TY - JOUR
T1 - Prosthetic Valve Thrombosis
T2 - Diagnosis and Management
AU - Garg, Jalaj
AU - Palaniswamy, Chandrasekar
AU - Pinnamaneni, Sowmya
AU - Sarungbam, Judy
AU - Jain, Diwakar
PY - 2016/1/1
Y1 - 2016/1/1
N2 - St. Jude mechanical prosthesis is the most commonly used prosthetic device with least valvular complications with excellent hemodynamics. However, prosthetic valve thrombosis is one of the serious complications, with rates between 0.03% and 0.13% per patient-year depending on the type of anticoagulation used and compliance to the therapy. Transthoracic echocardiography (TTE) is the initial screening tool (class I) that would provide clues for the assessment of valvular hemodynamics. Fluoroscopy is an alternate imaging modality for the assessment of mechanical leaflet motion, especially in patients when prosthetic valves are difficult to image on TTE or transesophageal echocardiography. A complete fluoroscopic evaluation of a prosthetic valve includes assessment of valvular motion and structural integrity. Opening and closing angles can be measured fluoroscopically to determine whether a specific valve is functioning properly. We discuss a case of a 91-year-old man with thrombosis of bileaflet mechanical mitral prosthesis that was demonstrated on real-time fluoroscopy (not evident on TTE). An algorithmic approach to diagnosis and management of prosthetic heart valve thrombosis is outlined.
AB - St. Jude mechanical prosthesis is the most commonly used prosthetic device with least valvular complications with excellent hemodynamics. However, prosthetic valve thrombosis is one of the serious complications, with rates between 0.03% and 0.13% per patient-year depending on the type of anticoagulation used and compliance to the therapy. Transthoracic echocardiography (TTE) is the initial screening tool (class I) that would provide clues for the assessment of valvular hemodynamics. Fluoroscopy is an alternate imaging modality for the assessment of mechanical leaflet motion, especially in patients when prosthetic valves are difficult to image on TTE or transesophageal echocardiography. A complete fluoroscopic evaluation of a prosthetic valve includes assessment of valvular motion and structural integrity. Opening and closing angles can be measured fluoroscopically to determine whether a specific valve is functioning properly. We discuss a case of a 91-year-old man with thrombosis of bileaflet mechanical mitral prosthesis that was demonstrated on real-time fluoroscopy (not evident on TTE). An algorithmic approach to diagnosis and management of prosthetic heart valve thrombosis is outlined.
KW - fluoroscopy
KW - mitral valve thrombosis
KW - prosthetic valve thrombosis
UR - http://www.scopus.com/inward/record.url?scp=84955752996&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84955752996&partnerID=8YFLogxK
U2 - 10.1097/MJT.0000000000000117
DO - 10.1097/MJT.0000000000000117
M3 - Article
C2 - 25486519
AN - SCOPUS:84955752996
SN - 1075-2765
VL - 23
SP - e252-e255
JO - American Journal of Therapeutics
JF - American Journal of Therapeutics
IS - 1
ER -