Abstract

A goal of clinicians caring for heart transplant recipients has been to use heart rate variability as a noninvasive means of diagnosing graft rejection. The determinants of beat-to-beat variability in the surgically denervated heart have yet to be elucidated. We used an isolated, blood buffer-perfused porcine heart preparation to quantitatively assess the relationship between coronary perfusion and sinus node automaticity. Hearts (n = 9) were suspended in a Langendorff preparation, and heart rate (HR) fluctuations were quantified while perfusion pressure was modulated between 70/50, 80/60, 90/70, and 100/80 mmHg at 0.067 Hz. In 32 of 32 recordings the cross spectrum of perfusion pressure vs. HR showed the largest peak centered at 0.067 Hz. In eight of nine experiments during nonpulsatile perfusion, HR accelerated as perfusion pressure was increased from 40 to 110 mmHg (mean increase 24.2 ± 3.0 beats/min). HR increased 0.34 beats/min per mmHg increase in perfusion pressure (least squares linear regression y = -25.8 mmHg - 0.34x; r = 0.88, P < 0.0001), Administration of low- and high-dose nitroglycerin (Ntg) resulted in a modest increase in flow but produced a significant decrease in HR and blunted the response of HR to changes in perfusion pressure (HR increase 0.26 beats·min-1·mmHg-1, r = 0.87, P < 0.0001 after low-dose Ntg; 0.25 beats·min-1·mmHg-1, r = 0.78, P < 0.0001 after high-dose Ntg). These experiments suggest that sinus node discharge in the isolated perfused heart is mechanically coupled to perfusion pressure on a beat-to-beat basis.

Original languageEnglish (US)
Pages (from-to)694-700
Number of pages7
JournalJournal of Applied Physiology
Volume86
Issue number2
StatePublished - Feb 1999
Externally publishedYes

Fingerprint

Perfusion
Heart Rate
Pressure
Nitroglycerin
Sinoatrial Node
Coronary Sinus
Graft Rejection
Least-Squares Analysis
Linear Models
Buffers
Swine

Keywords

  • Heart rate variability
  • Heart transplantation

ASJC Scopus subject areas

  • Physiology
  • Endocrinology
  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

Slovut, D. P., Wenstrom, J. C., Moeckel, R. B., Salerno, C. T., Park, S. J., & Osborn, J. W. (1999). Beat-to-beat modulation of heart rate is coupled to coronary perfusion pressure in the isolated heart. Journal of Applied Physiology, 86(2), 694-700.

Beat-to-beat modulation of heart rate is coupled to coronary perfusion pressure in the isolated heart. / Slovut, David P.; Wenstrom, John C.; Moeckel, Richard B.; Salerno, Christopher T.; Park, Soon J.; Osborn, John W.

In: Journal of Applied Physiology, Vol. 86, No. 2, 02.1999, p. 694-700.

Research output: Contribution to journalArticle

Slovut, DP, Wenstrom, JC, Moeckel, RB, Salerno, CT, Park, SJ & Osborn, JW 1999, 'Beat-to-beat modulation of heart rate is coupled to coronary perfusion pressure in the isolated heart', Journal of Applied Physiology, vol. 86, no. 2, pp. 694-700.
Slovut, David P. ; Wenstrom, John C. ; Moeckel, Richard B. ; Salerno, Christopher T. ; Park, Soon J. ; Osborn, John W. / Beat-to-beat modulation of heart rate is coupled to coronary perfusion pressure in the isolated heart. In: Journal of Applied Physiology. 1999 ; Vol. 86, No. 2. pp. 694-700.
@article{a9d89fa98fc54b10a7c31b3a2cf788a6,
title = "Beat-to-beat modulation of heart rate is coupled to coronary perfusion pressure in the isolated heart",
abstract = "A goal of clinicians caring for heart transplant recipients has been to use heart rate variability as a noninvasive means of diagnosing graft rejection. The determinants of beat-to-beat variability in the surgically denervated heart have yet to be elucidated. We used an isolated, blood buffer-perfused porcine heart preparation to quantitatively assess the relationship between coronary perfusion and sinus node automaticity. Hearts (n = 9) were suspended in a Langendorff preparation, and heart rate (HR) fluctuations were quantified while perfusion pressure was modulated between 70/50, 80/60, 90/70, and 100/80 mmHg at 0.067 Hz. In 32 of 32 recordings the cross spectrum of perfusion pressure vs. HR showed the largest peak centered at 0.067 Hz. In eight of nine experiments during nonpulsatile perfusion, HR accelerated as perfusion pressure was increased from 40 to 110 mmHg (mean increase 24.2 ± 3.0 beats/min). HR increased 0.34 beats/min per mmHg increase in perfusion pressure (least squares linear regression y = -25.8 mmHg - 0.34x; r = 0.88, P < 0.0001), Administration of low- and high-dose nitroglycerin (Ntg) resulted in a modest increase in flow but produced a significant decrease in HR and blunted the response of HR to changes in perfusion pressure (HR increase 0.26 beats·min-1·mmHg-1, r = 0.87, P < 0.0001 after low-dose Ntg; 0.25 beats·min-1·mmHg-1, r = 0.78, P < 0.0001 after high-dose Ntg). These experiments suggest that sinus node discharge in the isolated perfused heart is mechanically coupled to perfusion pressure on a beat-to-beat basis.",
keywords = "Heart rate variability, Heart transplantation",
author = "Slovut, {David P.} and Wenstrom, {John C.} and Moeckel, {Richard B.} and Salerno, {Christopher T.} and Park, {Soon J.} and Osborn, {John W.}",
year = "1999",
month = "2",
language = "English (US)",
volume = "86",
pages = "694--700",
journal = "Journal of Applied Physiology",
issn = "8750-7587",
publisher = "American Physiological Society",
number = "2",

