Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection

Daniel Juneau, Mohammad Golfam, Samir Hazra, Lionel S. Zuckier, Shady Garas, Calum Redpath, Jordan Bernick, Eugene Leung, Sharon Chih, George Wells, Rob S.B. Beanlands, Benjamin J.W. Chow

Research output: Contribution to journalArticlepeer-review

119 Scopus citations

Abstract

Background - The use of cardiac implantable electronic devices (CIED) is increasing, and their associated infections result in significant morbidity and mortality. The introduction of better cardiac imaging techniques could be useful for diagnosing this condition and guiding therapy. Our objective was to systematically assess the diagnostic accuracy of Fluor-18-fluorodeoxyglucose positron emission tomography and computed tomography, labeled leukocyte scintigraphy (LS), and Gallium-67 citrate scintigraphy for the diagnosis of CIED infection. Methods and Results - A systematic review of the literature and meta-analysis on the use of all 3 modalities in CIED infection were conducted. Pooled sensitivity, specificity, and summary receiver operating characteristic curves of each imaging modalities were determined. The literature search identified 2493 articles. A total of 13 articles (11 studies for 18 F-FDG PET-CT and 2 for LS), met the inclusion criteria. No studies for 67 Ga citrate scintigraphy met the inclusion criteria. The pooled sensitivity of 18 F-FDG PET-CT for the diagnosis of CIED infection was 87% (95% CI, 82%-91%) and pooled specificity was 94% (95% CI, 88%-98%). The summary receiver operating characteristic curve analysis demonstrated good overall accuracy, with an area under the curve of 0.935. There were insufficient data to do a meta-analysis for LS, but both studies reported sensitivity above 90% and specificity of 100%. Conclusions - Both 18 F-FDG PET-CT and LS yield high sensitivity, specificity, and accuracy, and thus seem to be useful for the diagnosis of CIED infection, based on robust data for 18 F-FDG PET-CT but limited data for LS. When available, 18 F-FDG PET-CT may be preferred.

Original languageEnglish (US)
Article numbere005772
JournalCirculation: Cardiovascular Imaging
Volume10
Issue number4
DOIs
StatePublished - Apr 1 2017
Externally publishedYes

Keywords

  • Fluor-18-fluorodeoxyglucose
  • gallium
  • leukocyte
  • positron emission tomography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Positron Emission Tomography and Single-Photon Emission Computed Tomography Imaging in the Diagnosis of Cardiac Implantable Electronic Device Infection'. Together they form a unique fingerprint.

Cite this