Intraprocedural and long-term incomplete occlusion of the left atrial appendage following placement of the WATCHMAN device: A single center experience

Rong Bai, Rodney P. Horton, Luigi Di Biase, Prasant Mohanty, Agnes Pump, Deb Cardinal, Chantel Scallon, Sanghamitra Mohanty, Pasquale Santangeli, Mauricio C. Brantes, Javier Sanchez, J. David Burkhardt, Jason D. Zagrodzky, G. Joseph Gallinghouse, Andrea Natale

Research output: Contribution to journalArticlepeer-review

82 Scopus citations

Abstract

Incomplete LAA Occlusion by WATCHMAN Device. Introduction: Transcatheter left atrial appendage (LAA) closure with the WATCHMAN device has become one of the therapeutic options in atrial fibrillation (AF) patients who are at high risk for ischemic stroke. However, the incidence and evolution of incomplete occlusion of the LAA during and after placement of the WATCHMAN device has not been reported. Methods and Results: Fifty-eight consecutive patients who had undergone WATCHMAN device implant were included in the study. Intraprocedural, 45-day and 12-month transesophageal echocardiogram images were reviewed and analyzed. Peridevice gap was noted in 16 (27.6%), 17 (29.3%), and 20 (34.5%) patients across the 3 time points. Intraprocedural gaps are more likely to be persistent until 12 months and become larger in size over time. New gap also occurs during follow-up even if the LAA was completely sealed at implantation. One patient had an ischemic stroke 4.7 months after implant; another patient developed a left atrial thrombus over the device 21.6 months after implant. Both patients had intraprocedural gap and discontinued warfarin therapy after the 45-day evaluation. Conclusion: Incomplete LAA occlusion with a gap between the WATCHMAN device surface and the LAA wall is relatively common. Intraprocedural gaps are more likely to become bigger over time and persist, while new gaps also occur during follow-up. Further studies are warranted to verify whether the presence and persistence of a peridevice gap is associated with increased risk of thromboembolic event in AF patients implanted with a WATCHMAN device.

Original languageEnglish (US)
Pages (from-to)455-461
Number of pages7
JournalJournal of cardiovascular electrophysiology
Volume23
Issue number5
DOIs
StatePublished - May 2012
Externally publishedYes

Keywords

  • WATCHMAN device
  • atrial fibrillation
  • closure
  • left atrial appendage
  • stroke
  • thrombus

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Fingerprint

Dive into the research topics of 'Intraprocedural and long-term incomplete occlusion of the left atrial appendage following placement of the WATCHMAN device: A single center experience'. Together they form a unique fingerprint.

Cite this