Clinical correlates of hand-held ultrasound-guided assessments of the inferior vena cava in patients with acute decompensated heart failure

Soumya Patnaik, Carlos D. Davila, Marvin Lu, Yaser Alhamshari, Mahek Shah, Ulrich P. Jorde, Gregg S. Pressman, Sourin Banerji

Research output: Contribution to journalArticle

Abstract

Background: Accurately assessing volume status in acutely decompensated heart failure (ADHF) can be challenging. Inferior vena cava (IVC) dynamics by echocardiography allow indirect assessment of volume status in these patients. Recently introduced hand-held ultrasound devices are promising. We aimed to describe the clinical correlates of volume status assessment using a hand-held ultrasound device in ADHF. Methods: In this prospective study, we evaluated 106 patients admitted with ADHF. First scan was performed within 24 hours of admission and timed in reference to first dose of intravenous diuretic. Daily resting and inspiratory (sniff) IVC diameters were measured according to standard echocardiography methods during hospitalization including the day of discharge. IVC collapsibility index (IVC-CI = Maximum IVC diameter-Inspiratory IVC diameter/maximum diameter; <0.5 representing hypervolemia) was calculated. Primary study endpoint was 30-day readmission. Research activities were independent of clinical decision-making. Results: Data for 106 patients was analyzed. Mean age was 66.7 ± 13.8 years, of which 53.8% were females, and a mean ejection fraction was 39 ± 18%. Initial scan of the IVC was obtained at an average time of 5.2 ± 8.04 hours from first diuretic dose. 81.2% of patients at admission had an IVC-CI <0.5. 63.2% patients had an IVC-CI <0.5 at discharge. There were no significant differences in age, length of stay, diuretic dose, or 30-day readmissions between patients with a discharge IVC-CI <0.5 vs ≥ 0.5. Conclusion: Hand-held ultrasound assessment of IVC-CI in ADHF patients, although a feasible concept, is unable to predict 30-day readmissions in our study. Further prospective studies are necessary.

Original languageEnglish (US)
JournalEchocardiography
DOIs
StateAccepted/In press - Jan 1 2019

Fingerprint

Inferior Vena Cava
Heart Failure
Hand
Diuretics
Echocardiography
Prospective Studies
Patient Readmission
Equipment and Supplies
Patient Admission
Length of Stay
Hospitalization

Keywords

  • decompensated heart failure
  • diuresis
  • hand-held ultrasound
  • inferior vena cava

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Cite this

Clinical correlates of hand-held ultrasound-guided assessments of the inferior vena cava in patients with acute decompensated heart failure. / Patnaik, Soumya; Davila, Carlos D.; Lu, Marvin; Alhamshari, Yaser; Shah, Mahek; Jorde, Ulrich P.; Pressman, Gregg S.; Banerji, Sourin.

In: Echocardiography, 01.01.2019.

Research output: Contribution to journalArticle

Patnaik, Soumya ; Davila, Carlos D. ; Lu, Marvin ; Alhamshari, Yaser ; Shah, Mahek ; Jorde, Ulrich P. ; Pressman, Gregg S. ; Banerji, Sourin. / Clinical correlates of hand-held ultrasound-guided assessments of the inferior vena cava in patients with acute decompensated heart failure. In: Echocardiography. 2019.
@article{64db4bbcaa3d4ffea0229f10c057f04d,
title = "Clinical correlates of hand-held ultrasound-guided assessments of the inferior vena cava in patients with acute decompensated heart failure",
abstract = "Background: Accurately assessing volume status in acutely decompensated heart failure (ADHF) can be challenging. Inferior vena cava (IVC) dynamics by echocardiography allow indirect assessment of volume status in these patients. Recently introduced hand-held ultrasound devices are promising. We aimed to describe the clinical correlates of volume status assessment using a hand-held ultrasound device in ADHF. Methods: In this prospective study, we evaluated 106 patients admitted with ADHF. First scan was performed within 24 hours of admission and timed in reference to first dose of intravenous diuretic. Daily resting and inspiratory (sniff) IVC diameters were measured according to standard echocardiography methods during hospitalization including the day of discharge. IVC collapsibility index (IVC-CI = Maximum IVC diameter-Inspiratory IVC diameter/maximum diameter; <0.5 representing hypervolemia) was calculated. Primary study endpoint was 30-day readmission. Research activities were independent of clinical decision-making. Results: Data for 106 patients was analyzed. Mean age was 66.7 ± 13.8 years, of which 53.8{\%} were females, and a mean ejection fraction was 39 ± 18{\%}. Initial scan of the IVC was obtained at an average time of 5.2 ± 8.04 hours from first diuretic dose. 81.2{\%} of patients at admission had an IVC-CI <0.5. 63.2{\%} patients had an IVC-CI <0.5 at discharge. There were no significant differences in age, length of stay, diuretic dose, or 30-day readmissions between patients with a discharge IVC-CI <0.5 vs ≥ 0.5. Conclusion: Hand-held ultrasound assessment of IVC-CI in ADHF patients, although a feasible concept, is unable to predict 30-day readmissions in our study. Further prospective studies are necessary.",
keywords = "decompensated heart failure, diuresis, hand-held ultrasound, inferior vena cava",
author = "Soumya Patnaik and Davila, {Carlos D.} and Marvin Lu and Yaser Alhamshari and Mahek Shah and Jorde, {Ulrich P.} and Pressman, {Gregg S.} and Sourin Banerji",
year = "2019",
month = "1",
day = "1",
doi = "10.1111/echo.14551",
language = "English (US)",
journal = "Echocardiography",
issn = "0742-2822",
publisher = "Wiley-Blackwell",

