Safety and effectiveness of transvenous lead extraction in octogenarians

Gemma Pelargonio, Maria L. Narducci, Eleonora Russo, Michela Casella, Pasquale Santangeli, Robert Canby, Amin Al-Ahmad, Larry D. Price, Luigi Di Biase, Candice J. Kwark, Mark Harwood, Francesco Perna, Gianluigi Bencardino, Carolina Ierardi, Enrico M. Trecarichi, Enrica Santelli, Mario Tumbarello, Prasant Mohanty, Shane Bailey, John David BurkhardtFulvio Bellocci, Andrea Natale, Antonio Dello Russo

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Transvenous Lead Extraction. Introduction: As the population ages, the number of elderly patients with implantable cardiac devices referred for transvenous lead extraction will dramatically increase in Western countries. The safety and effectiveness of lead extraction in elderly patients has not been well evaluated. We report the safety and effectiveness of transvenous lead extraction in octogenarians. Methods and Results: From January 2005 to January 2011, we reviewed data from consecutive patients ≥ 80 years referred to our institutions for transvenous lead extraction because of cardiac device infection or lead malfunction. Clinical characteristics, procedural features, and periprocedural major and minor complications were compared between octogenarians and younger patients. Out of 849 patients undergoing lead extraction in the participating institutions during the study period, 150 (18%) patients were octogenarians (mean age 84 years; range 80-96; 64% males). A significantly higher percentage of octogenarians presented with chronic renal failure (55% vs 26%; P < 0.001), history of malignancy (22% vs 6%; P < 0.001), and chronic obstructive pulmonary disease (46% vs 19%; P < 0.001). Complete lead extraction rates were similar in the 2 age groups (97% in octogenarians vs 96% in patients <80 years; P = 0.39). Periprocedural death occurred in 2 (1.3%) patients ≥80 years and in 5 (0.72%) patients <80 years (P = 0.45 for comparison). No differences in terms of other periprocedural major and minor complications were found between the 2 age groups. Conclusion: Despite presenting with a significantly higher rate of comorbidities, transvenous lead extraction can be performed safely and successfully in octogenarians.

Original languageEnglish (US)
Pages (from-to)1103-1108
Number of pages6
JournalJournal of Cardiovascular Electrophysiology
Volume23
Issue number10
DOIs
StatePublished - Oct 2012
Externally publishedYes

Fingerprint

Safety
Age Groups
Lead
Equipment and Supplies
Chronic Obstructive Pulmonary Disease
Chronic Kidney Failure
Comorbidity
Infection
Population
Neoplasms

Keywords

  • elderly
  • implantable cardioverter defibrillator
  • infection
  • lead extraction
  • octogenarians
  • pacemaker

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Pelargonio, G., Narducci, M. L., Russo, E., Casella, M., Santangeli, P., Canby, R., ... Russo, A. D. (2012). Safety and effectiveness of transvenous lead extraction in octogenarians. Journal of Cardiovascular Electrophysiology, 23(10), 1103-1108. https://doi.org/10.1111/j.1540-8167.2012.02372.x

Safety and effectiveness of transvenous lead extraction in octogenarians. / Pelargonio, Gemma; Narducci, Maria L.; Russo, Eleonora; Casella, Michela; Santangeli, Pasquale; Canby, Robert; Al-Ahmad, Amin; Price, Larry D.; Di Biase, Luigi; Kwark, Candice J.; Harwood, Mark; Perna, Francesco; Bencardino, Gianluigi; Ierardi, Carolina; Trecarichi, Enrico M.; Santelli, Enrica; Tumbarello, Mario; Mohanty, Prasant; Bailey, Shane; Burkhardt, John David; Bellocci, Fulvio; Natale, Andrea; Russo, Antonio Dello.

In: Journal of Cardiovascular Electrophysiology, Vol. 23, No. 10, 10.2012, p. 1103-1108.

