Relationship between the upper limit of vulnerability determined in normal sinus rhythm and the defibrillation threshold in patients with implantable cardioverter defibrillators

Richard C. Hui, Larry Rosenthal, Brian Ramza, Emmanuel Nsah, John Lawrence, Gordon F. Tomaselli, Ronald Berger, Hugh Calkins

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

The upper limit of vulnerability is the strength above which ventricular fibrillation is no longer inducible with a shock delivered during the vulnerable phase of the cardiac cycle. It has been demonstrated that the upper limit of vulnerability correlates with the defibrillation threshold in a paced rhythm. The purpose of this study is to evaluate the correlation of the upper limit of vulnerability determined in normal sinus rhythm with the defibrillation threshold using a simplified protocol in patients undergoing placement of an ICD. We studied 28 patients who underwent ICD implantation. CPI generators and Endotak leads were used in all patients. Device-based testing was used to determine the defibrillation threshold and the upper limit of vulnerability. The upper limit of vulnerability was tested with three shocks delivered at 0, 20, and 40 ms before the peak of the T wave during normal sinus rhythm. The defibrillation threshold was determined by a simple step up-down protocol. The upper limit of vulnerability (9.0 ± 4.5 J) did not significantly differ from the defibrillation threshold (9.9 ± 4.0 J), P = NS. A close correlation was present, correlation coefficient = 0.75, P < 0.0001. The upper limit of vulnerability was within 5 J of the defibrillation threshold in 27 (96%) of the 28 patients. The upper limit of vulnerability underestimated the defibrillation threshold by 10 J in one patient who had a defibrillation threshold of 15 J. The upper limit of vulnerability determined in normal sinus rhythm correlates significantly with the defibrillation threshold in patients undergoing ICD implantation. The protocol is simple and easily implemented clinically.

Original languageEnglish (US)
Pages (from-to)687-693
Number of pages7
JournalPACE - Pacing and Clinical Electrophysiology
Volume21
Issue number4 I
DOIs
StatePublished - Jan 1 1998
Externally publishedYes

Fingerprint

Implantable Defibrillators
Shock
Ventricular Fibrillation
Equipment and Supplies

Keywords

  • Defibrillation threshold
  • Implantable cardioverter defibrillator
  • Upper limit of vulnerability

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Relationship between the upper limit of vulnerability determined in normal sinus rhythm and the defibrillation threshold in patients with implantable cardioverter defibrillators. / Hui, Richard C.; Rosenthal, Larry; Ramza, Brian; Nsah, Emmanuel; Lawrence, John; Tomaselli, Gordon F.; Berger, Ronald; Calkins, Hugh.

In: PACE - Pacing and Clinical Electrophysiology, Vol. 21, No. 4 I, 01.01.1998, p. 687-693.

Research output: Contribution to journalArticle

Hui, Richard C. ; Rosenthal, Larry ; Ramza, Brian ; Nsah, Emmanuel ; Lawrence, John ; Tomaselli, Gordon F. ; Berger, Ronald ; Calkins, Hugh. / Relationship between the upper limit of vulnerability determined in normal sinus rhythm and the defibrillation threshold in patients with implantable cardioverter defibrillators. In: PACE - Pacing and Clinical Electrophysiology. 1998 ; Vol. 21, No. 4 I. pp. 687-693.
@article{c289121678a34609b29f09dfadbdc710,
title = "Relationship between the upper limit of vulnerability determined in normal sinus rhythm and the defibrillation threshold in patients with implantable cardioverter defibrillators",
abstract = "The upper limit of vulnerability is the strength above which ventricular fibrillation is no longer inducible with a shock delivered during the vulnerable phase of the cardiac cycle. It has been demonstrated that the upper limit of vulnerability correlates with the defibrillation threshold in a paced rhythm. The purpose of this study is to evaluate the correlation of the upper limit of vulnerability determined in normal sinus rhythm with the defibrillation threshold using a simplified protocol in patients undergoing placement of an ICD. We studied 28 patients who underwent ICD implantation. CPI generators and Endotak leads were used in all patients. Device-based testing was used to determine the defibrillation threshold and the upper limit of vulnerability. The upper limit of vulnerability was tested with three shocks delivered at 0, 20, and 40 ms before the peak of the T wave during normal sinus rhythm. The defibrillation threshold was determined by a simple step up-down protocol. The upper limit of vulnerability (9.0 ± 4.5 J) did not significantly differ from the defibrillation threshold (9.9 ± 4.0 J), P = NS. A close correlation was present, correlation coefficient = 0.75, P < 0.0001. The upper limit of vulnerability was within 5 J of the defibrillation threshold in 27 (96{\%}) of the 28 patients. The upper limit of vulnerability underestimated the defibrillation threshold by 10 J in one patient who had a defibrillation threshold of 15 J. The upper limit of vulnerability determined in normal sinus rhythm correlates significantly with the defibrillation threshold in patients undergoing ICD implantation. The protocol is simple and easily implemented clinically.",
keywords = "Defibrillation threshold, Implantable cardioverter defibrillator, Upper limit of vulnerability",
author = "Hui, {Richard C.} and Larry Rosenthal and Brian Ramza and Emmanuel Nsah and John Lawrence and Tomaselli, {Gordon F.} and Ronald Berger and Hugh Calkins",
year = "1998",
month = "1",
day = "1",
doi = "10.1111/j.1540-8159.1998.tb00124.x",
language = "English (US)",
volume = "21",
pages = "687--693",
journal = "PACE - Pacing and Clinical Electrophysiology",
issn = "0147-8389",
publisher = "Wiley-Blackwell",
number = "4 I",