}

TY - JOUR

T1 - Clinical correlates of hand-held ultrasound-guided assessments of the inferior vena cava in patients with acute decompensated heart failure

AU - Patnaik, Soumya

AU - Davila, Carlos D.

AU - Lu, Marvin

AU - Alhamshari, Yaser

AU - Shah, Mahek

AU - Jorde, Ulrich P.

AU - Pressman, Gregg S.

AU - Banerji, Sourin

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Background: Accurately assessing volume status in acutely decompensated heart failure (ADHF) can be challenging. Inferior vena cava (IVC) dynamics by echocardiography allow indirect assessment of volume status in these patients. Recently introduced hand-held ultrasound devices are promising. We aimed to describe the clinical correlates of volume status assessment using a hand-held ultrasound device in ADHF. Methods: In this prospective study, we evaluated 106 patients admitted with ADHF. First scan was performed within 24 hours of admission and timed in reference to first dose of intravenous diuretic. Daily resting and inspiratory (sniff) IVC diameters were measured according to standard echocardiography methods during hospitalization including the day of discharge. IVC collapsibility index (IVC-CI = Maximum IVC diameter-Inspiratory IVC diameter/maximum diameter; <0.5 representing hypervolemia) was calculated. Primary study endpoint was 30-day readmission. Research activities were independent of clinical decision-making. Results: Data for 106 patients was analyzed. Mean age was 66.7 ± 13.8 years, of which 53.8% were females, and a mean ejection fraction was 39 ± 18%. Initial scan of the IVC was obtained at an average time of 5.2 ± 8.04 hours from first diuretic dose. 81.2% of patients at admission had an IVC-CI <0.5. 63.2% patients had an IVC-CI <0.5 at discharge. There were no significant differences in age, length of stay, diuretic dose, or 30-day readmissions between patients with a discharge IVC-CI <0.5 vs ≥ 0.5. Conclusion: Hand-held ultrasound assessment of IVC-CI in ADHF patients, although a feasible concept, is unable to predict 30-day readmissions in our study. Further prospective studies are necessary.

AB - Background: Accurately assessing volume status in acutely decompensated heart failure (ADHF) can be challenging. Inferior vena cava (IVC) dynamics by echocardiography allow indirect assessment of volume status in these patients. Recently introduced hand-held ultrasound devices are promising. We aimed to describe the clinical correlates of volume status assessment using a hand-held ultrasound device in ADHF. Methods: In this prospective study, we evaluated 106 patients admitted with ADHF. First scan was performed within 24 hours of admission and timed in reference to first dose of intravenous diuretic. Daily resting and inspiratory (sniff) IVC diameters were measured according to standard echocardiography methods during hospitalization including the day of discharge. IVC collapsibility index (IVC-CI = Maximum IVC diameter-Inspiratory IVC diameter/maximum diameter; <0.5 representing hypervolemia) was calculated. Primary study endpoint was 30-day readmission. Research activities were independent of clinical decision-making. Results: Data for 106 patients was analyzed. Mean age was 66.7 ± 13.8 years, of which 53.8% were females, and a mean ejection fraction was 39 ± 18%. Initial scan of the IVC was obtained at an average time of 5.2 ± 8.04 hours from first diuretic dose. 81.2% of patients at admission had an IVC-CI <0.5. 63.2% patients had an IVC-CI <0.5 at discharge. There were no significant differences in age, length of stay, diuretic dose, or 30-day readmissions between patients with a discharge IVC-CI <0.5 vs ≥ 0.5. Conclusion: Hand-held ultrasound assessment of IVC-CI in ADHF patients, although a feasible concept, is unable to predict 30-day readmissions in our study. Further prospective studies are necessary.

KW - decompensated heart failure

KW - diuresis

KW - hand-held ultrasound

KW - inferior vena cava

UR - http://www.scopus.com/inward/record.url?scp=85075745372&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85075745372&partnerID=8YFLogxK

U2 - 10.1111/echo.14551

DO - 10.1111/echo.14551

M3 - Article

AN - SCOPUS:85075745372

JO - Echocardiography

JF - Echocardiography

SN - 0742-2822

ER -