Complications with 25-gauge and 27-gauge whitacre needles during combined spinal-epidural analgesia in labor

R. Landau, C. F. Ciliberto, S. R. Goodman, S. H. Kim-Lo, R. M. Smiley

Research output: Contribution to journalArticle

25 Citations (Scopus)

Abstract

Needle size and shape may influence the incidence of paresthesias, post-dural puncture headache and other complications during combined spinal-epidural (CSE) procedures. We have noted a relatively high incidence of transient paresthesias during placement of the spinal needle during CSE for labor analgesia. The purpose of this study was to compare the occurrence of paresthesia and post-dural puncture headache in parturients who received CSE analgesia with either a 25-gauge or 27-gauge Whitacre needle. In a prospective observational study, data were gathered from 478 consecutive women receiving labor analgesia. Incidence, duration, and character of any paresthesias upon spinal needle placement and the incidence and treatment of headache were recorded. The incidence of paresthesia with the two needles was similar (16% with 25-gauge vs15.4% with 27 gauge) but the incidence of post-dural puncture headache was higher with the 25-gauge needle (4% vs 0.7% with 27 gauge, P < 0.05). Our data suggest that with Whitacre needles, 27-gauge might be preferable to 25-gauge needles to reduce the rate of post-dural puncture headache in parturients but that they do not alter the incidence of transient paresthesias.

Original languageEnglish (US)
Pages (from-to)168-171
Number of pages4
JournalInternational Journal of Obstetric Anesthesia
Volume10
Issue number3
DOIs
StatePublished - Jan 1 2001
Externally publishedYes

Fingerprint

Epidural Analgesia
Needles
Paresthesia
Post-Dural Puncture Headache
Incidence
Parturition
Analgesia
Observational Studies
Headache
Prospective Studies

ASJC Scopus subject areas

  • Obstetrics and Gynecology
  • Anesthesiology and Pain Medicine

Cite this

Complications with 25-gauge and 27-gauge whitacre needles during combined spinal-epidural analgesia in labor. / Landau, R.; Ciliberto, C. F.; Goodman, S. R.; Kim-Lo, S. H.; Smiley, R. M.

In: International Journal of Obstetric Anesthesia, Vol. 10, No. 3, 01.01.2001, p. 168-171.

Research output: Contribution to journalArticle

Landau, R. ; Ciliberto, C. F. ; Goodman, S. R. ; Kim-Lo, S. H. ; Smiley, R. M. / Complications with 25-gauge and 27-gauge whitacre needles during combined spinal-epidural analgesia in labor. In: International Journal of Obstetric Anesthesia. 2001 ; Vol. 10, No. 3. pp. 168-171.
@article{f2b93e73489849a891c89daaa37a8501,
title = "Complications with 25-gauge and 27-gauge whitacre needles during combined spinal-epidural analgesia in labor",
abstract = "Needle size and shape may influence the incidence of paresthesias, post-dural puncture headache and other complications during combined spinal-epidural (CSE) procedures. We have noted a relatively high incidence of transient paresthesias during placement of the spinal needle during CSE for labor analgesia. The purpose of this study was to compare the occurrence of paresthesia and post-dural puncture headache in parturients who received CSE analgesia with either a 25-gauge or 27-gauge Whitacre needle. In a prospective observational study, data were gathered from 478 consecutive women receiving labor analgesia. Incidence, duration, and character of any paresthesias upon spinal needle placement and the incidence and treatment of headache were recorded. The incidence of paresthesia with the two needles was similar (16{\%} with 25-gauge vs15.4{\%} with 27 gauge) but the incidence of post-dural puncture headache was higher with the 25-gauge needle (4{\%} vs 0.7{\%} with 27 gauge, P < 0.05). Our data suggest that with Whitacre needles, 27-gauge might be preferable to 25-gauge needles to reduce the rate of post-dural puncture headache in parturients but that they do not alter the incidence of transient paresthesias.",
author = "R. Landau and Ciliberto, {C. F.} and Goodman, {S. R.} and Kim-Lo, {S. H.} and Smiley, {R. M.}",
year = "2001",
month = "1",
day = "1",
doi = "10.1054/ijoa.2000.0834",
language = "English (US)",
volume = "10",
pages = "168--171",
journal = "International Journal of Obstetric Anesthesia",
issn = "0959-289X",
publisher = "Churchill Livingstone",
number = "3",

}

TY - JOUR

T1 - Complications with 25-gauge and 27-gauge whitacre needles during combined spinal-epidural analgesia in labor

AU - Landau, R.

AU - Ciliberto, C. F.

AU - Goodman, S. R.

AU - Kim-Lo, S. H.

AU - Smiley, R. M.

PY - 2001/1/1

Y1 - 2001/1/1

N2 - Needle size and shape may influence the incidence of paresthesias, post-dural puncture headache and other complications during combined spinal-epidural (CSE) procedures. We have noted a relatively high incidence of transient paresthesias during placement of the spinal needle during CSE for labor analgesia. The purpose of this study was to compare the occurrence of paresthesia and post-dural puncture headache in parturients who received CSE analgesia with either a 25-gauge or 27-gauge Whitacre needle. In a prospective observational study, data were gathered from 478 consecutive women receiving labor analgesia. Incidence, duration, and character of any paresthesias upon spinal needle placement and the incidence and treatment of headache were recorded. The incidence of paresthesia with the two needles was similar (16% with 25-gauge vs15.4% with 27 gauge) but the incidence of post-dural puncture headache was higher with the 25-gauge needle (4% vs 0.7% with 27 gauge, P < 0.05). Our data suggest that with Whitacre needles, 27-gauge might be preferable to 25-gauge needles to reduce the rate of post-dural puncture headache in parturients but that they do not alter the incidence of transient paresthesias.

AB - Needle size and shape may influence the incidence of paresthesias, post-dural puncture headache and other complications during combined spinal-epidural (CSE) procedures. We have noted a relatively high incidence of transient paresthesias during placement of the spinal needle during CSE for labor analgesia. The purpose of this study was to compare the occurrence of paresthesia and post-dural puncture headache in parturients who received CSE analgesia with either a 25-gauge or 27-gauge Whitacre needle. In a prospective observational study, data were gathered from 478 consecutive women receiving labor analgesia. Incidence, duration, and character of any paresthesias upon spinal needle placement and the incidence and treatment of headache were recorded. The incidence of paresthesia with the two needles was similar (16% with 25-gauge vs15.4% with 27 gauge) but the incidence of post-dural puncture headache was higher with the 25-gauge needle (4% vs 0.7% with 27 gauge, P < 0.05). Our data suggest that with Whitacre needles, 27-gauge might be preferable to 25-gauge needles to reduce the rate of post-dural puncture headache in parturients but that they do not alter the incidence of transient paresthesias.

UR - http://www.scopus.com/inward/record.url?scp=0034935237&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034935237&partnerID=8YFLogxK

U2 - 10.1054/ijoa.2000.0834

DO - 10.1054/ijoa.2000.0834

M3 - Article

VL - 10

SP - 168

EP - 171

JO - International Journal of Obstetric Anesthesia

JF - International Journal of Obstetric Anesthesia

SN - 0959-289X

IS - 3

ER -