On the use of virtual simulation in radiotherapy of the intact breast.

Wolfgang A. Tome, R. A. Steeves, B. P. Paliwal

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

In this paper a method of breast cancer treatment planning using virtual simulation implemented at the Department of Human Oncology at the University of Wisconsin is described. All patients in this procedure are placed in a custom vacuum mold in treatment position with both arms up to avoid collision with the CT scanner aperture. For all patients a CT scan of 5-mm-slice thickness is acquired. The ipsilateral and contralateral breast, the ipsilateral lung and the heart are delineated and a three-dimensional plan is generated that tries to minimize the dose to the ipsilateral lung and heart while ensuring adequate coverage of the affected breast. Digitally reconstructed radiographs are used to verify the patient setup on the treatment machine.

Original languageEnglish (US)
Pages (from-to)58-67
Number of pages10
JournalJournal of applied clinical medical physics / American College of Medical Physics
Volume1
Issue number2
DOIs
StatePublished - Jan 1 2000
Externally publishedYes

Fingerprint

Oncology
Radiotherapy
breast
radiation therapy
Breast
lungs
Computerized tomography
Lung
simulation
Vacuum
Planning
scanners
planning
Arm
Fungi
Therapeutics
apertures
cancer
Breast Neoplasms
dosage

ASJC Scopus subject areas

  • Radiation
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Cite this

On the use of virtual simulation in radiotherapy of the intact breast. / Tome, Wolfgang A.; Steeves, R. A.; Paliwal, B. P.

In: Journal of applied clinical medical physics / American College of Medical Physics, Vol. 1, No. 2, 01.01.2000, p. 58-67.

Research output: Contribution to journalArticle

@article{3be905f01d924a0d96388ba3e4613682,
title = "On the use of virtual simulation in radiotherapy of the intact breast.",
abstract = "In this paper a method of breast cancer treatment planning using virtual simulation implemented at the Department of Human Oncology at the University of Wisconsin is described. All patients in this procedure are placed in a custom vacuum mold in treatment position with both arms up to avoid collision with the CT scanner aperture. For all patients a CT scan of 5-mm-slice thickness is acquired. The ipsilateral and contralateral breast, the ipsilateral lung and the heart are delineated and a three-dimensional plan is generated that tries to minimize the dose to the ipsilateral lung and heart while ensuring adequate coverage of the affected breast. Digitally reconstructed radiographs are used to verify the patient setup on the treatment machine.",
author = "Tome, {Wolfgang A.} and Steeves, {R. A.} and Paliwal, {B. P.}",
year = "2000",
month = "1",
day = "1",
doi = "10.1120/jacmp.v1i2.2646",
language = "English (US)",
volume = "1",
pages = "58--67",
journal = "Journal of Applied Clinical Medical Physics",
issn = "1526-9914",
publisher = "American Institute of Physics Publising LLC",
number = "2",

}

TY - JOUR

T1 - On the use of virtual simulation in radiotherapy of the intact breast.

AU - Tome, Wolfgang A.

AU - Steeves, R. A.

AU - Paliwal, B. P.

PY - 2000/1/1

Y1 - 2000/1/1

N2 - In this paper a method of breast cancer treatment planning using virtual simulation implemented at the Department of Human Oncology at the University of Wisconsin is described. All patients in this procedure are placed in a custom vacuum mold in treatment position with both arms up to avoid collision with the CT scanner aperture. For all patients a CT scan of 5-mm-slice thickness is acquired. The ipsilateral and contralateral breast, the ipsilateral lung and the heart are delineated and a three-dimensional plan is generated that tries to minimize the dose to the ipsilateral lung and heart while ensuring adequate coverage of the affected breast. Digitally reconstructed radiographs are used to verify the patient setup on the treatment machine.

AB - In this paper a method of breast cancer treatment planning using virtual simulation implemented at the Department of Human Oncology at the University of Wisconsin is described. All patients in this procedure are placed in a custom vacuum mold in treatment position with both arms up to avoid collision with the CT scanner aperture. For all patients a CT scan of 5-mm-slice thickness is acquired. The ipsilateral and contralateral breast, the ipsilateral lung and the heart are delineated and a three-dimensional plan is generated that tries to minimize the dose to the ipsilateral lung and heart while ensuring adequate coverage of the affected breast. Digitally reconstructed radiographs are used to verify the patient setup on the treatment machine.

UR - http://www.scopus.com/inward/record.url?scp=85024960402&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85024960402&partnerID=8YFLogxK

U2 - 10.1120/jacmp.v1i2.2646

DO - 10.1120/jacmp.v1i2.2646

M3 - Article

C2 - 11674819

AN - SCOPUS:85024960402

VL - 1

SP - 58

EP - 67

JO - Journal of Applied Clinical Medical Physics

JF - Journal of Applied Clinical Medical Physics

SN - 1526-9914

IS - 2

ER -