On the calculation of mean restricted collision stopping powers

Wolfgang A. Tome, Jatinder R. Palta

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

An analytical method for the calculation of ratios of mean restricted collision stopping powers (L/p)(g)m averaged over the charged particle spectra and the photon spectrum that is accurate to first order has been developed, and it has been explored whether a moderate change in the photon fluence spectrum with field size has an effect on the mean restricted collision stopping power ratio in high-Z materials. The results of this study indicate that for the case of a miniphantom, moderate changes in the photon fluence spectrum have only a weak effect on the ratios of mean restricted collision stopping powers.

Original languageEnglish (US)
Pages (from-to)758-772
Number of pages15
JournalMedical Physics
Volume25
Issue number5
DOIs
StatePublished - May 1998
Externally publishedYes

Fingerprint

Photons

Keywords

  • Calibration
  • Charged particle spectra
  • Collision stopping power
  • Dosimetry
  • Photon spectrum

ASJC Scopus subject areas

  • Biophysics

Cite this

On the calculation of mean restricted collision stopping powers. / Tome, Wolfgang A.; Palta, Jatinder R.

In: Medical Physics, Vol. 25, No. 5, 05.1998, p. 758-772.

Research output: Contribution to journalArticle

Tome, Wolfgang A. ; Palta, Jatinder R. / On the calculation of mean restricted collision stopping powers. In: Medical Physics. 1998 ; Vol. 25, No. 5. pp. 758-772.
@article{b0a3e942a4fe4a6cbc2c681b79c906f9,
title = "On the calculation of mean restricted collision stopping powers",
abstract = "An analytical method for the calculation of ratios of mean restricted collision stopping powers (L/p)(g)m averaged over the charged particle spectra and the photon spectrum that is accurate to first order has been developed, and it has been explored whether a moderate change in the photon fluence spectrum with field size has an effect on the mean restricted collision stopping power ratio in high-Z materials. The results of this study indicate that for the case of a miniphantom, moderate changes in the photon fluence spectrum have only a weak effect on the ratios of mean restricted collision stopping powers.",
keywords = "Calibration, Charged particle spectra, Collision stopping power, Dosimetry, Photon spectrum",
author = "Tome, {Wolfgang A.} and Palta, {Jatinder R.}",
year = "1998",
month = "5",
doi = "10.1118/1.598258",
language = "English (US)",
volume = "25",
pages = "758--772",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "5",

}

TY - JOUR

T1 - On the calculation of mean restricted collision stopping powers

AU - Tome, Wolfgang A.

AU - Palta, Jatinder R.

PY - 1998/5

Y1 - 1998/5

N2 - An analytical method for the calculation of ratios of mean restricted collision stopping powers (L/p)(g)m averaged over the charged particle spectra and the photon spectrum that is accurate to first order has been developed, and it has been explored whether a moderate change in the photon fluence spectrum with field size has an effect on the mean restricted collision stopping power ratio in high-Z materials. The results of this study indicate that for the case of a miniphantom, moderate changes in the photon fluence spectrum have only a weak effect on the ratios of mean restricted collision stopping powers.

AB - An analytical method for the calculation of ratios of mean restricted collision stopping powers (L/p)(g)m averaged over the charged particle spectra and the photon spectrum that is accurate to first order has been developed, and it has been explored whether a moderate change in the photon fluence spectrum with field size has an effect on the mean restricted collision stopping power ratio in high-Z materials. The results of this study indicate that for the case of a miniphantom, moderate changes in the photon fluence spectrum have only a weak effect on the ratios of mean restricted collision stopping powers.

KW - Calibration

KW - Charged particle spectra

KW - Collision stopping power

KW - Dosimetry

KW - Photon spectrum

UR - http://www.scopus.com/inward/record.url?scp=0031860135&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031860135&partnerID=8YFLogxK

U2 - 10.1118/1.598258

DO - 10.1118/1.598258

M3 - Article

VL - 25

SP - 758

EP - 772

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 5

ER -