TY - JOUR
T1 - Optical imaging technology for body size and shape analysis
T2 - evaluation of a system designed for personal use
AU - Kennedy, Samantha
AU - Hwaung, Phoenix
AU - Kelly, Nisa
AU - Liu, Yong E.
AU - Sobhiyeh, Sima
AU - Heo, Moonseong
AU - Shepherd, John A.
AU - Heymsfield, Steven B.
N1 - Funding Information:
Funding This work was partially supported by two National Institutes of Health NORC Center Grants P30DK072476, Pennington/Louisiana; and P30DK040561, Harvard; and R01DK109008, Shape UP! Adults.
Publisher Copyright:
© 2019, The Author(s), under exclusive licence to Springer Nature Limited.
PY - 2020/6/1
Y1 - 2020/6/1
N2 - Background/Objectives: Three-dimensional optical (3DO) imaging systems that rapidly and accurately provide body shape and composition information are increasingly available in research and clinical settings. Recently, relatively low-cost and space efficient 3DO systems with the ability to report and track individual assessments were introduced to the consumer market for home use. This study critically evaluated the first 3DO imaging device intended for personal operation, the Naked Body Scanner (NBS), against reference methods. Participants/Methods: Circumferences at six standardized anatomic sites were measured with a flexible tape in 90 participants ranging in age (5–74 years), ethnicity, and adiposity. Regression analysis and Bland-Altman plots compared these direct measurements and dual-energy X-ray absorptiometry (DXA) %fat estimates to corresponding NBS values. Method precision was analyzed from duplicate anthropometric and NBS measurements in a subgroup of 51 participants. Results: The NBS exhibited greater variation in test–retest reliability (CV, 0.4–2.7%) between the six measured anatomic locations when compared with manually measured counterparts (0.2–0.4%). All six device-derived circumferences correlated with flexible tape references (R2s, 0.84–0.97; p < 0.0001). Measurement bias was apparent for three anatomic sites while mean differences were present for five. The NBS’s %fat estimates also correlated with DXA results (R2 = 0.73, p < 0.0001) with no significant bias. Conclusions: This system opens a new era of digital home-based assessments that can be incorporated into weight loss or exercise interventions accessible to clinical investigators as well as individual users.
AB - Background/Objectives: Three-dimensional optical (3DO) imaging systems that rapidly and accurately provide body shape and composition information are increasingly available in research and clinical settings. Recently, relatively low-cost and space efficient 3DO systems with the ability to report and track individual assessments were introduced to the consumer market for home use. This study critically evaluated the first 3DO imaging device intended for personal operation, the Naked Body Scanner (NBS), against reference methods. Participants/Methods: Circumferences at six standardized anatomic sites were measured with a flexible tape in 90 participants ranging in age (5–74 years), ethnicity, and adiposity. Regression analysis and Bland-Altman plots compared these direct measurements and dual-energy X-ray absorptiometry (DXA) %fat estimates to corresponding NBS values. Method precision was analyzed from duplicate anthropometric and NBS measurements in a subgroup of 51 participants. Results: The NBS exhibited greater variation in test–retest reliability (CV, 0.4–2.7%) between the six measured anatomic locations when compared with manually measured counterparts (0.2–0.4%). All six device-derived circumferences correlated with flexible tape references (R2s, 0.84–0.97; p < 0.0001). Measurement bias was apparent for three anatomic sites while mean differences were present for five. The NBS’s %fat estimates also correlated with DXA results (R2 = 0.73, p < 0.0001) with no significant bias. Conclusions: This system opens a new era of digital home-based assessments that can be incorporated into weight loss or exercise interventions accessible to clinical investigators as well as individual users.
UR - http://www.scopus.com/inward/record.url?scp=85073925080&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85073925080&partnerID=8YFLogxK
U2 - 10.1038/s41430-019-0501-2
DO - 10.1038/s41430-019-0501-2
M3 - Article
C2 - 31551533
AN - SCOPUS:85073925080
SN - 0954-3007
VL - 74
SP - 920
EP - 929
JO - European Journal of Clinical Nutrition
JF - European Journal of Clinical Nutrition
IS - 6
ER -