TY - JOUR
T1 - A Novel Tripod Percutaneous Reconstruction Technique in Periacetabular Lesions Caused by Metastatic Cancer
AU - Yang, Rui
AU - Goch, Abraham
AU - Murphy, Dennis
AU - Wang, Jichuan
AU - Charubhumi, Vanessa
AU - Fox, Jana
AU - Sen, Milan
AU - Hoang, Bang
AU - Geller, David
N1 - Publisher Copyright:
© 2020 Lippincott Williams and Wilkins. All rights reserved.
PY - 2020/4/1
Y1 - 2020/4/1
N2 - Background:Metastatic lesions in the periacetabular region can cause pain and immobility. Symptomatic patients are often treated surgically with a total hip replacement using various modified Harrington methods. These open surgical procedures confer inherent risks. Prolonged recovery and potential complications may delay adjuvant radiation and systemic therapy.Methods:We describe a novel technique for acetabular reconstruction. Three large-bore cannulated screws are placed percutaneously under fluoroscopy in a tripod configuration to reinforce the mechanical axes of the acetabulum. Increased stability improves pain control and permits weight-bearing.Results:Twenty consecutive patients with periacetabular metastases were treated using the tripod technique. Eighteen patients (90%) had Harrington class-III lesions, and 2 patients had Harrington class-II lesions. The mean surgical time was 2.3 hours. Sixteen patients (80%) were able to get out of bed on postoperative day 1. At 3 months postoperatively, there was significant improvement in pain as documented on their visual analog scale (p < 0.01) and in functionality as measured by the Eastern Cooperative Oncology Group score (p < 0.01). The mean follow-up time was 7 months (range, 0.6 to 20 months). At the most recent follow-up, only 3 among the 16 surviving patients were using opioids chronically for pain. Total hip arthroplasty was performed in 4 patients (20%) in a staged fashion using the previously placed screws as support for a cemented cup and obviating the need for a cage device. Of the 16 patients, 15 could walk either independently (6 patients) or using an ambulatory aid (9 patients). Eight patients with the primary tripod reconstruction survived >6 months postoperatively. They were found to have either new bone formation filling the defects or healing of the pathological fractures. There has been no implant loosening or failure.Conclusions:The tripod technique is a novel application to provide safe and effective pain relief in the context of periacetabular metastatic disease. It can be easily converted to support a cemented acetabular cup for a total hip replacement should disease progression occur. This technique provides an alternative to open surgery as currently practiced in these patients.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
AB - Background:Metastatic lesions in the periacetabular region can cause pain and immobility. Symptomatic patients are often treated surgically with a total hip replacement using various modified Harrington methods. These open surgical procedures confer inherent risks. Prolonged recovery and potential complications may delay adjuvant radiation and systemic therapy.Methods:We describe a novel technique for acetabular reconstruction. Three large-bore cannulated screws are placed percutaneously under fluoroscopy in a tripod configuration to reinforce the mechanical axes of the acetabulum. Increased stability improves pain control and permits weight-bearing.Results:Twenty consecutive patients with periacetabular metastases were treated using the tripod technique. Eighteen patients (90%) had Harrington class-III lesions, and 2 patients had Harrington class-II lesions. The mean surgical time was 2.3 hours. Sixteen patients (80%) were able to get out of bed on postoperative day 1. At 3 months postoperatively, there was significant improvement in pain as documented on their visual analog scale (p < 0.01) and in functionality as measured by the Eastern Cooperative Oncology Group score (p < 0.01). The mean follow-up time was 7 months (range, 0.6 to 20 months). At the most recent follow-up, only 3 among the 16 surviving patients were using opioids chronically for pain. Total hip arthroplasty was performed in 4 patients (20%) in a staged fashion using the previously placed screws as support for a cemented cup and obviating the need for a cage device. Of the 16 patients, 15 could walk either independently (6 patients) or using an ambulatory aid (9 patients). Eight patients with the primary tripod reconstruction survived >6 months postoperatively. They were found to have either new bone formation filling the defects or healing of the pathological fractures. There has been no implant loosening or failure.Conclusions:The tripod technique is a novel application to provide safe and effective pain relief in the context of periacetabular metastatic disease. It can be easily converted to support a cemented acetabular cup for a total hip replacement should disease progression occur. This technique provides an alternative to open surgery as currently practiced in these patients.Level of Evidence:Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
UR - http://www.scopus.com/inward/record.url?scp=85094933158&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85094933158&partnerID=8YFLogxK
U2 - 10.2106/JBJS.19.00936
DO - 10.2106/JBJS.19.00936
M3 - Article
C2 - 32079881
AN - SCOPUS:85094933158
SN - 0021-9355
VL - 102
SP - 592
EP - 599
JO - Journal of Bone and Joint Surgery
JF - Journal of Bone and Joint Surgery
IS - 7
ER -