A novel system to generate WTC dust particles for inhalation exposures

Joshua M. Vaughan, Brittany J. Garrett, Colette M. Prophete, Lori Horton, Maureen Sisco, Joleen M. Soukup, Judith T. Zelikoff, Andrew Ghio, Richard E. Peltier, Bahman Asgharian, Lung Chi Chen, Mitchell D. Cohen

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

First responders (FRs) present at Ground Zero within the critical first 72 h after the World Trade Center (WTC) collapse have progressively exhibited significant respiratory injury. The majority (>96%) of WTC dusts were >10 μm and no studies have examined potential health effects of this size fraction. This study sought to develop a system to generate and deliver supercoarse (10-53 μm) WTC particles to a rat model in a manner that mimicked FR exposure scenarios. A modified Fishing Line generator was integrated onto an intratracheal inhalation (ITIH) system that allowed for a bypassing of the nasal passages so as to mimic FR exposures. Dust concentrations were measured gravimetrically; particle size distribution was measured via elutriation. Results indicate that the system could produce dusts with 23 μm mass median aerodynamic diameter (MMAD) at levels up to ≥1200 mg/m 3. To validate system utility, F344 rats were exposed for 2 h to ≈100 mg WTC dust/m 3. Exposed rats had significantly increased lung weight and levels of select tracer metals 1 h after exposure. Using this system, it is now possible to conduct relevant inhalation exposures to determine adverse WTC dusts impacts on the respiratory system. Furthermore, this novel integrated Fishing Line-ITIH system could potentially be used in the analyses of a wide spectrum of other dusts/pollutants of sizes previously untested or delivered to the lungs in ways that did not reflect realistic exposure scenarios.

Original languageEnglish (US)
Pages (from-to)105-112
Number of pages8
JournalJournal of Exposure Science and Environmental Epidemiology
Volume24
Issue number1
DOIs
StatePublished - Jan 2014

Fingerprint

Inhalation Exposure
Dust
Particles (particulate matter)
Rats
Inhalation
Respiratory system
Lung
Inbred F344 Rats
Nose
Particle Size
Particle size analysis
Respiratory System
Aerodynamics
Metals
Health
Weights and Measures
Wounds and Injuries

Keywords

  • Dust
  • Fishing line
  • Generator
  • Intratracheal inhalation
  • World Trade Center
  • WTC

ASJC Scopus subject areas

  • Pollution
  • Public Health, Environmental and Occupational Health
  • Toxicology
  • Epidemiology

Cite this

A novel system to generate WTC dust particles for inhalation exposures. / Vaughan, Joshua M.; Garrett, Brittany J.; Prophete, Colette M.; Horton, Lori; Sisco, Maureen; Soukup, Joleen M.; Zelikoff, Judith T.; Ghio, Andrew; Peltier, Richard E.; Asgharian, Bahman; Chen, Lung Chi; Cohen, Mitchell D.

In: Journal of Exposure Science and Environmental Epidemiology, Vol. 24, No. 1, 01.2014, p. 105-112.

Research output: Contribution to journalArticle

Vaughan, JM, Garrett, BJ, Prophete, CM, Horton, L, Sisco, M, Soukup, JM, Zelikoff, JT, Ghio, A, Peltier, RE, Asgharian, B, Chen, LC & Cohen, MD 2014, 'A novel system to generate WTC dust particles for inhalation exposures', Journal of Exposure Science and Environmental Epidemiology, vol. 24, no. 1, pp. 105-112. https://doi.org/10.1038/jes.2013.68
Vaughan, Joshua M. ; Garrett, Brittany J. ; Prophete, Colette M. ; Horton, Lori ; Sisco, Maureen ; Soukup, Joleen M. ; Zelikoff, Judith T. ; Ghio, Andrew ; Peltier, Richard E. ; Asgharian, Bahman ; Chen, Lung Chi ; Cohen, Mitchell D. / A novel system to generate WTC dust particles for inhalation exposures. In: Journal of Exposure Science and Environmental Epidemiology. 2014 ; Vol. 24, No. 1. pp. 105-112.
@article{dc359e2ed3d6406895c3cd35fea3d9ac,
title = "A novel system to generate WTC dust particles for inhalation exposures",
abstract = "First responders (FRs) present at Ground Zero within the critical first 72 h after the World Trade Center (WTC) collapse have progressively exhibited significant respiratory injury. The majority (>96{\%}) of WTC dusts were >10 μm and no studies have examined potential health effects of this size fraction. This study sought to develop a system to generate and deliver supercoarse (10-53 μm) WTC particles to a rat model in a manner that mimicked FR exposure scenarios. A modified Fishing Line generator was integrated onto an intratracheal inhalation (ITIH) system that allowed for a bypassing of the nasal passages so as to mimic FR exposures. Dust concentrations were measured gravimetrically; particle size distribution was measured via elutriation. Results indicate that the system could produce dusts with 23 μm mass median aerodynamic diameter (MMAD) at levels up to ≥1200 mg/m 3. To validate system utility, F344 rats were exposed for 2 h to ≈100 mg WTC dust/m 3. Exposed rats had significantly increased lung weight and levels of select tracer metals 1 h after exposure. Using this system, it is now possible to conduct relevant inhalation exposures to determine adverse WTC dusts impacts on the respiratory system. Furthermore, this novel integrated Fishing Line-ITIH system could potentially be used in the analyses of a wide spectrum of other dusts/pollutants of sizes previously untested or delivered to the lungs in ways that did not reflect realistic exposure scenarios.",
keywords = "Dust, Fishing line, Generator, Intratracheal inhalation, World Trade Center, WTC",
author = "Vaughan, {Joshua M.} and Garrett, {Brittany J.} and Prophete, {Colette M.} and Lori Horton and Maureen Sisco and Soukup, {Joleen M.} and Zelikoff, {Judith T.} and Andrew Ghio and Peltier, {Richard E.} and Bahman Asgharian and Chen, {Lung Chi} and Cohen, {Mitchell D.}",
year = "2014",
month = "1",
doi = "10.1038/jes.2013.68",
language = "English (US)",
volume = "24",
pages = "105--112",
journal = "Journal of Exposure Science and Environmental Epidemiology",
issn = "1559-0631",
publisher = "Nature Publishing Group",
number = "1",

