TY - JOUR
T1 - A simple method to detect leaks after left atrial appendage occlusion with Watchman
AU - Ayhan, Hüseyin
AU - Mohanty, Sanghamitra
AU - Gedikli, Ömer
AU - Trivedi, Chintan
AU - Canpolat, Ugur
AU - Tapia, Alfredo Chauca
AU - Chen, Qiong
AU - Della Rocca, Domenico G.
AU - Gianni, Carola
AU - Salwan, Anu
AU - Annanab, Alisara
AU - MacDonald, Bryan
AU - Mayedo, Angel
AU - Burkhardt, J. David
AU - Horton, Rodney
AU - Gallinghouse, Gerald J.
AU - Di Biase, Luigi
AU - Al-Ahmad, Amin
AU - Natale, Andrea
N1 - Publisher Copyright:
© 2020 Wiley Periodicals LLC
PY - 2020/9/1
Y1 - 2020/9/1
N2 - Background: We evaluated the efficacy of a new method in identifying peri-device leak (PDL) using morphology of the thrombus formed inside the left atrial appendage (LAA) as seen on follow-up transesophageal echo (TEE). Method: A total of 291 consecutive patients undergoing Watchman procedure were included in this analysis. TEE was performed at 45 days postprocedure. Based on the presence of the thrombus inside the LAA behind the device, patients were grouped as (1) white (W) group: LAA completely filled with thrombus (n = 101), 2) nonwhite (NW) group: LAA completely black or mixed (part black and part white; n = 190). Follow-up TEE was repeated at 6 and 12 months. Results: Baseline characteristics were comparable between groups except the device size, number of patients with chicken-wing morphology, and prevalence of left atrial “smoke” that were significantly higher in the NW group. Detection of black appearance was comparable between the pre-coil closure image and the NW population (26/36 [72.2%] vs 99/154 [64.3%], p =.37). After adjusting for clinically relevant covariates, NW appearance of the LAA was associated with the presence of significant leak (odds ratio: 47.96, 95% confidence interval: 2.91–790.2, p <.001). The 11 patients with mixed appearance at the 6-month TEE remained unchanged (part black and part white) at the 12-month TEE. LAA appearance was white in all 36 patients following coil closure. Conclusion: Our findings demonstrated white and nonwhite appearance of the appendage on TEE to be reliable markers of complete closure and leak respectively, following LAA occlusion with the Watchman device.
AB - Background: We evaluated the efficacy of a new method in identifying peri-device leak (PDL) using morphology of the thrombus formed inside the left atrial appendage (LAA) as seen on follow-up transesophageal echo (TEE). Method: A total of 291 consecutive patients undergoing Watchman procedure were included in this analysis. TEE was performed at 45 days postprocedure. Based on the presence of the thrombus inside the LAA behind the device, patients were grouped as (1) white (W) group: LAA completely filled with thrombus (n = 101), 2) nonwhite (NW) group: LAA completely black or mixed (part black and part white; n = 190). Follow-up TEE was repeated at 6 and 12 months. Results: Baseline characteristics were comparable between groups except the device size, number of patients with chicken-wing morphology, and prevalence of left atrial “smoke” that were significantly higher in the NW group. Detection of black appearance was comparable between the pre-coil closure image and the NW population (26/36 [72.2%] vs 99/154 [64.3%], p =.37). After adjusting for clinically relevant covariates, NW appearance of the LAA was associated with the presence of significant leak (odds ratio: 47.96, 95% confidence interval: 2.91–790.2, p <.001). The 11 patients with mixed appearance at the 6-month TEE remained unchanged (part black and part white) at the 12-month TEE. LAA appearance was white in all 36 patients following coil closure. Conclusion: Our findings demonstrated white and nonwhite appearance of the appendage on TEE to be reliable markers of complete closure and leak respectively, following LAA occlusion with the Watchman device.
KW - Watchman
KW - leak
KW - left atrial appendage (LAA)
KW - thrombus
KW - transoesophageal echocardiography (TEE)
UR - http://www.scopus.com/inward/record.url?scp=85087738637&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85087738637&partnerID=8YFLogxK
U2 - 10.1111/jce.14641
DO - 10.1111/jce.14641
M3 - Article
C2 - 32596864
AN - SCOPUS:85087738637
SN - 1045-3873
VL - 31
SP - 2338
EP - 2343
JO - Journal of Cardiovascular Electrophysiology
JF - Journal of Cardiovascular Electrophysiology
IS - 9
ER -