The effect of head tilt on keratometric measurement using the IOLMaster

C. Y. Park, J. R. Do, S. H. Kim, C. Y. Lim, Roy S. Chuck

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

Purpose: To investigate the effect of head tilt on keratometric measurement using the IOLMaster. Methods: Twenty-seven right eyes of 27 volunteers were examined using a manual keratometer (MK), automated keratometer (AK), and an IOLMaster. MK and AK measurements were performed in the upright head position, whereas IOLMaster measurements were performed in five different head positions (upright, 5° or 15° clockwise head tilt, and 5° or 15° counter-clockwise head tilt). The repeatability of IOLMaster was compared with MK and AK. The keratometric measurements (mean keratometric power, magnitude of astigmatism, and steep meridian) in different head positions were compared. Results: The IOLMaster showed good repeatability of keratometric measurement comparable to MK or AK. 15° and 5° clockwise head tilt resulted in 12.09±9.51 (mean±SD) (P<0.001 vs upright) and 5.51±5.97 (mean±SD) degrees (P<0.001) of clockwise rotation of steep meridian, respectively. 15° and 5° counter-clockwise head tilt resulted in 12.49±7.07 (mean±SD) (P<0.001) and 6.08±5.09 (mean±SD) degrees (P<0.001) of counter-clockwise rotation of steep meridian, respectively. Conclusion: sThe patient's head tilt (5° or 15°, clockwise or counter-clockwise) significantly changed the steep meridian of astigmatism measured using IOLMaster and the steep meridian generally shifted to the direction of head tilt. The importance of maintaining the upright head posture during IOLMaster measurement is demonstrated.

Original languageEnglish (US)
Pages (from-to)1411-1417
Number of pages7
JournalEye (Basingstoke)
Volume27
Issue number12
DOIs
StatePublished - Dec 2013

Fingerprint

Head
Meridians
Astigmatism
Posture
Volunteers

Keywords

  • Astigmatism
  • Cyclotorsion
  • Head tilt
  • IOLMaster
  • Keratometry

ASJC Scopus subject areas

  • Ophthalmology

Cite this

The effect of head tilt on keratometric measurement using the IOLMaster. / Park, C. Y.; Do, J. R.; Kim, S. H.; Lim, C. Y.; Chuck, Roy S.

In: Eye (Basingstoke), Vol. 27, No. 12, 12.2013, p. 1411-1417.

Research output: Contribution to journalArticle

Park, C. Y. ; Do, J. R. ; Kim, S. H. ; Lim, C. Y. ; Chuck, Roy S. / The effect of head tilt on keratometric measurement using the IOLMaster. In: Eye (Basingstoke). 2013 ; Vol. 27, No. 12. pp. 1411-1417.
@article{aa6b64841ee04316bf2baaed30065bb5,
title = "The effect of head tilt on keratometric measurement using the IOLMaster",
abstract = "Purpose: To investigate the effect of head tilt on keratometric measurement using the IOLMaster. Methods: Twenty-seven right eyes of 27 volunteers were examined using a manual keratometer (MK), automated keratometer (AK), and an IOLMaster. MK and AK measurements were performed in the upright head position, whereas IOLMaster measurements were performed in five different head positions (upright, 5° or 15° clockwise head tilt, and 5° or 15° counter-clockwise head tilt). The repeatability of IOLMaster was compared with MK and AK. The keratometric measurements (mean keratometric power, magnitude of astigmatism, and steep meridian) in different head positions were compared. Results: The IOLMaster showed good repeatability of keratometric measurement comparable to MK or AK. 15° and 5° clockwise head tilt resulted in 12.09±9.51 (mean±SD) (P<0.001 vs upright) and 5.51±5.97 (mean±SD) degrees (P<0.001) of clockwise rotation of steep meridian, respectively. 15° and 5° counter-clockwise head tilt resulted in 12.49±7.07 (mean±SD) (P<0.001) and 6.08±5.09 (mean±SD) degrees (P<0.001) of counter-clockwise rotation of steep meridian, respectively. Conclusion: sThe patient's head tilt (5° or 15°, clockwise or counter-clockwise) significantly changed the steep meridian of astigmatism measured using IOLMaster and the steep meridian generally shifted to the direction of head tilt. The importance of maintaining the upright head posture during IOLMaster measurement is demonstrated.",
keywords = "Astigmatism, Cyclotorsion, Head tilt, IOLMaster, Keratometry",
author = "Park, {C. Y.} and Do, {J. R.} and Kim, {S. H.} and Lim, {C. Y.} and Chuck, {Roy S.}",
year = "2013",
month = "12",
doi = "10.1038/eye.2013.209",
language = "English (US)",
volume = "27",
pages = "1411--1417",
journal = "Eye (Basingstoke)",
issn = "0950-222X",
publisher = "Nature Publishing Group",
number = "12",

