On the estimation of the location of the hippocampus in the context of hippocampal avoidance whole brain radiotherapy treatment planning

Edward T. Bender, Minesh P. Mehta, Wolfgang A. Tome

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

We demonstrate a technique for estimating the location of the hippocampus in MRI and CT images for use in radiotherapy treatment planning, using both rigid and contour based deformable image registration. The automatically generated contours can be subsequently modified for a given patient. By mapping the hippocampi from several patients into a template image set, a population-based average hippocampal atlas was generated. Approximate hippocampal contours can be automatically generated in a given image set by mapping this atlas onto it. The performance and accuracy of several atlases generated in different ways was tested on 10 MRI images and 7 CT images. Auto-contouring based on deformable registration significantly outperformed that based on rigid registration alone, with an average Dice similarity score of 0.62 (range .40-.76) for methods utilizing deformation. Comparable results were achieved in auto-contouring CT images when deformable registration was used, demonstrating that the methodology is robust with respect to imaging modality.

Original languageEnglish (US)
Pages (from-to)425-432
Number of pages8
JournalTechnology in Cancer Research and Treatment
Volume8
Issue number6
StatePublished - Dec 2009
Externally publishedYes

Fingerprint

Atlases
Hippocampus
Radiotherapy
Brain
Therapeutics
Population

Keywords

  • Deformable registration
  • Hippocampus
  • MRI
  • Radiotherapy
  • WBRT

ASJC Scopus subject areas

  • Cancer Research
  • Oncology

Cite this

@article{2e86490a102b4924a95f8b301a5c83c1,
title = "On the estimation of the location of the hippocampus in the context of hippocampal avoidance whole brain radiotherapy treatment planning",
abstract = "We demonstrate a technique for estimating the location of the hippocampus in MRI and CT images for use in radiotherapy treatment planning, using both rigid and contour based deformable image registration. The automatically generated contours can be subsequently modified for a given patient. By mapping the hippocampi from several patients into a template image set, a population-based average hippocampal atlas was generated. Approximate hippocampal contours can be automatically generated in a given image set by mapping this atlas onto it. The performance and accuracy of several atlases generated in different ways was tested on 10 MRI images and 7 CT images. Auto-contouring based on deformable registration significantly outperformed that based on rigid registration alone, with an average Dice similarity score of 0.62 (range .40-.76) for methods utilizing deformation. Comparable results were achieved in auto-contouring CT images when deformable registration was used, demonstrating that the methodology is robust with respect to imaging modality.",
keywords = "Deformable registration, Hippocampus, MRI, Radiotherapy, WBRT",
author = "Bender, {Edward T.} and Mehta, {Minesh P.} and Tome, {Wolfgang A.}",
year = "2009",
month = "12",
language = "English (US)",
volume = "8",
pages = "425--432",
journal = "Technology in Cancer Research and Treatment",
issn = "1533-0346",
publisher = "Adenine Press",
number = "6",

}

TY - JOUR

T1 - On the estimation of the location of the hippocampus in the context of hippocampal avoidance whole brain radiotherapy treatment planning

AU - Bender, Edward T.

AU - Mehta, Minesh P.

AU - Tome, Wolfgang A.

PY - 2009/12

Y1 - 2009/12

N2 - We demonstrate a technique for estimating the location of the hippocampus in MRI and CT images for use in radiotherapy treatment planning, using both rigid and contour based deformable image registration. The automatically generated contours can be subsequently modified for a given patient. By mapping the hippocampi from several patients into a template image set, a population-based average hippocampal atlas was generated. Approximate hippocampal contours can be automatically generated in a given image set by mapping this atlas onto it. The performance and accuracy of several atlases generated in different ways was tested on 10 MRI images and 7 CT images. Auto-contouring based on deformable registration significantly outperformed that based on rigid registration alone, with an average Dice similarity score of 0.62 (range .40-.76) for methods utilizing deformation. Comparable results were achieved in auto-contouring CT images when deformable registration was used, demonstrating that the methodology is robust with respect to imaging modality.

AB - We demonstrate a technique for estimating the location of the hippocampus in MRI and CT images for use in radiotherapy treatment planning, using both rigid and contour based deformable image registration. The automatically generated contours can be subsequently modified for a given patient. By mapping the hippocampi from several patients into a template image set, a population-based average hippocampal atlas was generated. Approximate hippocampal contours can be automatically generated in a given image set by mapping this atlas onto it. The performance and accuracy of several atlases generated in different ways was tested on 10 MRI images and 7 CT images. Auto-contouring based on deformable registration significantly outperformed that based on rigid registration alone, with an average Dice similarity score of 0.62 (range .40-.76) for methods utilizing deformation. Comparable results were achieved in auto-contouring CT images when deformable registration was used, demonstrating that the methodology is robust with respect to imaging modality.

KW - Deformable registration

KW - Hippocampus

KW - MRI

KW - Radiotherapy

KW - WBRT

UR - http://www.scopus.com/inward/record.url?scp=74049108960&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=74049108960&partnerID=8YFLogxK

M3 - Article

C2 - 19925026

AN - SCOPUS:74049108960

VL - 8

SP - 425

EP - 432

JO - Technology in Cancer Research and Treatment

JF - Technology in Cancer Research and Treatment

SN - 1533-0346

IS - 6

ER -