T1 - Comparison of Early and Long-Term Outcomes After Transcatheter Aortic Valve Implantation in Patients with New York Heart Association Functional Class IV to those in Class III and Less
AU - Adamo, Marianna
AU - Fiorina, Claudia
AU - Petronio, Anna Sonia
AU - Giannini, Cristina
AU - Tamburino, Corrado
AU - Barbanti, Marco
AU - Bedogni, Francesco
AU - Testa, Luca
AU - Colombo, Antonio
AU - Latib, Azeem
AU - Bruschi, Giuseppe
AU - Reimers, Bernhard
AU - Poli, Arnaldo
AU - Nazzaro, Marco Stefano
AU - Curello, Salvatore
AU - Ettori, Federica
N1 - Publisher Copyright:
© 2018
PY - 2018/11/15
Y1 - 2018/11/15
N2 - Our aim was to investigate the impact of a baseline New York Heart Association (NYHA) class IV on clinical outcomes of a large real-world population who underwent transcatheter aortic valve implantation (TAVI). The primary end points were all-cause mortality, cardiovascular mortality, and re-hospitalization, evaluated at the longest available follow-up and by means of a 3-month landmark analysis. The secondary end points were: change in NYHA class, left ventricular ejection fraction, pulmonary pressure and mitral regurgitation. Out of 2,467 patients, 271 (11%) had a NYHA functional class IV at the admission. The latter had higher Society of Thoracic Surgeons (STS) score (9.2% vs 5.5%; p < 0.001) compared to NYHA ≤ III patients, owing to more comorbidities (prior myocardial infarction, severe long-term kidney disease, atrial fibrillation, left ventricular dysfunction, significant mitral regurgitation, pulmonary hypertension). Device success was similar between the two groups (93.7% vs 94.5%; p = 0.583). At a median follow-up of 15 months (interquartile range 4 to 36 months) a lower freedom from primary end points was observed among NYHA IV versus NYHA ≤ III group (survival from all-cause death: 52% vs 58.4%; p = 0.002; survival from cardiovascular death: 72.5% vs 76.5%; p = 0.091; freedom from re-hospitalization: 81.5% vs 85.4%; p = 0.038). However, after adjustment for baseline imbalance, NYHA IV did not influence the relative risk of long-term primary end points. A 3-month landmark analysis showed that NYHA IV independently predicted 3-month all-cause and cardiovascular mortality (hazard ratio: 1.77; 95% CI [1.10 to 2.83]; p = 0.018 and hazard ratio: 1.64; 95% CI [1.03 to 2.59]; p = 0.036, respectively). Instead, after 3-month follow-up NYHA IV did not affect the risk of primary end points. A significant improvement of the secondary end points was noted in both NYHA IV and NYHA ≤≤ III groups. In conclusion, the presence of NYHA class IV in TAVI candidates was associated to a significant increased risk of mortality within 3 months. Patients with baseline NYHA IV who survived at 3 months had a long-term outcome comparable to that of other subjects. Left ventricular systolic function, pulmonary pressure, and mitral insufficiency significantly improved after TAVI regardless of baseline NYHA class IV.
AB - Our aim was to investigate the impact of a baseline New York Heart Association (NYHA) class IV on clinical outcomes of a large real-world population who underwent transcatheter aortic valve implantation (TAVI). The primary end points were all-cause mortality, cardiovascular mortality, and re-hospitalization, evaluated at the longest available follow-up and by means of a 3-month landmark analysis. The secondary end points were: change in NYHA class, left ventricular ejection fraction, pulmonary pressure and mitral regurgitation. Out of 2,467 patients, 271 (11%) had a NYHA functional class IV at the admission. The latter had higher Society of Thoracic Surgeons (STS) score (9.2% vs 5.5%; p < 0.001) compared to NYHA ≤ III patients, owing to more comorbidities (prior myocardial infarction, severe long-term kidney disease, atrial fibrillation, left ventricular dysfunction, significant mitral regurgitation, pulmonary hypertension). Device success was similar between the two groups (93.7% vs 94.5%; p = 0.583). At a median follow-up of 15 months (interquartile range 4 to 36 months) a lower freedom from primary end points was observed among NYHA IV versus NYHA ≤ III group (survival from all-cause death: 52% vs 58.4%; p = 0.002; survival from cardiovascular death: 72.5% vs 76.5%; p = 0.091; freedom from re-hospitalization: 81.5% vs 85.4%; p = 0.038). However, after adjustment for baseline imbalance, NYHA IV did not influence the relative risk of long-term primary end points. A 3-month landmark analysis showed that NYHA IV independently predicted 3-month all-cause and cardiovascular mortality (hazard ratio: 1.77; 95% CI [1.10 to 2.83]; p = 0.018 and hazard ratio: 1.64; 95% CI [1.03 to 2.59]; p = 0.036, respectively). Instead, after 3-month follow-up NYHA IV did not affect the risk of primary end points. A significant improvement of the secondary end points was noted in both NYHA IV and NYHA ≤≤ III groups. In conclusion, the presence of NYHA class IV in TAVI candidates was associated to a significant increased risk of mortality within 3 months. Patients with baseline NYHA IV who survived at 3 months had a long-term outcome comparable to that of other subjects. Left ventricular systolic function, pulmonary pressure, and mitral insufficiency significantly improved after TAVI regardless of baseline NYHA class IV.
UR - http://www.scopus.com/inward/record.url?scp=85053292039&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85053292039&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2018.08.006
DO - 10.1016/j.amjcard.2018.08.006
M3 - Article
C2 - 30227961
AN - SCOPUS:85053292039
SN - 0002-9149
VL - 122
SP - 1718
EP - 1726
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 10
ER -