Getting to zero: impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation

Bradley C. Clark, Kohei Sumihara, Robert McCarter, Charles I. Berul, Jeffrey P. Moak

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Purpose: Over the past several years, alternative imaging techniques including electroanatomic mapping systems such as CARTO®3 (C3) have been developed to improve anatomic resolution and potentially limit radiation exposure in electrophysiology (EP) procedures. We retrospectively examined the effect of the introduction of C3 on patient radiation exposure during EP studies and ablation procedures at a children’s hospital. Methods: All patients that underwent EP and ablation procedures between January 2012 and August 2015 were included; demographic information, fluoroscopy time (FT), total radiation dose (RAD), and dose-area product (DAP) were collected. Patients were stratified by time period (before vs. after C3 introduction) in three groups: (1) normal heart, (2) congenital heart disease (CHD), and (3) those requiring trans-septal (TS) access. The normal heart group was further separated by arrhythmia diagnosis (accessory pathway (AP), AV nodal reentry tachycardia (AVNRT), atrial, or ventricular arrhythmia). Mean values were compared using a single sample t test, as well as analysis of covariance to control for age, weight, and arrhythmia diagnosis. Results: Mean FT decreased after introduction of C3 in patients in all three patient groups (p < 0.01). When separated by arrhythmia diagnosis, FT decreased in the AP and AVNRT groups (p < 0.0001). After controlling for age, weight, and arrhythmia diagnosis, there was a statistically significant decrease in FT in all three groups and in both RAD and DAP in the normal heart group. Zero fluoroscopy was achieved in 50/159 (31 %) and ≤1 min of FT in 71/159 (45 %) of cases. Conclusions: We have shown a significant decrease in multiple measures of radiation after introduction of C3. Continued refinements are needed to further decrease radiation utilization and achieve the goal of zero fluoroscopy.

Original languageEnglish (US)
Pages (from-to)183-189
Number of pages7
JournalJournal of Interventional Cardiac Electrophysiology
Volume46
Issue number2
DOIs
StatePublished - Aug 1 2016
Externally publishedYes

Fingerprint

Catheter Ablation
Fluoroscopy
Pediatrics
Cardiac Arrhythmias
Electrophysiology
Radiation
Tachycardia
Weights and Measures
Heart Diseases
Demography

Keywords

  • Electroanatomic mapping
  • Electrophysiology
  • Fluoroscopy
  • Pediatric ablation
  • Radiation

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Getting to zero : impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation. / Clark, Bradley C.; Sumihara, Kohei; McCarter, Robert; Berul, Charles I.; Moak, Jeffrey P.

In: Journal of Interventional Cardiac Electrophysiology, Vol. 46, No. 2, 01.08.2016, p. 183-189.

Research output: Contribution to journalArticle

Clark, Bradley C. ; Sumihara, Kohei ; McCarter, Robert ; Berul, Charles I. ; Moak, Jeffrey P. / Getting to zero : impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation. In: Journal of Interventional Cardiac Electrophysiology. 2016 ; Vol. 46, No. 2. pp. 183-189.
@article{40351a8d46dc408db8eaa35b0270eb7b,
title = "Getting to zero: impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation",
abstract = "Purpose: Over the past several years, alternative imaging techniques including electroanatomic mapping systems such as CARTO{\circledR}3 (C3) have been developed to improve anatomic resolution and potentially limit radiation exposure in electrophysiology (EP) procedures. We retrospectively examined the effect of the introduction of C3 on patient radiation exposure during EP studies and ablation procedures at a children’s hospital. Methods: All patients that underwent EP and ablation procedures between January 2012 and August 2015 were included; demographic information, fluoroscopy time (FT), total radiation dose (RAD), and dose-area product (DAP) were collected. Patients were stratified by time period (before vs. after C3 introduction) in three groups: (1) normal heart, (2) congenital heart disease (CHD), and (3) those requiring trans-septal (TS) access. The normal heart group was further separated by arrhythmia diagnosis (accessory pathway (AP), AV nodal reentry tachycardia (AVNRT), atrial, or ventricular arrhythmia). Mean values were compared using a single sample t test, as well as analysis of covariance to control for age, weight, and arrhythmia diagnosis. Results: Mean FT decreased after introduction of C3 in patients in all three patient groups (p < 0.01). When separated by arrhythmia diagnosis, FT decreased in the AP and AVNRT groups (p < 0.0001). After controlling for age, weight, and arrhythmia diagnosis, there was a statistically significant decrease in FT in all three groups and in both RAD and DAP in the normal heart group. Zero fluoroscopy was achieved in 50/159 (31 {\%}) and ≤1 min of FT in 71/159 (45 {\%}) of cases. Conclusions: We have shown a significant decrease in multiple measures of radiation after introduction of C3. Continued refinements are needed to further decrease radiation utilization and achieve the goal of zero fluoroscopy.",
keywords = "Electroanatomic mapping, Electrophysiology, Fluoroscopy, Pediatric ablation, Radiation",
author = "Clark, {Bradley C.} and Kohei Sumihara and Robert McCarter and Berul, {Charles I.} and Moak, {Jeffrey P.}",
year = "2016",
month = "8",
day = "1",
doi = "10.1007/s10840-016-0099-4",
language = "English (US)",
volume = "46",
pages = "183--189",
journal = "Journal of Interventional Cardiac Electrophysiology",
issn = "1383-875X",
publisher = "Springer Netherlands",
number = "2",

}

TY - JOUR

T1 - Getting to zero

T2 - impact of electroanatomical mapping on fluoroscopy use in pediatric catheter ablation

AU - Clark, Bradley C.