Research output: Contribution to journalArticle

Pelargonio, G, Narducci, ML, Russo, E, Casella, M, Santangeli, P, Canby, R, Al-Ahmad, A, Price, LD, Di Biase, L, Kwark, CJ, Harwood, M, Perna, F, Bencardino, G, Ierardi, C, Trecarichi, EM, Santelli, E, Tumbarello, M, Mohanty, P, Bailey, S, Burkhardt, JD, Bellocci, F, Natale, A & Russo, AD 2012, 'Safety and effectiveness of transvenous lead extraction in octogenarians', Journal of Cardiovascular Electrophysiology, vol. 23, no. 10, pp. 1103-1108. https://doi.org/10.1111/j.1540-8167.2012.02372.x
Pelargonio, Gemma ; Narducci, Maria L. ; Russo, Eleonora ; Casella, Michela ; Santangeli, Pasquale ; Canby, Robert ; Al-Ahmad, Amin ; Price, Larry D. ; Di Biase, Luigi ; Kwark, Candice J. ; Harwood, Mark ; Perna, Francesco ; Bencardino, Gianluigi ; Ierardi, Carolina ; Trecarichi, Enrico M. ; Santelli, Enrica ; Tumbarello, Mario ; Mohanty, Prasant ; Bailey, Shane ; Burkhardt, John David ; Bellocci, Fulvio ; Natale, Andrea ; Russo, Antonio Dello. / Safety and effectiveness of transvenous lead extraction in octogenarians. In: Journal of Cardiovascular Electrophysiology. 2012 ; Vol. 23, No. 10. pp. 1103-1108.
@article{e02567d4ccbf4093909f1ef7df542a29,
title = "Safety and effectiveness of transvenous lead extraction in octogenarians",
abstract = "Transvenous Lead Extraction. Introduction: As the population ages, the number of elderly patients with implantable cardiac devices referred for transvenous lead extraction will dramatically increase in Western countries. The safety and effectiveness of lead extraction in elderly patients has not been well evaluated. We report the safety and effectiveness of transvenous lead extraction in octogenarians. Methods and Results: From January 2005 to January 2011, we reviewed data from consecutive patients ≥ 80 years referred to our institutions for transvenous lead extraction because of cardiac device infection or lead malfunction. Clinical characteristics, procedural features, and periprocedural major and minor complications were compared between octogenarians and younger patients. Out of 849 patients undergoing lead extraction in the participating institutions during the study period, 150 (18{\%}) patients were octogenarians (mean age 84 years; range 80-96; 64{\%} males). A significantly higher percentage of octogenarians presented with chronic renal failure (55{\%} vs 26{\%}; P < 0.001), history of malignancy (22{\%} vs 6{\%}; P < 0.001), and chronic obstructive pulmonary disease (46{\%} vs 19{\%}; P < 0.001). Complete lead extraction rates were similar in the 2 age groups (97{\%} in octogenarians vs 96{\%} in patients <80 years; P = 0.39). Periprocedural death occurred in 2 (1.3{\%}) patients ≥80 years and in 5 (0.72{\%}) patients <80 years (P = 0.45 for comparison). No differences in terms of other periprocedural major and minor complications were found between the 2 age groups. Conclusion: Despite presenting with a significantly higher rate of comorbidities, transvenous lead extraction can be performed safely and successfully in octogenarians.",
keywords = "elderly, implantable cardioverter defibrillator, infection, lead extraction, octogenarians, pacemaker",
author = "Gemma Pelargonio and Narducci, {Maria L.} and Eleonora Russo and Michela Casella and Pasquale Santangeli and Robert Canby and Amin Al-Ahmad and Price, {Larry D.} and {Di Biase}, Luigi and Kwark, {Candice J.} and Mark Harwood and Francesco Perna and Gianluigi Bencardino and Carolina Ierardi and Trecarichi, {Enrico M.} and Enrica Santelli and Mario Tumbarello and Prasant Mohanty and Shane Bailey and Burkhardt, {John David} and Fulvio Bellocci and Andrea Natale and Russo, {Antonio Dello}",
year = "2012",
month = "10",
doi = "10.1111/j.1540-8167.2012.02372.x",
language = "English (US)",
volume = "23",
pages = "1103--1108",
journal = "Journal of Cardiovascular Electrophysiology",
issn = "1045-3873",
publisher = "Wiley-Blackwell",
number = "10",

}

TY - JOUR

T1 - Safety and effectiveness of transvenous lead extraction in octogenarians

AU - Pelargonio, Gemma

AU - Narducci, Maria L.

AU - Russo, Eleonora

AU - Casella, Michela

AU - Santangeli, Pasquale

AU - Canby, Robert

AU - Al-Ahmad, Amin

AU - Price, Larry D.

