CT scans through metal scanning technique versus hardware composition

Nogah Haramati, Ronald B. Staron, Karen Mazel-Sperling, Katherine Freeman, Edward L. Nickoloff, Charles Barax, Frieda Feldman

Research output: Contribution to journalArticle

87 Citations (Scopus)

Abstract

Objective: Streak artifact on CT scans of metal containing areas has been a long standing problem. Although several artifact reducing methods have been used to improve image quality, most have been limited by requiring specialized equipment or lengthy complex calculations that are not automated. Others have shown that increasing the beam energy results in increased thickness of metal that may be imaged by CT without severe image degradation. We have studied the image quality of bone surrounding metal both with titanium and cobalt-chrome prostheses using various scanning techniques. Methods: In a double blind fashion, 28 radiology residents and attendings were surveyed as to the best technique for imaging bone detail surrounding metal. A series of images was arranged of an implanted titanium prosthesis, a cobalt-chrome prosthesis and a pelvis repaired with stainless steel pelvic reconstruction plates. Scans were performed using three techniques: 120 kVp, 170 mA, 2 s, 360° rotation, 140 kVp,140 mA, 3 s, 360° rotation, 140 kVp, 140 mA, 4 s, 420° rotation. Results: Titanium was superior to cobalt-chrome (p <.0001 Wilcoxon Signed Rank Test). No advantage was noted for higher kVp or increased scan arc of 420° compared to the standard 360°. Conclusion: Titanium allows improved bone detail surround the metal than CT cobalt-chrome. We have found no advantage to using either high kVp or a 420° scan are to improve the image quality of bone surrounded by metal.

Original languageEnglish (US)
Pages (from-to)429-434
Number of pages6
JournalComputerized Medical Imaging and Graphics
Volume18
Issue number6
DOIs
StatePublished - 1994

Fingerprint

Computerized tomography
Computer hardware
Metals
Cobalt
Titanium
Scanning
Bone
Chemical analysis
Image quality
Prostheses and Implants
Bone and Bones
Artifacts
Radiology
Stainless Steel
Nonparametric Statistics
Prosthetics
Pelvis
Stainless steel
Imaging techniques
Degradation

Keywords

  • Computed Tomography (CT) artifact
  • Hip prosthesis
  • Metal
  • Prosthesis

ASJC Scopus subject areas

  • Computer Science Applications
  • Radiology Nuclear Medicine and imaging

Cite this

Haramati, N., Staron, R. B., Mazel-Sperling, K., Freeman, K., Nickoloff, E. L., Barax, C., & Feldman, F. (1994). CT scans through metal scanning technique versus hardware composition. Computerized Medical Imaging and Graphics, 18(6), 429-434. https://doi.org/10.1016/0895-6111(94)90080-9

CT scans through metal scanning technique versus hardware composition. / Haramati, Nogah; Staron, Ronald B.; Mazel-Sperling, Karen; Freeman, Katherine; Nickoloff, Edward L.; Barax, Charles; Feldman, Frieda.

In: Computerized Medical Imaging and Graphics, Vol. 18, No. 6, 1994, p. 429-434.

Research output: Contribution to journalArticle

Haramati, N, Staron, RB, Mazel-Sperling, K, Freeman, K, Nickoloff, EL, Barax, C & Feldman, F 1994, 'CT scans through metal scanning technique versus hardware composition', Computerized Medical Imaging and Graphics, vol. 18, no. 6, pp. 429-434. https://doi.org/10.1016/0895-6111(94)90080-9
Haramati, Nogah ; Staron, Ronald B. ; Mazel-Sperling, Karen ; Freeman, Katherine ; Nickoloff, Edward L. ; Barax, Charles ; Feldman, Frieda. / CT scans through metal scanning technique versus hardware composition. In: Computerized Medical Imaging and Graphics. 1994 ; Vol. 18, No. 6. pp. 429-434.
@article{09f541960c71497bbca9540bbe86b3cd,
title = "CT scans through metal scanning technique versus hardware composition",
abstract = "Objective: Streak artifact on CT scans of metal containing areas has been a long standing problem. Although several artifact reducing methods have been used to improve image quality, most have been limited by requiring specialized equipment or lengthy complex calculations that are not automated. Others have shown that increasing the beam energy results in increased thickness of metal that may be imaged by CT without severe image degradation. We have studied the image quality of bone surrounding metal both with titanium and cobalt-chrome prostheses using various scanning techniques. Methods: In a double blind fashion, 28 radiology residents and attendings were surveyed as to the best technique for imaging bone detail surrounding metal. A series of images was arranged of an implanted titanium prosthesis, a cobalt-chrome prosthesis and a pelvis repaired with stainless steel pelvic reconstruction plates. Scans were performed using three techniques: 120 kVp, 170 mA, 2 s, 360° rotation, 140 kVp,140 mA, 3 s, 360° rotation, 140 kVp, 140 mA, 4 s, 420° rotation. Results: Titanium was superior to cobalt-chrome (p <.0001 Wilcoxon Signed Rank Test). No advantage was noted for higher kVp or increased scan arc of 420° compared to the standard 360°. Conclusion: Titanium allows improved bone detail surround the metal than CT cobalt-chrome. We have found no advantage to using either high kVp or a 420° scan are to improve the image quality of bone surrounded by metal.",
keywords = "Computed Tomography (CT) artifact, Hip prosthesis, Metal, Prosthesis",
author = "Nogah Haramati and Staron, {Ronald B.} and Karen Mazel-Sperling and Katherine Freeman and Nickoloff, {Edward L.} and Charles Barax and Frieda Feldman",
year = "1994",
doi = "10.1016/0895-6111(94)90080-9",
language = "English (US)",
volume = "18",
pages = "429--434",
journal = "Computerized Medical Imaging and Graphics",
issn = "0895-6111",
publisher = "Elsevier Limited",
number = "6",

