Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

Edwin C I Ao, Nien Yun Wu, Shyh Jen Wang, Na Song, Greta S P Mok

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5?/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (?15.50±5.59)% to (?2.12±1.05)% and (?7.28±2.30)% to (?0.23±0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

Original languageEnglish (US)
Pages (from-to)1060-1070
Number of pages11
JournalMedical Physics
Volume42
Issue number2
DOIs
StatePublished - Feb 1 2015

Fingerprint

Single-Photon Emission-Computed Tomography
Radioisotopes
Organ Size
Spleen
Anatomic Models
Torso
Liver
Nuclear Medicine
Therapeutics
Population

Keywords

  • dosimetry
  • nonrigid registration
  • quantitative SPECT
  • targeted radionuclide therapy

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging
  • Medicine(all)

Cite this

Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images. / Ao, Edwin C I; Wu, Nien Yun; Wang, Shyh Jen; Song, Na; Mok, Greta S P.

In: Medical Physics, Vol. 42, No. 2, 01.02.2015, p. 1060-1070.

Research output: Contribution to journalArticle

Ao, Edwin C I ; Wu, Nien Yun ; Wang, Shyh Jen ; Song, Na ; Mok, Greta S P. / Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images. In: Medical Physics. 2015 ; Vol. 42, No. 2. pp. 1060-1070.
@article{3e242cbc8dd446e4a8a23c7574055db2,
title = "Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images",
abstract = "Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5?/voxels, keeping ≤5{\%} difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (?15.50±5.59){\%} to (?2.12±1.05){\%} and (?7.28±2.30){\%} to (?0.23±0.71){\%} for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79{\%} to 22.70{\%} for liver and 26.00{\%} to 39.70{\%} for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.",
keywords = "dosimetry, nonrigid registration, quantitative SPECT, targeted radionuclide therapy",
author = "Ao, {Edwin C I} and Wu, {Nien Yun} and Wang, {Shyh Jen} and Na Song and Mok, {Greta S P}",
year = "2015",
month = "2",
day = "1",
doi = "10.1118/1.4906242",
language = "English (US)",
volume = "42",
pages = "1060--1070",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "2",

}

TY - JOUR

T1 - Improved dosimetry for targeted radionuclide therapy using nonrigid registration on sequential SPECT images

AU - Ao, Edwin C I

AU - Wu, Nien Yun

AU - Wang, Shyh Jen

AU - Song, Na

AU - Mok, Greta S P

PY - 2015/2/1

Y1 - 2015/2/1

N2 - Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5?/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (?15.50±5.59)% to (?2.12±1.05)% and (?7.28±2.30)% to (?0.23±0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

AB - Purpose: Voxel-level and patient-specific 3D dosimetry for targeted radionuclide therapy (TRT) typically involves serial nuclear medicine scans. Misalignment of the images can result in reduced dosimetric accuracy. Since the scans are typically performed over a period of several days, there will be patient movement between scans and possible nonrigid organ deformation. This work aims to implement and evaluate the use of nonrigid image registration on a series of quantitative SPECT (QSPECT) images for TRT dosimetry. Methods: A population of 4D extended cardiac torso phantoms, comprised of three In-111 Zevalin biokinetics models and three anatomical variations, was generated based on the patient data. The authors simulated QSPECT acquisitions at five time points. At each time point, individual organ and whole-body deformation between scans were modeled by translating/rotating organs and the body up to 5?/voxels, keeping ≤5% difference in organ volume. An analytical projector was used to generate realistic noisy projections for a medium energy general purpose collimator. Projections were reconstructed using OS-EM algorithm with geometric collimator detector response, attenuation, and scatter corrections. The QSPECT images were registered using organ-based nonrigid image registration method. The cumulative activity in each voxel was obtained by integrating the activity over time. Dose distribution images were obtained by convolving the cumulative activity images with a Y-90 dose kernel. Dose volume histograms (DVHs) for organs-of-interest were analyzed. Results: After nonrigid registration, the mean differences in organ doses compared to the case without misalignment were improved from (?15.50±5.59)% to (?2.12±1.05)% and (?7.28±2.30)% to (?0.23±0.71)% for the spleen and liver, respectively. For all organs, the cumulative DVHs showed improvement after nonrigid registration and the normalized absolute error of differential DVHs ranged from 6.79% to 22.70% for liver and 26.00% to 39.70% for spleen with different segmentation methods. Conclusions: These results demonstrated that nonrigid registration of sequential QSPECT images is feasible for TRT and improves the accuracy of 3D dosimetry.

KW - dosimetry

KW - nonrigid registration

KW - quantitative SPECT

KW - targeted radionuclide therapy

UR - http://www.scopus.com/inward/record.url?scp=84923319842&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84923319842&partnerID=8YFLogxK

U2 - 10.1118/1.4906242

DO - 10.1118/1.4906242

M3 - Article

VL - 42

SP - 1060

EP - 1070

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 2

ER -