A novel technique for reducing intertrochanteric hip fractures

Anthony A ndrés R DePalma, Kevin O'Halloran, Kartik Shenoy, Konrad I. Gruson, Alok D. Sharan

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Intertrochanteric hip fractures typically become deformed by the muscular and gravitational forces acting on the 2 main bony fragments. Traditional use of a fracture table for anatomical reduction normally corrects for the varus angulation, external rotation, and posterior sag that can occur, but, in select unstable and comminuted fractures, reduction may not be possible because of posterior sag and external rotation of the proximal fragment. These aspects of malreduction have been addressed in multiple ways, including use of unscrubbed assistants, crutches, internal rotation of the distal fragment by internal rotation of the foot, bumps and pads, and even intraoperative techniques. However, these techniques tend to adjust only 1 aspect of malreduction and may require intraoperative adjustment. In this article, we describe a novel surgical device, the pneumatic patient positioner, that can be used to address these deformities without the need for intraoperative adjustment.

Original languageEnglish (US)
Pages (from-to)402-404
Number of pages3
JournalAmerican journal of orthopedics (Belle Mead, N.J.)
Volume43
Issue number9
StatePublished - Sep 1 2014
Externally publishedYes

Fingerprint

Hip Fractures
Crutches
Comminuted Fractures
Fracture Fixation
Foot
Equipment and Supplies

ASJC Scopus subject areas

  • Medicine(all)

Cite this

DePalma, A. A. N. R., O'Halloran, K., Shenoy, K., Gruson, K. I., & Sharan, A. D. (2014). A novel technique for reducing intertrochanteric hip fractures. American journal of orthopedics (Belle Mead, N.J.), 43(9), 402-404.

A novel technique for reducing intertrochanteric hip fractures. / DePalma, Anthony A ndrés R; O'Halloran, Kevin; Shenoy, Kartik; Gruson, Konrad I.; Sharan, Alok D.

In: American journal of orthopedics (Belle Mead, N.J.), Vol. 43, No. 9, 01.09.2014, p. 402-404.

Research output: Contribution to journalArticle

DePalma, AANR, O'Halloran, K, Shenoy, K, Gruson, KI & Sharan, AD 2014, 'A novel technique for reducing intertrochanteric hip fractures', American journal of orthopedics (Belle Mead, N.J.), vol. 43, no. 9, pp. 402-404.
DePalma, Anthony A ndrés R ; O'Halloran, Kevin ; Shenoy, Kartik ; Gruson, Konrad I. ; Sharan, Alok D. / A novel technique for reducing intertrochanteric hip fractures. In: American journal of orthopedics (Belle Mead, N.J.). 2014 ; Vol. 43, No. 9. pp. 402-404.
@article{dacbb23c7aab49ddb311a836c8980e14,
title = "A novel technique for reducing intertrochanteric hip fractures",
abstract = "Intertrochanteric hip fractures typically become deformed by the muscular and gravitational forces acting on the 2 main bony fragments. Traditional use of a fracture table for anatomical reduction normally corrects for the varus angulation, external rotation, and posterior sag that can occur, but, in select unstable and comminuted fractures, reduction may not be possible because of posterior sag and external rotation of the proximal fragment. These aspects of malreduction have been addressed in multiple ways, including use of unscrubbed assistants, crutches, internal rotation of the distal fragment by internal rotation of the foot, bumps and pads, and even intraoperative techniques. However, these techniques tend to adjust only 1 aspect of malreduction and may require intraoperative adjustment. In this article, we describe a novel surgical device, the pneumatic patient positioner, that can be used to address these deformities without the need for intraoperative adjustment.",
author = "DePalma, {Anthony A ndr{\'e}s R} and Kevin O'Halloran and Kartik Shenoy and Gruson, {Konrad I.} and Sharan, {Alok D.}",
year = "2014",
month = "9",
day = "1",
language = "English (US)",
volume = "43",
pages = "402--404",
journal = "American Journal of Orthopedics",
issn = "1078-4519",
publisher = "Quadrant Healthcom Inc.",
number = "9",

}

TY - JOUR

T1 - A novel technique for reducing intertrochanteric hip fractures

AU - DePalma, Anthony A ndrés R

AU - O'Halloran, Kevin

AU - Shenoy, Kartik

AU - Gruson, Konrad I.

AU - Sharan, Alok D.

PY - 2014/9/1

Y1 - 2014/9/1

N2 - Intertrochanteric hip fractures typically become deformed by the muscular and gravitational forces acting on the 2 main bony fragments. Traditional use of a fracture table for anatomical reduction normally corrects for the varus angulation, external rotation, and posterior sag that can occur, but, in select unstable and comminuted fractures, reduction may not be possible because of posterior sag and external rotation of the proximal fragment. These aspects of malreduction have been addressed in multiple ways, including use of unscrubbed assistants, crutches, internal rotation of the distal fragment by internal rotation of the foot, bumps and pads, and even intraoperative techniques. However, these techniques tend to adjust only 1 aspect of malreduction and may require intraoperative adjustment. In this article, we describe a novel surgical device, the pneumatic patient positioner, that can be used to address these deformities without the need for intraoperative adjustment.

AB - Intertrochanteric hip fractures typically become deformed by the muscular and gravitational forces acting on the 2 main bony fragments. Traditional use of a fracture table for anatomical reduction normally corrects for the varus angulation, external rotation, and posterior sag that can occur, but, in select unstable and comminuted fractures, reduction may not be possible because of posterior sag and external rotation of the proximal fragment. These aspects of malreduction have been addressed in multiple ways, including use of unscrubbed assistants, crutches, internal rotation of the distal fragment by internal rotation of the foot, bumps and pads, and even intraoperative techniques. However, these techniques tend to adjust only 1 aspect of malreduction and may require intraoperative adjustment. In this article, we describe a novel surgical device, the pneumatic patient positioner, that can be used to address these deformities without the need for intraoperative adjustment.

UR - http://www.scopus.com/inward/record.url?scp=84930788855&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84930788855&partnerID=8YFLogxK

M3 - Article

C2 - 25251524

AN - SCOPUS:84930788855

VL - 43

SP - 402

EP - 404

JO - American Journal of Orthopedics

JF - American Journal of Orthopedics

SN - 1078-4519

IS - 9

ER -