Perfusion imaging using FOCI RF pulses

Martin N. Yongbi, Craig A. Branch, Joseph A. Helpern

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

Pulsed arterial spin-tagging techniques for perfusion measurements (e.g., echo planar MR imaging and signal targeting with alternating radiofrequency (EPISTAR), flow-sensitive alternating inversion recovery (FAIR), quantitative imaging of perfusion using a single subtraction (QUIPPS), uninverted FAIR (UNFAIR)) generally use hyperbolic secant (HS) pulses for spin inversion. The performance of these techniques depends on the inversion efficiency, as well as the sharpness of the slice profiles. Frequency offset corrected inversion (FOCI) pulses, a recently proposed HS variant, can provide slice profiles with edges that can be up to 10 times sharper than those obtained with conventional HS pulses. In this communication, the implementation and application of the C-shape FOCI pulse for perfusion imaging in rat brain with the FAIR technique is summarized. Despite providing a more rectangular slice profile than a conventional HS pulse, it is demonstrated both theoretically and experimentally that the FAIR perfusion signal is not increased by using a FOCI tagging pulse. However, the use of a FOCI inversion pulse is shown to significantly minimize static signal subtraction errors that are common with conventional HS pulses. Finally, the suitability of the pulse for perfusion studies is demonstrated, in vivo, on rat brain.

Original languageEnglish (US)
Pages (from-to)938-943
Number of pages6
JournalMagnetic Resonance in Medicine
Volume40
Issue number6
StatePublished - Dec 1998

Fingerprint

Perfusion Imaging
Perfusion
Echo-Planar Imaging
Brain

Keywords

  • FAIR
  • FOCI
  • Hyperbolic secant
  • Perfusion
  • Slice profile

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Yongbi, M. N., Branch, C. A., & Helpern, J. A. (1998). Perfusion imaging using FOCI RF pulses. Magnetic Resonance in Medicine, 40(6), 938-943.

Perfusion imaging using FOCI RF pulses. / Yongbi, Martin N.; Branch, Craig A.; Helpern, Joseph A.

In: Magnetic Resonance in Medicine, Vol. 40, No. 6, 12.1998, p. 938-943.

Research output: Contribution to journalArticle

Yongbi, MN, Branch, CA & Helpern, JA 1998, 'Perfusion imaging using FOCI RF pulses', Magnetic Resonance in Medicine, vol. 40, no. 6, pp. 938-943.
Yongbi, Martin N. ; Branch, Craig A. ; Helpern, Joseph A. / Perfusion imaging using FOCI RF pulses. In: Magnetic Resonance in Medicine. 1998 ; Vol. 40, No. 6. pp. 938-943.
@article{12ce9477e2d742f18579d8997469e2e8,
title = "Perfusion imaging using FOCI RF pulses",
abstract = "Pulsed arterial spin-tagging techniques for perfusion measurements (e.g., echo planar MR imaging and signal targeting with alternating radiofrequency (EPISTAR), flow-sensitive alternating inversion recovery (FAIR), quantitative imaging of perfusion using a single subtraction (QUIPPS), uninverted FAIR (UNFAIR)) generally use hyperbolic secant (HS) pulses for spin inversion. The performance of these techniques depends on the inversion efficiency, as well as the sharpness of the slice profiles. Frequency offset corrected inversion (FOCI) pulses, a recently proposed HS variant, can provide slice profiles with edges that can be up to 10 times sharper than those obtained with conventional HS pulses. In this communication, the implementation and application of the C-shape FOCI pulse for perfusion imaging in rat brain with the FAIR technique is summarized. Despite providing a more rectangular slice profile than a conventional HS pulse, it is demonstrated both theoretically and experimentally that the FAIR perfusion signal is not increased by using a FOCI tagging pulse. However, the use of a FOCI inversion pulse is shown to significantly minimize static signal subtraction errors that are common with conventional HS pulses. Finally, the suitability of the pulse for perfusion studies is demonstrated, in vivo, on rat brain.",
keywords = "FAIR, FOCI, Hyperbolic secant, Perfusion, Slice profile",
author = "Yongbi, {Martin N.} and Branch, {Craig A.} and Helpern, {Joseph A.}",
year = "1998",
month = "12",
language = "English (US)",
volume = "40",
pages = "938--943",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Perfusion imaging using FOCI RF pulses

AU - Yongbi, Martin N.

AU - Branch, Craig A.

AU - Helpern, Joseph A.

PY - 1998/12

Y1 - 1998/12

N2 - Pulsed arterial spin-tagging techniques for perfusion measurements (e.g., echo planar MR imaging and signal targeting with alternating radiofrequency (EPISTAR), flow-sensitive alternating inversion recovery (FAIR), quantitative imaging of perfusion using a single subtraction (QUIPPS), uninverted FAIR (UNFAIR)) generally use hyperbolic secant (HS) pulses for spin inversion. The performance of these techniques depends on the inversion efficiency, as well as the sharpness of the slice profiles. Frequency offset corrected inversion (FOCI) pulses, a recently proposed HS variant, can provide slice profiles with edges that can be up to 10 times sharper than those obtained with conventional HS pulses. In this communication, the implementation and application of the C-shape FOCI pulse for perfusion imaging in rat brain with the FAIR technique is summarized. Despite providing a more rectangular slice profile than a conventional HS pulse, it is demonstrated both theoretically and experimentally that the FAIR perfusion signal is not increased by using a FOCI tagging pulse. However, the use of a FOCI inversion pulse is shown to significantly minimize static signal subtraction errors that are common with conventional HS pulses. Finally, the suitability of the pulse for perfusion studies is demonstrated, in vivo, on rat brain.

AB - Pulsed arterial spin-tagging techniques for perfusion measurements (e.g., echo planar MR imaging and signal targeting with alternating radiofrequency (EPISTAR), flow-sensitive alternating inversion recovery (FAIR), quantitative imaging of perfusion using a single subtraction (QUIPPS), uninverted FAIR (UNFAIR)) generally use hyperbolic secant (HS) pulses for spin inversion. The performance of these techniques depends on the inversion efficiency, as well as the sharpness of the slice profiles. Frequency offset corrected inversion (FOCI) pulses, a recently proposed HS variant, can provide slice profiles with edges that can be up to 10 times sharper than those obtained with conventional HS pulses. In this communication, the implementation and application of the C-shape FOCI pulse for perfusion imaging in rat brain with the FAIR technique is summarized. Despite providing a more rectangular slice profile than a conventional HS pulse, it is demonstrated both theoretically and experimentally that the FAIR perfusion signal is not increased by using a FOCI tagging pulse. However, the use of a FOCI inversion pulse is shown to significantly minimize static signal subtraction errors that are common with conventional HS pulses. Finally, the suitability of the pulse for perfusion studies is demonstrated, in vivo, on rat brain.

KW - FAIR

KW - FOCI

KW - Hyperbolic secant

KW - Perfusion

KW - Slice profile

UR - http://www.scopus.com/inward/record.url?scp=0031753552&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031753552&partnerID=8YFLogxK

M3 - Article

C2 - 9840841

AN - SCOPUS:0031753552

VL - 40

SP - 938

EP - 943

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 6

ER -