}

TY - JOUR

T1 - Relationship between the upper limit of vulnerability determined in normal sinus rhythm and the defibrillation threshold in patients with implantable cardioverter defibrillators

AU - Hui, Richard C.

AU - Rosenthal, Larry

AU - Ramza, Brian

AU - Nsah, Emmanuel

AU - Lawrence, John

AU - Tomaselli, Gordon F.

AU - Berger, Ronald

AU - Calkins, Hugh

PY - 1998/1/1

Y1 - 1998/1/1

N2 - The upper limit of vulnerability is the strength above which ventricular fibrillation is no longer inducible with a shock delivered during the vulnerable phase of the cardiac cycle. It has been demonstrated that the upper limit of vulnerability correlates with the defibrillation threshold in a paced rhythm. The purpose of this study is to evaluate the correlation of the upper limit of vulnerability determined in normal sinus rhythm with the defibrillation threshold using a simplified protocol in patients undergoing placement of an ICD. We studied 28 patients who underwent ICD implantation. CPI generators and Endotak leads were used in all patients. Device-based testing was used to determine the defibrillation threshold and the upper limit of vulnerability. The upper limit of vulnerability was tested with three shocks delivered at 0, 20, and 40 ms before the peak of the T wave during normal sinus rhythm. The defibrillation threshold was determined by a simple step up-down protocol. The upper limit of vulnerability (9.0 ± 4.5 J) did not significantly differ from the defibrillation threshold (9.9 ± 4.0 J), P = NS. A close correlation was present, correlation coefficient = 0.75, P < 0.0001. The upper limit of vulnerability was within 5 J of the defibrillation threshold in 27 (96%) of the 28 patients. The upper limit of vulnerability underestimated the defibrillation threshold by 10 J in one patient who had a defibrillation threshold of 15 J. The upper limit of vulnerability determined in normal sinus rhythm correlates significantly with the defibrillation threshold in patients undergoing ICD implantation. The protocol is simple and easily implemented clinically.

AB - The upper limit of vulnerability is the strength above which ventricular fibrillation is no longer inducible with a shock delivered during the vulnerable phase of the cardiac cycle. It has been demonstrated that the upper limit of vulnerability correlates with the defibrillation threshold in a paced rhythm. The purpose of this study is to evaluate the correlation of the upper limit of vulnerability determined in normal sinus rhythm with the defibrillation threshold using a simplified protocol in patients undergoing placement of an ICD. We studied 28 patients who underwent ICD implantation. CPI generators and Endotak leads were used in all patients. Device-based testing was used to determine the defibrillation threshold and the upper limit of vulnerability. The upper limit of vulnerability was tested with three shocks delivered at 0, 20, and 40 ms before the peak of the T wave during normal sinus rhythm. The defibrillation threshold was determined by a simple step up-down protocol. The upper limit of vulnerability (9.0 ± 4.5 J) did not significantly differ from the defibrillation threshold (9.9 ± 4.0 J), P = NS. A close correlation was present, correlation coefficient = 0.75, P < 0.0001. The upper limit of vulnerability was within 5 J of the defibrillation threshold in 27 (96%) of the 28 patients. The upper limit of vulnerability underestimated the defibrillation threshold by 10 J in one patient who had a defibrillation threshold of 15 J. The upper limit of vulnerability determined in normal sinus rhythm correlates significantly with the defibrillation threshold in patients undergoing ICD implantation. The protocol is simple and easily implemented clinically.

KW - Defibrillation threshold

KW - Implantable cardioverter defibrillator

KW - Upper limit of vulnerability

UR - http://www.scopus.com/inward/record.url?scp=0031969490&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031969490&partnerID=8YFLogxK

U2 - 10.1111/j.1540-8159.1998.tb00124.x

DO - 10.1111/j.1540-8159.1998.tb00124.x

M3 - Article

C2 - 9584298

AN - SCOPUS:0031969490

VL - 21

SP - 687

EP - 693

JO - PACE - Pacing and Clinical Electrophysiology

JF - PACE - Pacing and Clinical Electrophysiology

SN - 0147-8389

IS - 4 I

ER -