}

TY - JOUR

T1 - Beat-to-beat modulation of heart rate is coupled to coronary perfusion pressure in the isolated heart

AU - Slovut, David P.

AU - Wenstrom, John C.

AU - Moeckel, Richard B.

AU - Salerno, Christopher T.

AU - Park, Soon J.

AU - Osborn, John W.

PY - 1999/2

Y1 - 1999/2

N2 - A goal of clinicians caring for heart transplant recipients has been to use heart rate variability as a noninvasive means of diagnosing graft rejection. The determinants of beat-to-beat variability in the surgically denervated heart have yet to be elucidated. We used an isolated, blood buffer-perfused porcine heart preparation to quantitatively assess the relationship between coronary perfusion and sinus node automaticity. Hearts (n = 9) were suspended in a Langendorff preparation, and heart rate (HR) fluctuations were quantified while perfusion pressure was modulated between 70/50, 80/60, 90/70, and 100/80 mmHg at 0.067 Hz. In 32 of 32 recordings the cross spectrum of perfusion pressure vs. HR showed the largest peak centered at 0.067 Hz. In eight of nine experiments during nonpulsatile perfusion, HR accelerated as perfusion pressure was increased from 40 to 110 mmHg (mean increase 24.2 ± 3.0 beats/min). HR increased 0.34 beats/min per mmHg increase in perfusion pressure (least squares linear regression y = -25.8 mmHg - 0.34x; r = 0.88, P < 0.0001), Administration of low- and high-dose nitroglycerin (Ntg) resulted in a modest increase in flow but produced a significant decrease in HR and blunted the response of HR to changes in perfusion pressure (HR increase 0.26 beats·min-1·mmHg-1, r = 0.87, P < 0.0001 after low-dose Ntg; 0.25 beats·min-1·mmHg-1, r = 0.78, P < 0.0001 after high-dose Ntg). These experiments suggest that sinus node discharge in the isolated perfused heart is mechanically coupled to perfusion pressure on a beat-to-beat basis.

AB - A goal of clinicians caring for heart transplant recipients has been to use heart rate variability as a noninvasive means of diagnosing graft rejection. The determinants of beat-to-beat variability in the surgically denervated heart have yet to be elucidated. We used an isolated, blood buffer-perfused porcine heart preparation to quantitatively assess the relationship between coronary perfusion and sinus node automaticity. Hearts (n = 9) were suspended in a Langendorff preparation, and heart rate (HR) fluctuations were quantified while perfusion pressure was modulated between 70/50, 80/60, 90/70, and 100/80 mmHg at 0.067 Hz. In 32 of 32 recordings the cross spectrum of perfusion pressure vs. HR showed the largest peak centered at 0.067 Hz. In eight of nine experiments during nonpulsatile perfusion, HR accelerated as perfusion pressure was increased from 40 to 110 mmHg (mean increase 24.2 ± 3.0 beats/min). HR increased 0.34 beats/min per mmHg increase in perfusion pressure (least squares linear regression y = -25.8 mmHg - 0.34x; r = 0.88, P < 0.0001), Administration of low- and high-dose nitroglycerin (Ntg) resulted in a modest increase in flow but produced a significant decrease in HR and blunted the response of HR to changes in perfusion pressure (HR increase 0.26 beats·min-1·mmHg-1, r = 0.87, P < 0.0001 after low-dose Ntg; 0.25 beats·min-1·mmHg-1, r = 0.78, P < 0.0001 after high-dose Ntg). These experiments suggest that sinus node discharge in the isolated perfused heart is mechanically coupled to perfusion pressure on a beat-to-beat basis.

KW - Heart rate variability

KW - Heart transplantation

UR - http://www.scopus.com/inward/record.url?scp=0033053409&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033053409&partnerID=8YFLogxK

M3 - Article

C2 - 9931210

AN - SCOPUS:0033053409

VL - 86

SP - 694

EP - 700

JO - Journal of Applied Physiology

JF - Journal of Applied Physiology

SN - 8750-7587

IS - 2

ER -