AU - Sumihara, Kohei

AU - McCarter, Robert

AU - Berul, Charles I.

AU - Moak, Jeffrey P.

PY - 2016/8/1

Y1 - 2016/8/1

N2 - Purpose: Over the past several years, alternative imaging techniques including electroanatomic mapping systems such as CARTO®3 (C3) have been developed to improve anatomic resolution and potentially limit radiation exposure in electrophysiology (EP) procedures. We retrospectively examined the effect of the introduction of C3 on patient radiation exposure during EP studies and ablation procedures at a children’s hospital. Methods: All patients that underwent EP and ablation procedures between January 2012 and August 2015 were included; demographic information, fluoroscopy time (FT), total radiation dose (RAD), and dose-area product (DAP) were collected. Patients were stratified by time period (before vs. after C3 introduction) in three groups: (1) normal heart, (2) congenital heart disease (CHD), and (3) those requiring trans-septal (TS) access. The normal heart group was further separated by arrhythmia diagnosis (accessory pathway (AP), AV nodal reentry tachycardia (AVNRT), atrial, or ventricular arrhythmia). Mean values were compared using a single sample t test, as well as analysis of covariance to control for age, weight, and arrhythmia diagnosis. Results: Mean FT decreased after introduction of C3 in patients in all three patient groups (p < 0.01). When separated by arrhythmia diagnosis, FT decreased in the AP and AVNRT groups (p < 0.0001). After controlling for age, weight, and arrhythmia diagnosis, there was a statistically significant decrease in FT in all three groups and in both RAD and DAP in the normal heart group. Zero fluoroscopy was achieved in 50/159 (31 %) and ≤1 min of FT in 71/159 (45 %) of cases. Conclusions: We have shown a significant decrease in multiple measures of radiation after introduction of C3. Continued refinements are needed to further decrease radiation utilization and achieve the goal of zero fluoroscopy.

AB - Purpose: Over the past several years, alternative imaging techniques including electroanatomic mapping systems such as CARTO®3 (C3) have been developed to improve anatomic resolution and potentially limit radiation exposure in electrophysiology (EP) procedures. We retrospectively examined the effect of the introduction of C3 on patient radiation exposure during EP studies and ablation procedures at a children’s hospital. Methods: All patients that underwent EP and ablation procedures between January 2012 and August 2015 were included; demographic information, fluoroscopy time (FT), total radiation dose (RAD), and dose-area product (DAP) were collected. Patients were stratified by time period (before vs. after C3 introduction) in three groups: (1) normal heart, (2) congenital heart disease (CHD), and (3) those requiring trans-septal (TS) access. The normal heart group was further separated by arrhythmia diagnosis (accessory pathway (AP), AV nodal reentry tachycardia (AVNRT), atrial, or ventricular arrhythmia). Mean values were compared using a single sample t test, as well as analysis of covariance to control for age, weight, and arrhythmia diagnosis. Results: Mean FT decreased after introduction of C3 in patients in all three patient groups (p < 0.01). When separated by arrhythmia diagnosis, FT decreased in the AP and AVNRT groups (p < 0.0001). After controlling for age, weight, and arrhythmia diagnosis, there was a statistically significant decrease in FT in all three groups and in both RAD and DAP in the normal heart group. Zero fluoroscopy was achieved in 50/159 (31 %) and ≤1 min of FT in 71/159 (45 %) of cases. Conclusions: We have shown a significant decrease in multiple measures of radiation after introduction of C3. Continued refinements are needed to further decrease radiation utilization and achieve the goal of zero fluoroscopy.

KW - Electroanatomic mapping

KW - Electrophysiology

KW - Fluoroscopy

KW - Pediatric ablation

KW - Radiation

UR - http://www.scopus.com/inward/record.url?scp=84954431550&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84954431550&partnerID=8YFLogxK

U2 - 10.1007/s10840-016-0099-4

DO - 10.1007/s10840-016-0099-4

M3 - Article

C2 - 26768435

AN - SCOPUS:84954431550

VL - 46

SP - 183

EP - 189

JO - Journal of Interventional Cardiac Electrophysiology

JF - Journal of Interventional Cardiac Electrophysiology

SN - 1383-875X

IS - 2

ER -