SU‐FF‐T‐412

The Feasibility of Using Tomotherapy Hi‐Art Machine for Stereotactic Radiosurgery

H. Jaradat, Wolfgang A. Tome, M. Mehta

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Purpose: To study the feasibility of treating multiple‐brain metastass with stereotactic radiosurgery using the tomotherapy Hi‐Art machine, and to compare tomotherapy stereotactic radiosurgery treatment plans with conventional linac‐based stereotactic radiosurgery plans. Method and Materials: Five previously treated patients with multiple brain metastases ranging from 1 to 5 metastases were selected for the study. These five patients were treated with linac stereotactic radiosurgery. The same structures and prescription doses used for linac radiosurgery were also used to produce stereotactic radiosurgery treatment plans on the tomotherapy planning system. In order to compare the tomotherapy plans to the linac‐based plans, the homogeneity of the target volumes, as well as the PITV, the volume of normal brain tissue receiving at least 10Gy and treatment time were considered. Results: Analysis of the five plans shows that the target dose uniformity, target dose conformality, and the treatment time for each plan is much improved for tomotherapy. The plans show that on average using tomotherapy planning system increases the dose uniformity by 70%, increases the target‐dose conformality by 42% while it reduces the normal tissue volume receiving at least 10 Gy by about 40% for large metastases. On the other hand, for metastases smaller than 1cc tomotherapy increases the 10.0 Gy volume over that for a conventional linac plan by about 60%. Conclusion: These results show that tomotherapy could be used for treating patients with multiple brain metastases using stereotactic radiosurgey.

Original languageEnglish (US)
Pages (from-to)2045-2046
Number of pages2
JournalMedical Physics
Volume32
Issue number6
DOIs
StatePublished - 2005
Externally publishedYes

Fingerprint

Radiosurgery
Neoplasm Metastasis
Brain
Feasibility Studies
Therapeutics
Prescriptions

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

SU‐FF‐T‐412 : The Feasibility of Using Tomotherapy Hi‐Art Machine for Stereotactic Radiosurgery. / Jaradat, H.; Tome, Wolfgang A.; Mehta, M.

In: Medical Physics, Vol. 32, No. 6, 2005, p. 2045-2046.

Research output: Contribution to journalArticle

@article{36781b180d904ae98c77748e0a7cd7f7,
title = "SU‐FF‐T‐412: The Feasibility of Using Tomotherapy Hi‐Art Machine for Stereotactic Radiosurgery",
abstract = "Purpose: To study the feasibility of treating multiple‐brain metastass with stereotactic radiosurgery using the tomotherapy Hi‐Art machine, and to compare tomotherapy stereotactic radiosurgery treatment plans with conventional linac‐based stereotactic radiosurgery plans. Method and Materials: Five previously treated patients with multiple brain metastases ranging from 1 to 5 metastases were selected for the study. These five patients were treated with linac stereotactic radiosurgery. The same structures and prescription doses used for linac radiosurgery were also used to produce stereotactic radiosurgery treatment plans on the tomotherapy planning system. In order to compare the tomotherapy plans to the linac‐based plans, the homogeneity of the target volumes, as well as the PITV, the volume of normal brain tissue receiving at least 10Gy and treatment time were considered. Results: Analysis of the five plans shows that the target dose uniformity, target dose conformality, and the treatment time for each plan is much improved for tomotherapy. The plans show that on average using tomotherapy planning system increases the dose uniformity by 70{\%}, increases the target‐dose conformality by 42{\%} while it reduces the normal tissue volume receiving at least 10 Gy by about 40{\%} for large metastases. On the other hand, for metastases smaller than 1cc tomotherapy increases the 10.0 Gy volume over that for a conventional linac plan by about 60{\%}. Conclusion: These results show that tomotherapy could be used for treating patients with multiple brain metastases using stereotactic radiosurgey.",
author = "H. Jaradat and Tome, {Wolfgang A.} and M. Mehta",
year = "2005",
doi = "10.1118/1.1998211",
language = "English (US)",
volume = "32",
pages = "2045--2046",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - SU‐FF‐T‐412

T2 - The Feasibility of Using Tomotherapy Hi‐Art Machine for Stereotactic Radiosurgery

AU - Jaradat, H.

AU - Tome, Wolfgang A.

AU - Mehta, M.

PY - 2005

Y1 - 2005

N2 - Purpose: To study the feasibility of treating multiple‐brain metastass with stereotactic radiosurgery using the tomotherapy Hi‐Art machine, and to compare tomotherapy stereotactic radiosurgery treatment plans with conventional linac‐based stereotactic radiosurgery plans. Method and Materials: Five previously treated patients with multiple brain metastases ranging from 1 to 5 metastases were selected for the study. These five patients were treated with linac stereotactic radiosurgery. The same structures and prescription doses used for linac radiosurgery were also used to produce stereotactic radiosurgery treatment plans on the tomotherapy planning system. In order to compare the tomotherapy plans to the linac‐based plans, the homogeneity of the target volumes, as well as the PITV, the volume of normal brain tissue receiving at least 10Gy and treatment time were considered. Results: Analysis of the five plans shows that the target dose uniformity, target dose conformality, and the treatment time for each plan is much improved for tomotherapy. The plans show that on average using tomotherapy planning system increases the dose uniformity by 70%, increases the target‐dose conformality by 42% while it reduces the normal tissue volume receiving at least 10 Gy by about 40% for large metastases. On the other hand, for metastases smaller than 1cc tomotherapy increases the 10.0 Gy volume over that for a conventional linac plan by about 60%. Conclusion: These results show that tomotherapy could be used for treating patients with multiple brain metastases using stereotactic radiosurgey.

AB - Purpose: To study the feasibility of treating multiple‐brain metastass with stereotactic radiosurgery using the tomotherapy Hi‐Art machine, and to compare tomotherapy stereotactic radiosurgery treatment plans with conventional linac‐based stereotactic radiosurgery plans. Method and Materials: Five previously treated patients with multiple brain metastases ranging from 1 to 5 metastases were selected for the study. These five patients were treated with linac stereotactic radiosurgery. The same structures and prescription doses used for linac radiosurgery were also used to produce stereotactic radiosurgery treatment plans on the tomotherapy planning system. In order to compare the tomotherapy plans to the linac‐based plans, the homogeneity of the target volumes, as well as the PITV, the volume of normal brain tissue receiving at least 10Gy and treatment time were considered. Results: Analysis of the five plans shows that the target dose uniformity, target dose conformality, and the treatment time for each plan is much improved for tomotherapy. The plans show that on average using tomotherapy planning system increases the dose uniformity by 70%, increases the target‐dose conformality by 42% while it reduces the normal tissue volume receiving at least 10 Gy by about 40% for large metastases. On the other hand, for metastases smaller than 1cc tomotherapy increases the 10.0 Gy volume over that for a conventional linac plan by about 60%. Conclusion: These results show that tomotherapy could be used for treating patients with multiple brain metastases using stereotactic radiosurgey.

UR - http://www.scopus.com/inward/record.url?scp=60849129579&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=60849129579&partnerID=8YFLogxK

U2 - 10.1118/1.1998211

DO - 10.1118/1.1998211

M3 - Article

VL - 32

SP - 2045

EP - 2046

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -