training. This technique may be a valuable tool for identification of early and potentially reversible conduction abnormalities in fetuses at risk for more advanced and permanent forms of heart block associated with maternal antibodies to SSA/Ro-SSB/La.

Original languageEnglish (US)
Pages (from-to)31-34
Number of pages4
JournalFetal Diagnosis and Therapy
Volume19
Issue number1
DOIs
StatePublished - 2004
Externally publishedYes

Keywords

  • Fetal PR interval
  • Fetal heart rate/rhythm
  • Validation study

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Embryology
  • Radiology Nuclear Medicine and imaging
  • Obstetrics and Gynecology

Fingerprint

Dive into the research topics of 'The fetal Doppler mechanical PR interval: A validation study'. Together they form a unique fingerprint.

Cite this