Myocardial wall velocity assessment by pulsed Doppler tissue imaging

Characteristic findings in normal subjects

Mario J. Garcia, Leonardo Rodriguez, Miguel Ares, Brian P. Griffin, Allan L. Klein, William J. Stewart, James D. Thomas

Research output: Contribution to journalArticle

227 Citations (Scopus)

Abstract

To validate the use of pulsed Doppler tissue imaging that measures myocardial wall velocities and to define the characteristics of these velocities in normal subjects, we obtained and compared the anteroseptal and posterior wall velocities in 24 volunteers with pulsed Doppler tissue imaging and digitized M-mode echocardiography. We also studied the relation between velocity components and hemodynamic events timed by standard Doppler flows. There was an excellent correlation between Doppler and M-mode-derived velocities (r = 0.95, p < 0.001), with higher reproducibility for Doppler (r= 0.99) than for M-mode (r = 0.95, p < 0.001). Biphasic velocities that were uniformly present during isovolumic contraction and relaxation were attributed to geometric changes due to asynchronous contraction and ventricular interdependence. We conclude that wall velocities obtained by pulsed Doppler tissue imaging are accurate and reproducible. This method may prove useful for studying the contractile and elastic properties of the myocardium.

Original languageEnglish (US)
Pages (from-to)648-656
Number of pages9
JournalAmerican Heart Journal
Volume132
Issue number3
DOIs
StatePublished - 1996
Externally publishedYes

Fingerprint

Echocardiography
Volunteers
Myocardium
Hemodynamics

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Myocardial wall velocity assessment by pulsed Doppler tissue imaging : Characteristic findings in normal subjects. / Garcia, Mario J.; Rodriguez, Leonardo; Ares, Miguel; Griffin, Brian P.; Klein, Allan L.; Stewart, William J.; Thomas, James D.

In: American Heart Journal, Vol. 132, No. 3, 1996, p. 648-656.

Research output: Contribution to journalArticle

Garcia, Mario J. ; Rodriguez, Leonardo ; Ares, Miguel ; Griffin, Brian P. ; Klein, Allan L. ; Stewart, William J. ; Thomas, James D. / Myocardial wall velocity assessment by pulsed Doppler tissue imaging : Characteristic findings in normal subjects. In: American Heart Journal. 1996 ; Vol. 132, No. 3. pp. 648-656.
@article{f1fac2a56c9a4e6db2ecebbf82774f90,
title = "Myocardial wall velocity assessment by pulsed Doppler tissue imaging: Characteristic findings in normal subjects",
abstract = "To validate the use of pulsed Doppler tissue imaging that measures myocardial wall velocities and to define the characteristics of these velocities in normal subjects, we obtained and compared the anteroseptal and posterior wall velocities in 24 volunteers with pulsed Doppler tissue imaging and digitized M-mode echocardiography. We also studied the relation between velocity components and hemodynamic events timed by standard Doppler flows. There was an excellent correlation between Doppler and M-mode-derived velocities (r = 0.95, p < 0.001), with higher reproducibility for Doppler (r= 0.99) than for M-mode (r = 0.95, p < 0.001). Biphasic velocities that were uniformly present during isovolumic contraction and relaxation were attributed to geometric changes due to asynchronous contraction and ventricular interdependence. We conclude that wall velocities obtained by pulsed Doppler tissue imaging are accurate and reproducible. This method may prove useful for studying the contractile and elastic properties of the myocardium.",
author = "Garcia, {Mario J.} and Leonardo Rodriguez and Miguel Ares and Griffin, {Brian P.} and Klein, {Allan L.} and Stewart, {William J.} and Thomas, {James D.}",
year = "1996",
doi = "10.1016/S0002-8703(96)90251-3",
language = "English (US)",
volume = "132",
pages = "648--656",
journal = "American Heart Journal",
issn = "0002-8703",
publisher = "Mosby Inc.",
number = "3",

}

TY - JOUR

T1 - Myocardial wall velocity assessment by pulsed Doppler tissue imaging

T2 - Characteristic findings in normal subjects

AU - Garcia, Mario J.

AU - Rodriguez, Leonardo

AU - Ares, Miguel

AU - Griffin, Brian P.

AU - Klein, Allan L.

AU - Stewart, William J.

AU - Thomas, James D.

PY - 1996

Y1 - 1996

N2 - To validate the use of pulsed Doppler tissue imaging that measures myocardial wall velocities and to define the characteristics of these velocities in normal subjects, we obtained and compared the anteroseptal and posterior wall velocities in 24 volunteers with pulsed Doppler tissue imaging and digitized M-mode echocardiography. We also studied the relation between velocity components and hemodynamic events timed by standard Doppler flows. There was an excellent correlation between Doppler and M-mode-derived velocities (r = 0.95, p < 0.001), with higher reproducibility for Doppler (r= 0.99) than for M-mode (r = 0.95, p < 0.001). Biphasic velocities that were uniformly present during isovolumic contraction and relaxation were attributed to geometric changes due to asynchronous contraction and ventricular interdependence. We conclude that wall velocities obtained by pulsed Doppler tissue imaging are accurate and reproducible. This method may prove useful for studying the contractile and elastic properties of the myocardium.

AB - To validate the use of pulsed Doppler tissue imaging that measures myocardial wall velocities and to define the characteristics of these velocities in normal subjects, we obtained and compared the anteroseptal and posterior wall velocities in 24 volunteers with pulsed Doppler tissue imaging and digitized M-mode echocardiography. We also studied the relation between velocity components and hemodynamic events timed by standard Doppler flows. There was an excellent correlation between Doppler and M-mode-derived velocities (r = 0.95, p < 0.001), with higher reproducibility for Doppler (r= 0.99) than for M-mode (r = 0.95, p < 0.001). Biphasic velocities that were uniformly present during isovolumic contraction and relaxation were attributed to geometric changes due to asynchronous contraction and ventricular interdependence. We conclude that wall velocities obtained by pulsed Doppler tissue imaging are accurate and reproducible. This method may prove useful for studying the contractile and elastic properties of the myocardium.

UR - http://www.scopus.com/inward/record.url?scp=0029862559&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029862559&partnerID=8YFLogxK

U2 - 10.1016/S0002-8703(96)90251-3

DO - 10.1016/S0002-8703(96)90251-3

M3 - Article

VL - 132

SP - 648

EP - 656

JO - American Heart Journal

JF - American Heart Journal

SN - 0002-8703

IS - 3

ER -