Abstract
Aims This study compares, from a prospective, observational, non-randomized registry, the post-implant hospitalization rates and associated healthcare resource utilization of cardiac resynchronization therapy-defibrillator (CRT-D) patients with quadripolar (QUAD) vs. bipolar (BIP) left ventricular (LV) leads. Methods and results Between January 2009 and December 2012, 193 consecutive patients receiving de novo CRT-D implants with either a QUAD (n = 116) or a BIP (n = 77) LV lead were enrolled at implant and followed until July 2013 at a single-centre, university hospital. Post-implant hospitalizations related to heart failure (HF) or LV lead surgical revision and associated payer costs were identified using ICD-9-CM diagnosis and procedure codes. Italian national reimbursement rates were determined. Propensity scores were estimated using a logistic regression model based upon 11 pre-implant baseline characteristics and were used to derive a 1: 1 matched cohort of QUAD (n = 77) and BIP (n = 77) patients. Hospitalization rates for the two groups were compared using negative binomial regression and associated payer costs were compared using non-parametric bootstrapping (×10 000) and one-sided hypothesis test. Hospitalization rates of the QUAD group [0.15/ patient (pt)-year] were lower than those of the BIP group (0.32/ pt-year); the incidence rate ratio was 0.46, P = 0.04. The hospitalization costs for the QUAD group (434 ± 128 €/pt-year) were lower than those for the BIP group (1136 ± 362 €/pt-year). The average difference was 718 €/pt-year, P = 0.016. Conclusions In this comparative effectiveness assessment of well-matched groups of CRT-D patients with quadripolar and bipolar LV leads, QUAD patients experienced a lower rate of hospitalizations for HF and LV lead surgical revision, and a lower cost burden. This has important implications for LV pacing lead choice.
Original language | English (US) |
---|---|
Pages (from-to) | 101-107 |
Number of pages | 7 |
Journal | Europace |
Volume | 17 |
Issue number | 1 |
DOIs | |
State | Published - Nov 25 2014 |
Fingerprint
Keywords
- Cardiac resynchronization therapy
- Cost-effectiveness
- Health economics
- Hospitalizations
- Left ventricular lead
- Quadripolar lead
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
- Physiology (medical)
Cite this
Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads : A comparative effectiveness study. / Forleo, Giovanni B.; Di Biase, Luigi; Bharmi, Rupinder; Dalal, Nirav; Panattoni, Germana; Pollastrelli, Annalisa; Tesauro, Manfredi; Santini, Luca; Natale, Andrea; Romeo, Francesco.
In: Europace, Vol. 17, No. 1, 25.11.2014, p. 101-107.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Hospitalization rates and associated cost analysis of cardiac resynchronization therapy with an implantable defibrillator and quadripolar vs. bipolar left ventricular leads
T2 - A comparative effectiveness study
AU - Forleo, Giovanni B.
AU - Di Biase, Luigi
AU - Bharmi, Rupinder
AU - Dalal, Nirav
AU - Panattoni, Germana
AU - Pollastrelli, Annalisa
AU - Tesauro, Manfredi
AU - Santini, Luca
AU - Natale, Andrea
AU - Romeo, Francesco
PY - 2014/11/25
Y1 - 2014/11/25
N2 - Aims This study compares, from a prospective, observational, non-randomized registry, the post-implant hospitalization rates and associated healthcare resource utilization of cardiac resynchronization therapy-defibrillator (CRT-D) patients with quadripolar (QUAD) vs. bipolar (BIP) left ventricular (LV) leads. Methods and results Between January 2009 and December 2012, 193 consecutive patients receiving de novo CRT-D implants with either a QUAD (n = 116) or a BIP (n = 77) LV lead were enrolled at implant and followed until July 2013 at a single-centre, university hospital. Post-implant hospitalizations related to heart failure (HF) or LV lead surgical revision and associated payer costs were identified using ICD-9-CM diagnosis and procedure codes. Italian national reimbursement rates were determined. Propensity scores were estimated using a logistic regression model based upon 11 pre-implant baseline characteristics and were used to derive a 1: 1 matched cohort of QUAD (n = 77) and BIP (n = 77) patients. Hospitalization rates for the two groups were compared using negative binomial regression and associated payer costs were compared using non-parametric bootstrapping (×10 000) and one-sided hypothesis test. Hospitalization rates of the QUAD group [0.15/ patient (pt)-year] were lower than those of the BIP group (0.32/ pt-year); the incidence rate ratio was 0.46, P = 0.04. The hospitalization costs for the QUAD group (434 ± 128 €/pt-year) were lower than those for the BIP group (1136 ± 362 €/pt-year). The average difference was 718 €/pt-year, P = 0.016. Conclusions In this comparative effectiveness assessment of well-matched groups of CRT-D patients with quadripolar and bipolar LV leads, QUAD patients experienced a lower rate of hospitalizations for HF and LV lead surgical revision, and a lower cost burden. This has important implications for LV pacing lead choice.
AB - Aims This study compares, from a prospective, observational, non-randomized registry, the post-implant hospitalization rates and associated healthcare resource utilization of cardiac resynchronization therapy-defibrillator (CRT-D) patients with quadripolar (QUAD) vs. bipolar (BIP) left ventricular (LV) leads. Methods and results Between January 2009 and December 2012, 193 consecutive patients receiving de novo CRT-D implants with either a QUAD (n = 116) or a BIP (n = 77) LV lead were enrolled at implant and followed until July 2013 at a single-centre, university hospital. Post-implant hospitalizations related to heart failure (HF) or LV lead surgical revision and associated payer costs were identified using ICD-9-CM diagnosis and procedure codes. Italian national reimbursement rates were determined. Propensity scores were estimated using a logistic regression model based upon 11 pre-implant baseline characteristics and were used to derive a 1: 1 matched cohort of QUAD (n = 77) and BIP (n = 77) patients. Hospitalization rates for the two groups were compared using negative binomial regression and associated payer costs were compared using non-parametric bootstrapping (×10 000) and one-sided hypothesis test. Hospitalization rates of the QUAD group [0.15/ patient (pt)-year] were lower than those of the BIP group (0.32/ pt-year); the incidence rate ratio was 0.46, P = 0.04. The hospitalization costs for the QUAD group (434 ± 128 €/pt-year) were lower than those for the BIP group (1136 ± 362 €/pt-year). The average difference was 718 €/pt-year, P = 0.016. Conclusions In this comparative effectiveness assessment of well-matched groups of CRT-D patients with quadripolar and bipolar LV leads, QUAD patients experienced a lower rate of hospitalizations for HF and LV lead surgical revision, and a lower cost burden. This has important implications for LV pacing lead choice.
KW - Cardiac resynchronization therapy
KW - Cost-effectiveness
KW - Health economics
KW - Hospitalizations
KW - Left ventricular lead
KW - Quadripolar lead
UR - http://www.scopus.com/inward/record.url?scp=84922464104&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84922464104&partnerID=8YFLogxK
U2 - 10.1093/europace/euu290
DO - 10.1093/europace/euu290
M3 - Article
C2 - 25371428
AN - SCOPUS:84922464104
VL - 17
SP - 101
EP - 107
JO - Europace
JF - Europace
SN - 1099-5129
IS - 1
ER -