Abstract

Background: This is the first study to examine the effect of acute (24-hour) β-blocker withholding on ventilatory efficiency in patients with advanced chronic heart failure (CHF) during maximal incremental treadmill cardiopulmonary exercise test. Methods and Results: Seventeen CHF patients were studied either 3 hours after administration of β-blocker (BBON) or 27 hours after the last β-blocker ingestion (BBOFF). The ventilatory efficiency was measured via the slope of the linear relationship between ventilation (V′E) and carbon dioxide production (V′CO2) (ie, V′E/V′CO2 slope). Measurements were also made at rest, anaerobic threshold (AT), maximal end-tidal pressure for carbon dioxide (PETCO2max), respiratory compensation point (RC), and peak exercise. Compared with BBON, the V′E/V′CO2 slope was significantly increased during BBOFF (30.8 ± 7.4 vs. 29.1 ± 5.4, P = .04). At peak exercise, oxygen uptake (V′O2, 16.0 ± 2.7 vs. 15.6 ± 2.8 mL·kg·min) and V′CO2 (1458 ± 459 vs. 1414 ± 429 mL/min) were not different between the 2 conditions, whereas V′E was higher during BBOFF (49.5 ± 10.7 vs. 46.1 ± 9.6 L/min, P = .04). No differences were noted at AT and RC in V′O2, V′CO2, V′E, V′E/V′O2, and V′E/V′CO2 ratios during the 2 conditions. At PETCO2max, used to noninvasively estimate the CO2 set point, V′E was higher (33.9 ± 7.6 vs. 31.7 ± 7.3 L/min, P = .002) and PETCO2 was lower (37.4 ± 4.8 vs. 38.5 ± 4.0 mm Hg, P = .03), whereas V′CO2 was unchanged (1079 ± 340 vs. 1050 ± 322 mL/min) during BBOFF. Conclusion: Acute β-blocker withholding resulted in decreased ventilatory efficiency mostly from an increase of V′CO2-independent regulation of V′E and less likely from a change in ventilation/perfusion mismatching.

Original languageEnglish (US)
Pages (from-to)548-555
Number of pages8
JournalJournal of Cardiac Failure
Volume16
Issue number7
DOIs
StatePublished - Jul 2010
Externally publishedYes

Fingerprint

Ventilation
Heart Failure
Anaerobic Threshold
Carbon Dioxide
Exercise
Exercise Test
Perfusion
Eating
Oxygen
Pressure

Keywords

  • β-blocker
  • chronic heart failure
  • exercise capacity
  • ventilatory efficiency

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Effect of Acute β-blocker Withholding on Ventilatory Efficiency in Patients With Advanced Chronic Heart Failure. / Laveneziana, Pierantonio; Agostoni, Piergiuseppe; Mignatti, Andrea; Mushtaq, Saima; Colombo, Paolo; Sims, Daniel B.; Uriel, Nir; Jorde, Ulrich P.

In: Journal of Cardiac Failure, Vol. 16, No. 7, 07.2010, p. 548-555.

Research output: Contribution to journalArticle

Laveneziana, Pierantonio ; Agostoni, Piergiuseppe ; Mignatti, Andrea ; Mushtaq, Saima ; Colombo, Paolo ; Sims, Daniel B. ; Uriel, Nir ; Jorde, Ulrich P. / Effect of Acute β-blocker Withholding on Ventilatory Efficiency in Patients With Advanced Chronic Heart Failure. In: Journal of Cardiac Failure. 2010 ; Vol. 16, No. 7. pp. 548-555.
@article{a292f01391e64cef8a8d29fe2e6bf920,
title = "Effect of Acute β-blocker Withholding on Ventilatory Efficiency in Patients With Advanced Chronic Heart Failure",
abstract = "Background: This is the first study to examine the effect of acute (24-hour) β-blocker withholding on ventilatory efficiency in patients with advanced chronic heart failure (CHF) during maximal incremental treadmill cardiopulmonary exercise test. Methods and Results: Seventeen CHF patients were studied either 3 hours after administration of β-blocker (BBON) or 27 hours after the last β-blocker ingestion (BBOFF). The ventilatory efficiency was measured via the slope of the linear relationship between ventilation (V′E) and carbon dioxide production (V′CO2) (ie, V′E/V′CO2 slope). Measurements were also made at rest, anaerobic threshold (AT), maximal end-tidal pressure for carbon dioxide (PETCO2max), respiratory compensation point (RC), and peak exercise. Compared with BBON, the V′E/V′CO2 slope was significantly increased during BBOFF (30.8 ± 7.4 vs. 29.1 ± 5.4, P = .04). At peak exercise, oxygen uptake (V′O2, 16.0 ± 2.7 vs. 15.6 ± 2.8 mL·kg·min) and V′CO2 (1458 ± 459 vs. 1414 ± 429 mL/min) were not different between the 2 conditions, whereas V′E was higher during BBOFF (49.5 ± 10.7 vs. 46.1 ± 9.6 L/min, P = .04). No differences were noted at AT and RC in V′O2, V′CO2, V′E, V′E/V′O2, and V′E/V′CO2 ratios during the 2 conditions. At PETCO2max, used to noninvasively estimate the CO2 set point, V′E was higher (33.9 ± 7.6 vs. 31.7 ± 7.3 L/min, P = .002) and PETCO2 was lower (37.4 ± 4.8 vs. 38.5 ± 4.0 mm Hg, P = .03), whereas V′CO2 was unchanged (1079 ± 340 vs. 1050 ± 322 mL/min) during BBOFF. Conclusion: Acute β-blocker withholding resulted in decreased ventilatory efficiency mostly from an increase of V′CO2-independent regulation of V′E and less likely from a change in ventilation/perfusion mismatching.",
keywords = "β-blocker, chronic heart failure, exercise capacity, ventilatory efficiency",
author = "Pierantonio Laveneziana and Piergiuseppe Agostoni and Andrea Mignatti and Saima Mushtaq and Paolo Colombo and Sims, {Daniel B.} and Nir Uriel and Jorde, {Ulrich P.}",
year = "2010",
month = "7",
doi = "10.1016/j.cardfail.2010.02.006",
language = "English (US)",
volume = "16",
pages = "548--555",
journal = "Journal of Cardiac Failure",
issn = "1071-9164",
publisher = "Churchill Livingstone",
number = "7",

