T1 - A left ventricular end-diastolic dimension less than 6.0 cm is associated with mortality after implantation of an axial-flow pump
AU - Kawabori, Masashi
AU - Kurihara, Chitaru
AU - Conyer, Ryan
AU - Sugiura, Tadahisa
AU - Critsinelis, Andre C.
AU - Lee, Vei Vei
AU - Civitello, Andrew B.
AU - Morgan, Jeffrey A.
N1 - Publisher Copyright:
© 2019
PY - 2019/6
Y1 - 2019/6
N2 - Objective: The effects of having a lower left ventricular end-diastolic dimension before HeartMate II (Thoratec Corp, Pleasanton, Calif)left ventricular assist device implantation remain unclear. We analyzed our single-center data on HeartMate II implantation to determine whether having a lower left ventricular end-diastolic dimension preoperatively was associated with inferior outcomes. Methods: From November 2003 to March 2016, 393 patients with chronic heart failure underwent primary HeartMate II implantation. We compared the preoperative left ventricular end-diastolic dimension and associated survival outcomes of these patients to determine the left ventricular end-diastolic dimension cutoff for worse overall survival. Then, we compared the preoperative demographics, stroke rate, and mortality of patients with a left ventricular end-diastolic dimension above the cutoff for worse survival with those of patients with a left ventricular end-diastolic dimension below the cutoff. Results: A Cox multivariate regression model showed that low left ventricular end-diastolic dimension was an independent predictor of mortality (hazard ratio, 1.49; P =.02). The Contal and O'Quigley method showed that overall survival postimplantation was decreased in patients with a left ventricular end-diastolic dimension less than 6.0 cm (n = 91). Kaplan–Meier analysis confirmed that the left ventricular end-diastolic dimension less than 6.0 cm group had lower overall survival than the left ventricular end-diastolic dimension 6.0 cm or greater group (P =.04). Furthermore, a competing-risk analysis showed that postoperative stroke was more common in the left ventricular end-diastolic dimension less than 6.0 cm group than in the left ventricular end-diastolic dimension 6.0 cm or greater group (P <.01). Conclusions: Overall survival was decreased and postoperative stroke was increased in HeartMate II recipients with a preoperative left ventricular end-diastolic dimension less than 6.0 cm. Future research should determine the left ventricular end-diastolic dimension cutoff values for safely implanting other support devices, and device designs should be improved to better accommodate the needs of patients with a limited left ventricle size.
AB - Objective: The effects of having a lower left ventricular end-diastolic dimension before HeartMate II (Thoratec Corp, Pleasanton, Calif)left ventricular assist device implantation remain unclear. We analyzed our single-center data on HeartMate II implantation to determine whether having a lower left ventricular end-diastolic dimension preoperatively was associated with inferior outcomes. Methods: From November 2003 to March 2016, 393 patients with chronic heart failure underwent primary HeartMate II implantation. We compared the preoperative left ventricular end-diastolic dimension and associated survival outcomes of these patients to determine the left ventricular end-diastolic dimension cutoff for worse overall survival. Then, we compared the preoperative demographics, stroke rate, and mortality of patients with a left ventricular end-diastolic dimension above the cutoff for worse survival with those of patients with a left ventricular end-diastolic dimension below the cutoff. Results: A Cox multivariate regression model showed that low left ventricular end-diastolic dimension was an independent predictor of mortality (hazard ratio, 1.49; P =.02). The Contal and O'Quigley method showed that overall survival postimplantation was decreased in patients with a left ventricular end-diastolic dimension less than 6.0 cm (n = 91). Kaplan–Meier analysis confirmed that the left ventricular end-diastolic dimension less than 6.0 cm group had lower overall survival than the left ventricular end-diastolic dimension 6.0 cm or greater group (P =.04). Furthermore, a competing-risk analysis showed that postoperative stroke was more common in the left ventricular end-diastolic dimension less than 6.0 cm group than in the left ventricular end-diastolic dimension 6.0 cm or greater group (P <.01). Conclusions: Overall survival was decreased and postoperative stroke was increased in HeartMate II recipients with a preoperative left ventricular end-diastolic dimension less than 6.0 cm. Future research should determine the left ventricular end-diastolic dimension cutoff values for safely implanting other support devices, and device designs should be improved to better accommodate the needs of patients with a limited left ventricle size.
KW - heart failure
KW - left ventricular assist device
KW - neurological dysfunction
KW - small left ventricle
UR - http://www.scopus.com/inward/record.url?scp=85061727961&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85061727961&partnerID=8YFLogxK
U2 - 10.1016/j.jtcvs.2019.01.015
DO - 10.1016/j.jtcvs.2019.01.015
M3 - Article
C2 - 30797583
AN - SCOPUS:85061727961
SN - 0022-5223
VL - 157
SP - 2302
EP - 2310
JO - Journal of Thoracic and Cardiovascular Surgery
JF - Journal of Thoracic and Cardiovascular Surgery
IS - 6
ER -