We report a multivariate curve resolution (MCR)-based spectral deconvolution workflow for untargeted gas chromatography-mass spectrometry metabolomics. As an essential step in preprocessing such data, spectral deconvolution computationally separates ions that are in the same mass spectrum but belong to coeluting compounds that are not resolved completely by chromatography. As a result of this computational separation, spectral deconvolution produces pure fragmentation mass spectra. Traditionally, spectral deconvolution has been achieved by using a model peak approach. We describe the fundamental differences between the model peak-based and the MCR-based spectral deconvolution and report ADAP-GC 4.0 that employs the latter approach while overcoming the associated computational complexity. ADAP-GC 4.0 has been evaluated using GC-TOF data sets from a 27-standards mixture at different dilutions and urine with the mixture spiked in, and GC Orbitrap data sets from mixtures of different standards. It produced the average matching scores 960, 959, and 926 respectively. Moreover, its performance has been compared against MS-DIAL, eRah, and ADAP-GC 3.2, and ADAP-GC 4.0 demonstrated a higher number of matched compounds and up to 6% increase of the average matching score.

Original languageEnglish (US)
Pages (from-to)9069-9077
Number of pages9
JournalAnalytical Chemistry
Volume91
Issue number14
DOIs
StatePublished - Jun 24 2019

Fingerprint

Deconvolution
Gas chromatography
Mass spectrometry
Chromatography
Dilution
Computational complexity
Metabolomics
Ions

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

ADAP-GC 4.0 : Application of Clustering-Assisted Multivariate Curve Resolution to Spectral Deconvolution of Gas Chromatography-Mass Spectrometry Metabolomics Data. / Smirnov, Aleksandr; Qiu, Yunping; Jia, Wei; Walker, Douglas I.; Jones, Dean P.; Du, Xiuxia.

In: Analytical Chemistry, Vol. 91, No. 14, 24.06.2019, p. 9069-9077.

Research output: Contribution to journalArticle

@article{b82e61121e36441bac3b10238be9d125,
title = "ADAP-GC 4.0: Application of Clustering-Assisted Multivariate Curve Resolution to Spectral Deconvolution of Gas Chromatography-Mass Spectrometry Metabolomics Data",
abstract = "We report a multivariate curve resolution (MCR)-based spectral deconvolution workflow for untargeted gas chromatography-mass spectrometry metabolomics. As an essential step in preprocessing such data, spectral deconvolution computationally separates ions that are in the same mass spectrum but belong to coeluting compounds that are not resolved completely by chromatography. As a result of this computational separation, spectral deconvolution produces pure fragmentation mass spectra. Traditionally, spectral deconvolution has been achieved by using a model peak approach. We describe the fundamental differences between the model peak-based and the MCR-based spectral deconvolution and report ADAP-GC 4.0 that employs the latter approach while overcoming the associated computational complexity. ADAP-GC 4.0 has been evaluated using GC-TOF data sets from a 27-standards mixture at different dilutions and urine with the mixture spiked in, and GC Orbitrap data sets from mixtures of different standards. It produced the average matching scores 960, 959, and 926 respectively. Moreover, its performance has been compared against MS-DIAL, eRah, and ADAP-GC 3.2, and ADAP-GC 4.0 demonstrated a higher number of matched compounds and up to 6{\%} increase of the average matching score.",
author = "Aleksandr Smirnov and Yunping Qiu and Wei Jia and Walker, {Douglas I.} and Jones, {Dean P.} and Xiuxia Du",
year = "2019",
month = "6",
day = "24",
doi = "10.1021/acs.analchem.9b01424",
language = "English (US)",
volume = "91",
pages = "9069--9077",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "14",

}

TY - JOUR

T1 - ADAP-GC 4.0

T2 - Application of Clustering-Assisted Multivariate Curve Resolution to Spectral Deconvolution of Gas Chromatography-Mass Spectrometry Metabolomics Data

AU - Smirnov, Aleksandr

AU - Qiu, Yunping

AU - Jia, Wei

AU - Walker, Douglas I.

AU - Jones, Dean P.

AU - Du, Xiuxia

PY - 2019/6/24

Y1 - 2019/6/24

N2 - We report a multivariate curve resolution (MCR)-based spectral deconvolution workflow for untargeted gas chromatography-mass spectrometry metabolomics. As an essential step in preprocessing such data, spectral deconvolution computationally separates ions that are in the same mass spectrum but belong to coeluting compounds that are not resolved completely by chromatography. As a result of this computational separation, spectral deconvolution produces pure fragmentation mass spectra. Traditionally, spectral deconvolution has been achieved by using a model peak approach. We describe the fundamental differences between the model peak-based and the MCR-based spectral deconvolution and report ADAP-GC 4.0 that employs the latter approach while overcoming the associated computational complexity. ADAP-GC 4.0 has been evaluated using GC-TOF data sets from a 27-standards mixture at different dilutions and urine with the mixture spiked in, and GC Orbitrap data sets from mixtures of different standards. It produced the average matching scores 960, 959, and 926 respectively. Moreover, its performance has been compared against MS-DIAL, eRah, and ADAP-GC 3.2, and ADAP-GC 4.0 demonstrated a higher number of matched compounds and up to 6% increase of the average matching score.

AB - We report a multivariate curve resolution (MCR)-based spectral deconvolution workflow for untargeted gas chromatography-mass spectrometry metabolomics. As an essential step in preprocessing such data, spectral deconvolution computationally separates ions that are in the same mass spectrum but belong to coeluting compounds that are not resolved completely by chromatography. As a result of this computational separation, spectral deconvolution produces pure fragmentation mass spectra. Traditionally, spectral deconvolution has been achieved by using a model peak approach. We describe the fundamental differences between the model peak-based and the MCR-based spectral deconvolution and report ADAP-GC 4.0 that employs the latter approach while overcoming the associated computational complexity. ADAP-GC 4.0 has been evaluated using GC-TOF data sets from a 27-standards mixture at different dilutions and urine with the mixture spiked in, and GC Orbitrap data sets from mixtures of different standards. It produced the average matching scores 960, 959, and 926 respectively. Moreover, its performance has been compared against MS-DIAL, eRah, and ADAP-GC 3.2, and ADAP-GC 4.0 demonstrated a higher number of matched compounds and up to 6% increase of the average matching score.

UR - http://www.scopus.com/inward/record.url?scp=85069947884&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85069947884&partnerID=8YFLogxK

U2 - 10.1021/acs.analchem.9b01424

DO - 10.1021/acs.analchem.9b01424

M3 - Article

C2 - 31274283

AN - SCOPUS:85069947884

VL - 91

SP - 9069

EP - 9077

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 14

ER -