}

TY - JOUR

T1 - A novel system to generate WTC dust particles for inhalation exposures

AU - Vaughan, Joshua M.

AU - Garrett, Brittany J.

AU - Prophete, Colette M.

AU - Horton, Lori

AU - Sisco, Maureen

AU - Soukup, Joleen M.

AU - Zelikoff, Judith T.

AU - Ghio, Andrew

AU - Peltier, Richard E.

AU - Asgharian, Bahman

AU - Chen, Lung Chi

AU - Cohen, Mitchell D.

PY - 2014/1

Y1 - 2014/1

N2 - First responders (FRs) present at Ground Zero within the critical first 72 h after the World Trade Center (WTC) collapse have progressively exhibited significant respiratory injury. The majority (>96%) of WTC dusts were >10 μm and no studies have examined potential health effects of this size fraction. This study sought to develop a system to generate and deliver supercoarse (10-53 μm) WTC particles to a rat model in a manner that mimicked FR exposure scenarios. A modified Fishing Line generator was integrated onto an intratracheal inhalation (ITIH) system that allowed for a bypassing of the nasal passages so as to mimic FR exposures. Dust concentrations were measured gravimetrically; particle size distribution was measured via elutriation. Results indicate that the system could produce dusts with 23 μm mass median aerodynamic diameter (MMAD) at levels up to ≥1200 mg/m 3. To validate system utility, F344 rats were exposed for 2 h to ≈100 mg WTC dust/m 3. Exposed rats had significantly increased lung weight and levels of select tracer metals 1 h after exposure. Using this system, it is now possible to conduct relevant inhalation exposures to determine adverse WTC dusts impacts on the respiratory system. Furthermore, this novel integrated Fishing Line-ITIH system could potentially be used in the analyses of a wide spectrum of other dusts/pollutants of sizes previously untested or delivered to the lungs in ways that did not reflect realistic exposure scenarios.

AB - First responders (FRs) present at Ground Zero within the critical first 72 h after the World Trade Center (WTC) collapse have progressively exhibited significant respiratory injury. The majority (>96%) of WTC dusts were >10 μm and no studies have examined potential health effects of this size fraction. This study sought to develop a system to generate and deliver supercoarse (10-53 μm) WTC particles to a rat model in a manner that mimicked FR exposure scenarios. A modified Fishing Line generator was integrated onto an intratracheal inhalation (ITIH) system that allowed for a bypassing of the nasal passages so as to mimic FR exposures. Dust concentrations were measured gravimetrically; particle size distribution was measured via elutriation. Results indicate that the system could produce dusts with 23 μm mass median aerodynamic diameter (MMAD) at levels up to ≥1200 mg/m 3. To validate system utility, F344 rats were exposed for 2 h to ≈100 mg WTC dust/m 3. Exposed rats had significantly increased lung weight and levels of select tracer metals 1 h after exposure. Using this system, it is now possible to conduct relevant inhalation exposures to determine adverse WTC dusts impacts on the respiratory system. Furthermore, this novel integrated Fishing Line-ITIH system could potentially be used in the analyses of a wide spectrum of other dusts/pollutants of sizes previously untested or delivered to the lungs in ways that did not reflect realistic exposure scenarios.

KW - Dust

KW - Fishing line

KW - Generator

KW - Intratracheal inhalation

KW - World Trade Center

KW - WTC

UR - http://www.scopus.com/inward/record.url?scp=84890797740&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84890797740&partnerID=8YFLogxK

U2 - 10.1038/jes.2013.68

DO - 10.1038/jes.2013.68

M3 - Article

VL - 24

SP - 105

EP - 112

JO - Journal of Exposure Science and Environmental Epidemiology

JF - Journal of Exposure Science and Environmental Epidemiology

SN - 1559-0631

IS - 1

ER -