}

TY - JOUR

T1 - The effect of head tilt on keratometric measurement using the IOLMaster

AU - Park, C. Y.

AU - Do, J. R.

AU - Kim, S. H.

AU - Lim, C. Y.

AU - Chuck, Roy S.

PY - 2013/12

Y1 - 2013/12

N2 - Purpose: To investigate the effect of head tilt on keratometric measurement using the IOLMaster. Methods: Twenty-seven right eyes of 27 volunteers were examined using a manual keratometer (MK), automated keratometer (AK), and an IOLMaster. MK and AK measurements were performed in the upright head position, whereas IOLMaster measurements were performed in five different head positions (upright, 5° or 15° clockwise head tilt, and 5° or 15° counter-clockwise head tilt). The repeatability of IOLMaster was compared with MK and AK. The keratometric measurements (mean keratometric power, magnitude of astigmatism, and steep meridian) in different head positions were compared. Results: The IOLMaster showed good repeatability of keratometric measurement comparable to MK or AK. 15° and 5° clockwise head tilt resulted in 12.09±9.51 (mean±SD) (P<0.001 vs upright) and 5.51±5.97 (mean±SD) degrees (P<0.001) of clockwise rotation of steep meridian, respectively. 15° and 5° counter-clockwise head tilt resulted in 12.49±7.07 (mean±SD) (P<0.001) and 6.08±5.09 (mean±SD) degrees (P<0.001) of counter-clockwise rotation of steep meridian, respectively. Conclusion: sThe patient's head tilt (5° or 15°, clockwise or counter-clockwise) significantly changed the steep meridian of astigmatism measured using IOLMaster and the steep meridian generally shifted to the direction of head tilt. The importance of maintaining the upright head posture during IOLMaster measurement is demonstrated.

AB - Purpose: To investigate the effect of head tilt on keratometric measurement using the IOLMaster. Methods: Twenty-seven right eyes of 27 volunteers were examined using a manual keratometer (MK), automated keratometer (AK), and an IOLMaster. MK and AK measurements were performed in the upright head position, whereas IOLMaster measurements were performed in five different head positions (upright, 5° or 15° clockwise head tilt, and 5° or 15° counter-clockwise head tilt). The repeatability of IOLMaster was compared with MK and AK. The keratometric measurements (mean keratometric power, magnitude of astigmatism, and steep meridian) in different head positions were compared. Results: The IOLMaster showed good repeatability of keratometric measurement comparable to MK or AK. 15° and 5° clockwise head tilt resulted in 12.09±9.51 (mean±SD) (P<0.001 vs upright) and 5.51±5.97 (mean±SD) degrees (P<0.001) of clockwise rotation of steep meridian, respectively. 15° and 5° counter-clockwise head tilt resulted in 12.49±7.07 (mean±SD) (P<0.001) and 6.08±5.09 (mean±SD) degrees (P<0.001) of counter-clockwise rotation of steep meridian, respectively. Conclusion: sThe patient's head tilt (5° or 15°, clockwise or counter-clockwise) significantly changed the steep meridian of astigmatism measured using IOLMaster and the steep meridian generally shifted to the direction of head tilt. The importance of maintaining the upright head posture during IOLMaster measurement is demonstrated.

KW - Astigmatism

KW - Cyclotorsion

KW - Head tilt

KW - IOLMaster

KW - Keratometry

UR - http://www.scopus.com/inward/record.url?scp=84890498609&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890498609&partnerID=8YFLogxK

U2 - 10.1038/eye.2013.209

DO - 10.1038/eye.2013.209

M3 - Article

VL - 27

SP - 1411

EP - 1417

JO - Eye (Basingstoke)

JF - Eye (Basingstoke)

SN - 0950-222X

IS - 12

ER -