}

TY - JOUR

T1 - Effect of Acute β-blocker Withholding on Ventilatory Efficiency in Patients With Advanced Chronic Heart Failure

AU - Laveneziana, Pierantonio

AU - Agostoni, Piergiuseppe

AU - Mignatti, Andrea

AU - Mushtaq, Saima

AU - Colombo, Paolo

AU - Sims, Daniel B.

AU - Uriel, Nir

AU - Jorde, Ulrich P.

PY - 2010/7

Y1 - 2010/7

N2 - Background: This is the first study to examine the effect of acute (24-hour) β-blocker withholding on ventilatory efficiency in patients with advanced chronic heart failure (CHF) during maximal incremental treadmill cardiopulmonary exercise test. Methods and Results: Seventeen CHF patients were studied either 3 hours after administration of β-blocker (BBON) or 27 hours after the last β-blocker ingestion (BBOFF). The ventilatory efficiency was measured via the slope of the linear relationship between ventilation (V′E) and carbon dioxide production (V′CO2) (ie, V′E/V′CO2 slope). Measurements were also made at rest, anaerobic threshold (AT), maximal end-tidal pressure for carbon dioxide (PETCO2max), respiratory compensation point (RC), and peak exercise. Compared with BBON, the V′E/V′CO2 slope was significantly increased during BBOFF (30.8 ± 7.4 vs. 29.1 ± 5.4, P = .04). At peak exercise, oxygen uptake (V′O2, 16.0 ± 2.7 vs. 15.6 ± 2.8 mL·kg·min) and V′CO2 (1458 ± 459 vs. 1414 ± 429 mL/min) were not different between the 2 conditions, whereas V′E was higher during BBOFF (49.5 ± 10.7 vs. 46.1 ± 9.6 L/min, P = .04). No differences were noted at AT and RC in V′O2, V′CO2, V′E, V′E/V′O2, and V′E/V′CO2 ratios during the 2 conditions. At PETCO2max, used to noninvasively estimate the CO2 set point, V′E was higher (33.9 ± 7.6 vs. 31.7 ± 7.3 L/min, P = .002) and PETCO2 was lower (37.4 ± 4.8 vs. 38.5 ± 4.0 mm Hg, P = .03), whereas V′CO2 was unchanged (1079 ± 340 vs. 1050 ± 322 mL/min) during BBOFF. Conclusion: Acute β-blocker withholding resulted in decreased ventilatory efficiency mostly from an increase of V′CO2-independent regulation of V′E and less likely from a change in ventilation/perfusion mismatching.

AB - Background: This is the first study to examine the effect of acute (24-hour) β-blocker withholding on ventilatory efficiency in patients with advanced chronic heart failure (CHF) during maximal incremental treadmill cardiopulmonary exercise test. Methods and Results: Seventeen CHF patients were studied either 3 hours after administration of β-blocker (BBON) or 27 hours after the last β-blocker ingestion (BBOFF). The ventilatory efficiency was measured via the slope of the linear relationship between ventilation (V′E) and carbon dioxide production (V′CO2) (ie, V′E/V′CO2 slope). Measurements were also made at rest, anaerobic threshold (AT), maximal end-tidal pressure for carbon dioxide (PETCO2max), respiratory compensation point (RC), and peak exercise. Compared with BBON, the V′E/V′CO2 slope was significantly increased during BBOFF (30.8 ± 7.4 vs. 29.1 ± 5.4, P = .04). At peak exercise, oxygen uptake (V′O2, 16.0 ± 2.7 vs. 15.6 ± 2.8 mL·kg·min) and V′CO2 (1458 ± 459 vs. 1414 ± 429 mL/min) were not different between the 2 conditions, whereas V′E was higher during BBOFF (49.5 ± 10.7 vs. 46.1 ± 9.6 L/min, P = .04). No differences were noted at AT and RC in V′O2, V′CO2, V′E, V′E/V′O2, and V′E/V′CO2 ratios during the 2 conditions. At PETCO2max, used to noninvasively estimate the CO2 set point, V′E was higher (33.9 ± 7.6 vs. 31.7 ± 7.3 L/min, P = .002) and PETCO2 was lower (37.4 ± 4.8 vs. 38.5 ± 4.0 mm Hg, P = .03), whereas V′CO2 was unchanged (1079 ± 340 vs. 1050 ± 322 mL/min) during BBOFF. Conclusion: Acute β-blocker withholding resulted in decreased ventilatory efficiency mostly from an increase of V′CO2-independent regulation of V′E and less likely from a change in ventilation/perfusion mismatching.

KW - β-blocker

KW - chronic heart failure

KW - exercise capacity

KW - ventilatory efficiency

UR - http://www.scopus.com/inward/record.url?scp=77953810023&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953810023&partnerID=8YFLogxK

U2 - 10.1016/j.cardfail.2010.02.006

DO - 10.1016/j.cardfail.2010.02.006

M3 - Article

VL - 16

SP - 548

EP - 555

JO - Journal of Cardiac Failure

JF - Journal of Cardiac Failure

SN - 1071-9164

IS - 7

ER -