A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nafion was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nafion film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0×10-9-2.0×10 -8 mol/L and high concentration of 2.5×10-8-5. 0×10-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb2+ ions.

Original languageEnglish (US)
Pages (from-to)1510-1514
Number of pages5
JournalChinese Journal of Chemistry
Volume23
Issue number11
DOIs
StatePublished - Nov 2005
Externally publishedYes

Fingerprint

Multiwalled carbon nanotubes (MWCN)
Glassy carbon
Electrodes
Composite materials
Ions
Nitric Acid
Poisons
Voltammetry
Mercury
Lead
perfluorosulfonic acid
Calibration

Keywords

  • Composite
  • Differential pulsed voltammetry
  • Electrochemistry
  • Lead

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

Lead determination on MWNT/Nafion composite modified glassy carbon electrodes. / Xu, Qin; Liu, Ni Na; Zhu, Jun Jie.

In: Chinese Journal of Chemistry, Vol. 23, No. 11, 11.2005, p. 1510-1514.

Research output: Contribution to journalArticle

Xu, Qin ; Liu, Ni Na ; Zhu, Jun Jie. / Lead determination on MWNT/Nafion composite modified glassy carbon electrodes. In: Chinese Journal of Chemistry. 2005 ; Vol. 23, No. 11. pp. 1510-1514.
@article{ea8885acbe794f49a943c6124eccc10a,
title = "Lead determination on MWNT/Nafion composite modified glassy carbon electrodes",
abstract = "A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nafion was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nafion film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0×10-9-2.0×10 -8 mol/L and high concentration of 2.5×10-8-5. 0×10-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb2+ ions.",
keywords = "Composite, Differential pulsed voltammetry, Electrochemistry, Lead",
author = "Qin Xu and Liu, {Ni Na} and Zhu, {Jun Jie}",
year = "2005",
month = "11",
doi = "10.1002/cjoc.200591510",
language = "English (US)",
volume = "23",
pages = "1510--1514",
journal = "Chinese Journal of Chemistry",
issn = "1001-604X",
publisher = "Shanghai Institute of Organic Chemistry",
number = "11",

}

TY - JOUR

T1 - Lead determination on MWNT/Nafion composite modified glassy carbon electrodes

AU - Xu, Qin

AU - Liu, Ni Na

AU - Zhu, Jun Jie

PY - 2005/11

Y1 - 2005/11

N2 - A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nafion was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nafion film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0×10-9-2.0×10 -8 mol/L and high concentration of 2.5×10-8-5. 0×10-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb2+ ions.

AB - A composite material of nitric acid oxidized multiwalled carbon nanotube (MWNT) and Nafion was prepared. Such composite was modified on a glassy carbon electrode to determine trace of lead by differential pulsed voltammetry. In pH=6.47 NaNO3 solution, Pb2+ ions were accumulated on the modified electrode at -0.4 V. Compared with a bare and a Nafion film coated electrode, the composite coated GC electrode can reduce the accumulating potential and eliminate the toxic character of mercury. The calibration plots were linear at low concentration of 5.0×10-9-2.0×10 -8 mol/L and high concentration of 2.5×10-8-5. 0×10-6 mol/L. The performances characteristics indicate that the electrode can be used to determine trace Pb2+ ions.

KW - Composite

KW - Differential pulsed voltammetry

KW - Electrochemistry

KW - Lead

UR - http://www.scopus.com/inward/record.url?scp=28844466423&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=28844466423&partnerID=8YFLogxK

U2 - 10.1002/cjoc.200591510

DO - 10.1002/cjoc.200591510

M3 - Article

VL - 23

SP - 1510

EP - 1514

JO - Chinese Journal of Chemistry

JF - Chinese Journal of Chemistry

SN - 1001-604X

IS - 11

ER -