}

TY - JOUR

T1 - CT scans through metal scanning technique versus hardware composition

AU - Haramati, Nogah

AU - Staron, Ronald B.

AU - Mazel-Sperling, Karen

AU - Freeman, Katherine

AU - Nickoloff, Edward L.

AU - Barax, Charles

AU - Feldman, Frieda

PY - 1994

Y1 - 1994

N2 - Objective: Streak artifact on CT scans of metal containing areas has been a long standing problem. Although several artifact reducing methods have been used to improve image quality, most have been limited by requiring specialized equipment or lengthy complex calculations that are not automated. Others have shown that increasing the beam energy results in increased thickness of metal that may be imaged by CT without severe image degradation. We have studied the image quality of bone surrounding metal both with titanium and cobalt-chrome prostheses using various scanning techniques. Methods: In a double blind fashion, 28 radiology residents and attendings were surveyed as to the best technique for imaging bone detail surrounding metal. A series of images was arranged of an implanted titanium prosthesis, a cobalt-chrome prosthesis and a pelvis repaired with stainless steel pelvic reconstruction plates. Scans were performed using three techniques: 120 kVp, 170 mA, 2 s, 360° rotation, 140 kVp,140 mA, 3 s, 360° rotation, 140 kVp, 140 mA, 4 s, 420° rotation. Results: Titanium was superior to cobalt-chrome (p <.0001 Wilcoxon Signed Rank Test). No advantage was noted for higher kVp or increased scan arc of 420° compared to the standard 360°. Conclusion: Titanium allows improved bone detail surround the metal than CT cobalt-chrome. We have found no advantage to using either high kVp or a 420° scan are to improve the image quality of bone surrounded by metal.

AB - Objective: Streak artifact on CT scans of metal containing areas has been a long standing problem. Although several artifact reducing methods have been used to improve image quality, most have been limited by requiring specialized equipment or lengthy complex calculations that are not automated. Others have shown that increasing the beam energy results in increased thickness of metal that may be imaged by CT without severe image degradation. We have studied the image quality of bone surrounding metal both with titanium and cobalt-chrome prostheses using various scanning techniques. Methods: In a double blind fashion, 28 radiology residents and attendings were surveyed as to the best technique for imaging bone detail surrounding metal. A series of images was arranged of an implanted titanium prosthesis, a cobalt-chrome prosthesis and a pelvis repaired with stainless steel pelvic reconstruction plates. Scans were performed using three techniques: 120 kVp, 170 mA, 2 s, 360° rotation, 140 kVp,140 mA, 3 s, 360° rotation, 140 kVp, 140 mA, 4 s, 420° rotation. Results: Titanium was superior to cobalt-chrome (p <.0001 Wilcoxon Signed Rank Test). No advantage was noted for higher kVp or increased scan arc of 420° compared to the standard 360°. Conclusion: Titanium allows improved bone detail surround the metal than CT cobalt-chrome. We have found no advantage to using either high kVp or a 420° scan are to improve the image quality of bone surrounded by metal.

KW - Computed Tomography (CT) artifact

KW - Hip prosthesis

KW - Metal

KW - Prosthesis

UR - http://www.scopus.com/inward/record.url?scp=0028135654&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028135654&partnerID=8YFLogxK

U2 - 10.1016/0895-6111(94)90080-9

DO - 10.1016/0895-6111(94)90080-9

M3 - Article

VL - 18

SP - 429

EP - 434

JO - Computerized Medical Imaging and Graphics

JF - Computerized Medical Imaging and Graphics

SN - 0895-6111

IS - 6

ER -