AU - Di Biase, Luigi

AU - Kwark, Candice J.

AU - Harwood, Mark

AU - Perna, Francesco

AU - Bencardino, Gianluigi

AU - Ierardi, Carolina

AU - Trecarichi, Enrico M.

AU - Santelli, Enrica

AU - Tumbarello, Mario

AU - Mohanty, Prasant

AU - Bailey, Shane

AU - Burkhardt, John David

AU - Bellocci, Fulvio

AU - Natale, Andrea

AU - Russo, Antonio Dello

PY - 2012/10

Y1 - 2012/10

N2 - Transvenous Lead Extraction. Introduction: As the population ages, the number of elderly patients with implantable cardiac devices referred for transvenous lead extraction will dramatically increase in Western countries. The safety and effectiveness of lead extraction in elderly patients has not been well evaluated. We report the safety and effectiveness of transvenous lead extraction in octogenarians. Methods and Results: From January 2005 to January 2011, we reviewed data from consecutive patients ≥ 80 years referred to our institutions for transvenous lead extraction because of cardiac device infection or lead malfunction. Clinical characteristics, procedural features, and periprocedural major and minor complications were compared between octogenarians and younger patients. Out of 849 patients undergoing lead extraction in the participating institutions during the study period, 150 (18%) patients were octogenarians (mean age 84 years; range 80-96; 64% males). A significantly higher percentage of octogenarians presented with chronic renal failure (55% vs 26%; P < 0.001), history of malignancy (22% vs 6%; P < 0.001), and chronic obstructive pulmonary disease (46% vs 19%; P < 0.001). Complete lead extraction rates were similar in the 2 age groups (97% in octogenarians vs 96% in patients <80 years; P = 0.39). Periprocedural death occurred in 2 (1.3%) patients ≥80 years and in 5 (0.72%) patients <80 years (P = 0.45 for comparison). No differences in terms of other periprocedural major and minor complications were found between the 2 age groups. Conclusion: Despite presenting with a significantly higher rate of comorbidities, transvenous lead extraction can be performed safely and successfully in octogenarians.

AB - Transvenous Lead Extraction. Introduction: As the population ages, the number of elderly patients with implantable cardiac devices referred for transvenous lead extraction will dramatically increase in Western countries. The safety and effectiveness of lead extraction in elderly patients has not been well evaluated. We report the safety and effectiveness of transvenous lead extraction in octogenarians. Methods and Results: From January 2005 to January 2011, we reviewed data from consecutive patients ≥ 80 years referred to our institutions for transvenous lead extraction because of cardiac device infection or lead malfunction. Clinical characteristics, procedural features, and periprocedural major and minor complications were compared between octogenarians and younger patients. Out of 849 patients undergoing lead extraction in the participating institutions during the study period, 150 (18%) patients were octogenarians (mean age 84 years; range 80-96; 64% males). A significantly higher percentage of octogenarians presented with chronic renal failure (55% vs 26%; P < 0.001), history of malignancy (22% vs 6%; P < 0.001), and chronic obstructive pulmonary disease (46% vs 19%; P < 0.001). Complete lead extraction rates were similar in the 2 age groups (97% in octogenarians vs 96% in patients <80 years; P = 0.39). Periprocedural death occurred in 2 (1.3%) patients ≥80 years and in 5 (0.72%) patients <80 years (P = 0.45 for comparison). No differences in terms of other periprocedural major and minor complications were found between the 2 age groups. Conclusion: Despite presenting with a significantly higher rate of comorbidities, transvenous lead extraction can be performed safely and successfully in octogenarians.

KW - elderly

KW - implantable cardioverter defibrillator

KW - infection

KW - lead extraction

KW - octogenarians

KW - pacemaker

UR - http://www.scopus.com/inward/record.url?scp=84867741186&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84867741186&partnerID=8YFLogxK

U2 - 10.1111/j.1540-8167.2012.02372.x

DO - 10.1111/j.1540-8167.2012.02372.x

M3 - Article

C2 - 22882701

AN - SCOPUS:84867741186

VL - 23

SP - 1103

EP - 1108

JO - Journal of Cardiovascular Electrophysiology

JF - Journal of Cardiovascular Electrophysiology

SN - 1045-3873

IS - 10

ER -